SOLUXTEC Das modul Mono XSC Bedienungsanleitung

USER GUIDE
SOLUXTEC SOLAR
PRODUCTS

2
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
1. INTRODUCTION 3
2. BASIC SAFETY INSTRUCTIONS 3
3. REGULATION 4
4. TRANSPORT AND HANDLING 4
5. PRODUCT DETAILS 5
6. INSTALLATION 6
Modules Design 6
Precaution 13
Installation Option 15
7. ELECTRICAL INSTALLATION 13
Precaution 18
Wiring 18
8. MAINTENANCE AND CLEANING 21

3
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
1 INTRODUCTION
Thank you for electing SOLUXTEC GmbH PV modules. The following user guide is covering
important points to be read and understood before installation of SOLUXTEC products. This
document is not having any aims in relation to quality warranties but only for safety, electrical,
mechanical and general handling of SOLUXTEC products.
In case a pv installation is not respecting above mentioned points, the quality warranty of
SOLXTEC product will become invalid.
This document belongs to SOLUXTEC, all contents are SOLUXTEC intellectual properties.
SOLUXTEC reserves the right to modify this document without prior notice.
- Please read this document carefully before installation
- Please make sure that this document is always available for installers and operators to
handle SOLUXTEC’s products.
- Please give a copy of this document to the installation owner.
- If any questions are not well answered in this document, please contact SOLUXTEC
support prior installation.
2 SAFETY
The installation of photovoltaic modules must respect the current standards from the
place of installation. It is imperative to refer to the standards of each local authority
in case specifics rules are imposed.
Installation of photovoltaic modules must be operated by qualified peoples, knowing
and respecting all regulation and requirements for compliance with country of
installation.
Solar modules create DC electricity and are even energized under a slight
illumination level. Several modules connected together may occur an accumulation
of voltage and intensity. Please respect all personal security to avoid a risk of
electrocution.
Please respect the data given from the elected module’s data sheet to respect all
module’s limits and comply with other materials that will be need to operate the
photovoltaic generator.
- Never open the junction box on the back of the photovoltaic module
- Make sure that connectors are clean and not dirty or wet before connection.
- Never disconnect the photovoltaic connector under load. Always turn off the DC breaker
prior any photovoltaics connector disconnection.
- Tools must be dedicated for solar installation and supporting DC current.
- The final photovoltaic generator must follow all needed standard and requirement in
compliance with the installation country (PV, inverter, cable, grounding and other
accessories from the pv generator).
- Never disassembled any part of the module.

4
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
3 REGULATION
All modules presented in this document are covered from the following standards:
IEC 61215
IEC 61730
IEC 62804 (PID)
IEC 61701 (SALT MIST)
IEC 62716 (AMMONIA)
EMC and Low Voltage regulation
NOTE: As SOLUXTEC is always improving his products. Please contact your customer service
if a standard is missing for your project from above list.
4 TRANSPORT AND HANDLING
During transportation and Interim storage, following point have to be respected:
Transportation of the modules need to be done only with SOLUXTEC original
packaging.
Never exceed the maximum number of pallets to be stacked. Only original SOLUXTEC
packaging may allow pallet stacking.
When unpacking modules from the packaging, please wear soft and clean gloves. It is
forbidden to use suction cup to carry the module as it will damage the anti-reflective
coating for the solar glass.
It is forbidden to carry/lift the modules from the solar cables or from the junction box or
any conductive elements.
Do not drop module directly on module.
By handling modules be cautious especially on the corners to not shock them.
By handling the modules, never scratch the anodised coating of the frame.
Corrosion may occur and brings to a mechanical resistance diminution.
It is forbidden to drill holes in the aluminium frames.
It is forbidden to paint the modules or to apply any adhesive on the module’s surface.
Never walk on the module.

5
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
5 PRODUCTS DETAILS
This document is valid for all products above:
cell type availability reference Type Variante colours
Das modul Mono XSC Perc M10 until 2023 DMMXSC glass foil framed Anti Glare
/ AC black, white
Das modul Mono XSC Pure
Glass Perc M10 until 2023 DMMXSC_PG glass glass Bifacial framed AC black,
transparent
PowerSlate Mono XSC Perc M10 until 2023 PSMXSC glass foil frameless na black
Das Modul Mono XSC Ninside Ntype M10 from 2023 DMMXSCNi glass foil framed Anti Glare
/ AC black, white
Das Modul Mono XSC Ninside
Pure Glass Ntype M10 from 2023 DMMXSCNi_PG glass glass Bifacial framed AC black,
transparent
PowerSlate Mono XSC
Ninside Ntype M10 from 2023 PSMXSCNi glass foil frameless na black
Das Modul Mono Alpine XSC
Ninside Ntype M10 from 2023 DMMAXSCNi glass foil framed AC black, white
Das Modul Mono Alpine XSC
Ninside Pure Glass Ntype M10 from 2023 DMMAXSCNi_PG glass glass Bifacial framed AC black,
transparent
PowerSlate Mono Alpine XSC
Ninside Pure Glass Ntype M10 from 2023 PSMAXSCNi_PG glass glass Bifacial frameless na transparent
Label explanation:
All Module Type from SOLUXTEC is having his own label
on back.
This label is summarizing the module data sheet as follow:
- Place of production
- Commercial name
- STC (standard test condition) data:
- Pmpp : Power in watt at maximum power point
- Isc : Short circuit Intensity in ampere
- Impp : Intensity in ampere at power point
- Voc : Voltage in volt in open circuit
- Vmpp : Voltage in volt at power point
- EAN 13 code
For more details about mechanical or electrical module behaviour, please refer to dedicated
data sheet.
Serial number codification:
S T U V WW XX YYY ZZZZ, where:
- S = D for DAS MODUL
P for POWERSLATE
- T = F for foil module 108 cells
G for glass glass module 108 cells
H for foil Module 90 cells
I for glass glass module 90 cells
J for foil module Anti-glare 108 cells
- U = I Perc Half cut mono M10
N Half cut mono Topcon M10
- V = 1 for production in FAB 1 Bitburg
2 for production in FAB 2 Trier
- W = month of production
- X = year of production
- Y = Production order number
- Z = Module number from above Production
Order number.

6
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
6 INSTALLATIONS ON SITE
SOLUXTEC pv modules installation need to respect the following guidelines on site.
MODULE DESIGN PRESENTATION
a) DAS MODUL MONO XSC (DMMXSC)
Mono perc M10 half cut
(all values are given in mm)
Frame section (double section):
: 4 grounding holes
Maximum load test: + 5400 Pa // - 2400 Pa
1133
1722
35
: 4 mounting holes
306 78

7
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
b) DAS MODUL MONO XSC Ni (DMMXSCNi)
Mono ntype M10 half cut TOPCON
(all values are given in mm)
Frame section:
: 4 grounding holes
Maximum load test: + 5400 Pa // - 2400 Pa
1133
1722
: 4 mounting holes
306 78
30
New cells Ntype Topcon
New Frame with stronger alloy
New plastic corner unbreakable

8
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
c) DAS MODUL MONO XSC Ni Pure Glass (DMMXSCNi_PG)
Mono ntype M10 half cut TOPCON GLASS GLASS
(all values are given in mm)
Frame section:
: 4 grounding holes
Maximum load test: + 8100 Pa // - 2400 Pa
1133
1722
: 4 mounting holes
306 78
30
New cells Ntype Topcon
New Frame with stronger alloy
New plastic corner unbreakable
Bifaciality 0,8

9
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
d) DAS MODUL MONO Alpine XSC Ni (DMMAXSCNi)
Mono ntype M10 half cut TOPCON 90 cells
(all values are given in mm)
Frame section:
: 4 grounding holes
Maximum load test: + 5400 Pa // - 2400 Pa
967
1722
: 4 mounting holes
306 78
30
New cells Ntype Topcon
New Frame with stronger alloy
New plastic corner unbreakable
Easy to carry

10
SOLUXTEC USER GUIDE 2023_Version 2/a_ALL RIGHTS RESERVED
e) DAS MODUL MONO Alpine XSC Ni Pure Glass (DMMAXSCNi_PG)
Mono ntype M10 half cut TOPCON 90 cells GLASS GLASS
(all values are given in mm)
Frame section:
: 4 grounding holes
Maximum load test: + 8100 Pa // - 2400 Pa
967
1722
: 4 mounting holes
306 78
30
New cells Ntype Topcon
New Frame with stronger alloy
New plastic corner unbreakable
Bifaciality 0,8
Easy to carry
Dieses Handbuch passt für folgende Modelle
19
Inhaltsverzeichnis
Andere SOLUXTEC Solarpanel Handbücher