Sollae SIG-5440 Bedienungsanleitung

SIG-5440 User Manual Ver. 1.1
- 1 -
https://www.ezTCP.com
This symbol, found on your product or on its packaging, indicates that
this product should not be treated as household waste when you wish to
dispose of it. Instead, it should be handed over to an applicable collection
point for the recycling of electrical and electronic equipment. By ensuring
this product is disposed of correctly, you will help prevent potential negative
consequences to the environment and human health, which could otherwise be caused by
inappropriate disposal of this product. The recycling of materials will help to conserve
natural resources. For more detailed information about the recycling of this product,
please contact your local city office, household waste disposal service or the retail
store where you purchased this product.

SIG-5440 User Manual Ver. 1.1
- 2 -
https://www.ezTCP.com
Contents
1Overview .......................................................- 4 -
1.1 Introduction ........................................................ - 4 -
1.2 Features ............................................................ - 4 -
1.3 Specification ....................................................... - 5 -
1.4 Interface ........................................................... - 6 -
1.4.1 Power .................................................................. - 6 -
1.4.2 Ethernet ............................................................... - 7 -
1.4.3 Digital Input Port ..................................................... - 7 -
1.4.4 LED ................................................................... - 11 -
1.4.5 Function Button ....................................................... - 12 -
1.4.6 Setup Port ............................................................ - 12 -
2Preparation ...................................................- 13 -
2.1 Installing the Setting Tool ........................................ - 13 -
2.2 Connecting a Product ............................................... - 13 -
2.3 Searching Devices .................................................. - 13 -
2.4 Logging in ......................................................... - 13 -
3Settings ......................................................- 14 -
3.1 Network ............................................................ - 14 -
3.1.1 Obtain an IP address automatically..................................... - 14 -
3.1.2 Use a Static IP address................................................ - 15 -
3.2 General ............................................................ - 16 -
3.2.1 Comments .............................................................. - 16 -
3.2.2 TCP ................................................................... - 16 -
3.2.3 Modbus ................................................................ - 17 -
3.2.4 Digital Input ......................................................... - 17 -
3.3 Security ........................................................... - 18 -
3.3.1 Password .............................................................. - 18 -
3.3.2 Certificate ........................................................... - 18 -
3.3.3 spFinder .............................................................. - 18 -
3.3.4 Client ID ............................................................. - 19 -
4Management ....................................................- 20 -
4.1 Checking Status .................................................... - 20 -
4.1.1 Product Information ................................................... - 20 -
4.1.2 Communication Status .................................................. - 21 -
4.1.3 Timeout ............................................................... - 22 -
4.1.4 Copy status ........................................................... - 22 -
4.2 Firmware Change .................................................... - 23 -
4.2.1 Online Upgrade ........................................................ - 23 -
4.2.2 Manual Upgrade ........................................................ - 24 -

SIG-5440 User Manual Ver. 1.1
- 3 -
https://www.ezTCP.com
4.3 Console ............................................................ - 25 -
4.3.1 Output Tab ............................................................ - 25 -
4.3.2 FW Log Tab ............................................................ - 26 -
4.3.3 Timeout ............................................................... - 26 -
4.4 Export/Import Setting Values ....................................... - 26 -
4.5 Factory Reset ...................................................... - 27 -
5Register Map ..................................................- 28 -
5.1 Read Only .......................................................... - 28 -
5.1.1 Digital Input Status Register.......................................... - 28 -
5.1.2 Inverted Digital Input Status Register................................. - 28 -
5.1.3 Digital Input Counter Register......................................... - 28 -
5.1.4 Device Information Register............................................ - 29 -
5.2 Read / Write ....................................................... - 30 -
5.2.1 Reset Digital Input Counter Register................................... - 30 -
5.2.2 Activating DI Status Change Notification Register...................... - 30 -
6Technical Support and Warranty ................................- 31 -
6.1 Technical Support .................................................. - 31 -
6.2 Warranty ........................................................... - 31 -
6.2.1 Free Repair Services .................................................. - 31 -
6.2.2 Charged Repair Services................................................ - 31 -
7Precaution and Exemption from Liability .......................- 32 -
7.1 Precaution ......................................................... - 32 -
7.2 Exemption from Liability ........................................... - 33 -
7.2.1 English version ....................................................... - 33 -
7.2.2 French version ........................................................ - 34 -
8Revision History ..............................................- 36 -

SIG-5440 User Manual Ver. 1.1
- 4 -
https://www.ezTCP.com
1 Overview
1.1 Introduction
SIG-5440 is an industrial I/O Gateway consisting of 4 digital input ports. Users
can remotely monitor digital values of sensors connected to this product by using
Modbus/TCP.
1.2 Features
⚫4 digital input ports: Wet Contact or Dry Contact input
⚫Support counter function on digital input ports
⚫Support Modbus/TCP
⚫Support multiple TCP connection (Max. 4 channels)
⚫Support the
Internet Switch
⚫Industrial temperature range (-40℃ ~ +85℃)
Internet Switch: A configuration that connects devices to each other without an
HMI to transmit digital signals in both directions

SIG-5440 User Manual Ver. 1.1
- 5 -
https://www.ezTCP.com
1.3 Specification
Digital Input
Input Type
Dry Contact / Wet Contact / NPN / PNP
Input Voltage Range
4.5V ~ 25V
Number of Ports
4 ports
Network Physical Interface
Network Interface
10Base-T/100Base-TX Ethernet (RJ45)
Ethernet Speed Auto Sense
1:1 or Cross-over Cable Auto Sense
Software Functions
Protocols
IPv4/IPv6 Dual Stack,
TCP/UDP, ICMP, DHCP, mDNS, Modbus/TCP, SSL/TLS
Indicators
LED
MTX, MRX, Di0, Di1, Di2, Di3
Management
spFinder
Configuration and Monitoring Tool
Security
Password
Dimension
Size
94mm x 57mm x 23mm
Weight
about 65g
Operating Environment
Input Voltage
DC5V±0.5V
Protection
Reverse Voltage Protection / Surge Protection
Current Consumption
typically, 150mA
Operating Temperature
-40℃ ~ +85℃
Storage Temperature
-40℃ ~ +85℃
Certificate
KC
Registration (KN 32, KN 35)
CE
EMC 2014/30/EU, RoHS 2011/65/EU
FCC
FCC Part 15 Subpart B, Class A
Table 1-1 Specification

SIG-5440 User Manual Ver. 1.1
- 7 -
https://www.ezTCP.com
1.4.2 Ethernet
SIG-5440 provides 10/100Mbps Ethernet. The pin assignment is as follows:
Figure 1-3 Ethernet
1.4.3 Digital Input Port
This port is interfaced with a 3.5mm pitch 6-pole terminal block.
Figure 1-4 Digital Input Port
⚫Port Specification
Division
Value
Number of ports
4
Maximum Input Voltage
DC 25V
Voltage Required for ON decision
higher than DC 4.5V
Voltage for OFF decision
lower than DC 1V
Table 1-2 Port Specification
Inhaltsverzeichnis
Andere Sollae Tor Handbücher
Beliebte Tor Handbücher anderer Marken

LST
LST M500RFE-AS Bedienungsanleitung

Kinnex
Kinnex Media Gateway Bedienungsanleitung

2N Telekomunikace
2N Telekomunikace 2N StarGate Bedienungsanleitung

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Bedienungsanleitung

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Bedienungsanleitung

Telsey
Telsey CPVA 500 - SIP Bedienungsanleitung