Sonetonix LC-RL-8-R Bedienungsanleitung

User Manual
LC-RL-8-R
Sonetonix Rack Mount RELAY Controller

LC-RL-8-R User Manual
Sonetonix
Preface
Read this user manual carefully before using this product. Pictures shown in this manual is
for reference only, different model and specifications are subject to real product.
This manual is only for operation instruction only, not for any maintenance usage. The
functions described in this version are updated till January 2016. Any changes of functions
and parameters since then will be informed separately. Please refer to the dealers for the
latest details.
Trademarks
Product model and its logo are trademarks. Any other trademarks mentioned in this manual
are acknowledged as the properties of the trademark owner. No part of this publication may
be copied or reproduced without prior written consent.
FCC Statement
This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. It has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a commercial installation.
Operation of this equipment in a residential area is likely to cause interference, in which case
the user at their own expense will be required to take whatever measures may be necessary
to correct the interference
Any changes or modifications not expressly approved by the manufacture would void the
user’s authority to operate the equipment.

LC-RL-8-R User Manual
Sonetonix
SAFETY PRECAUTIONS
To insure the best from the product, please read all instructions carefully before using the
device. Save this manual for further reference.
Unpack the equipment carefully and save the original box and packing material for
possible future shipment
Follow basic safety precautions to reduce the risk of fire, electrical shock and injury to
persons.
Do not dismantle the housing or modify the module. It may result in electrical shock or
burn.
Using supplies or parts not meeting the products’ specifications may cause damage,
deterioration or malfunction.
Refer all servicing to qualified service personnel.
To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this
product near water.
Do not put any heavy items on the extension cable in case of extrusion.
Do not remove the housing of the device as opening or removing housing may expose
you to dangerous voltage or other hazards.
Install the device in a place with fine ventilation to avoid damage caused by overheat.
Keep the module away from liquids.
Spillage into the housing may result in fire, electrical shock, or equipment damage. If an
object or liquid falls or spills on to the housing, unplug the module immediately.
Do not twist or pull by force ends of the optical cable. It can cause malfunction.
Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the
device before cleaning.
Unplug the power cord when left unused for a long period of time.
Information on disposal for scrapped devices: do not burn or mix with general household
waste, please treat them as normal electrical wastes.

LC-RL-8-R User Manual
Sonetonix
Contents
1. PRODUCT OVERVIEW...................................................................................................................................1
1.1 Key Features...............................................................................................................................1
1.2 Override Input............................................................................................................................. 2
1.3 Front panel...................................................................................................................................2
1.4 Loads............................................................................................................................................2
1.5 S-NET...........................................................................................................................................2
2. TECHNICAL SPECIFICATIONS.................................................................................................................... 3
2.1 RELAY Controller Electrical Specifications............................................................................ 3
2.2 Power Requirements................................................................................................................. 3
2.3 Connections.................................................................................................................................3
2.4 Controls and Indications............................................................................................................3
2.5 Mechanical specifications......................................................................................................... 4
2.5.1 Enclosure..............................................................................................................................4
2.5.2 Environmental......................................................................................................................4
2.5.3 Dimensions and weight...................................................................................................... 4
3. APPLICATION AND WIRING DIAGRAM.................................................................................................... 5
4. MANUAL CONTROL........................................................................................................................................6
4.1 Programming the S-NET ID......................................................................................................6
4.2 Changing the Channel level / status........................................................................................6
5. S-NET COMMUNICATION............................................................................................................................. 7
5.1 Communication parameters......................................................................................................7
5.2 S-NET Commands..................................................................................................................... 7
5.3 Examples..................................................................................................................................... 8
6. TROUBLESHOOTING.....................................................................................................................................8
7. AFTER-SALES SERVICE............................................................................................................................. 10

LC-RL-8-R User Manual
Sonetonix 1
1. Product Overview
Sonetonix LC-RL-8-R, Relay module
incorporates 8ch relays that can be connected to
control controllable devices. The RELAY
controller can be interfaced Using our Touch
Keypads or Android App to control from
anywhere in the room. Four channels of Relay
controller can be used in non-dimmable lighting
control, screen control, Water fountain
motor control (up to 0.5Hp motor),
Gate/Shutter control and etc. Maximum of
10A load can be connected to each channel.
Provision to store and re-call up to 16 pre-
set scenes. As with other Sonetonix
products, all S-NET commands are
available to use and program the Device as
per user needs thus extending its
functionality.
1.1 Key Features
- 8 Channels RELAY Controller, standard type @10A per channel
- Power switching
- Used in non-dimmable lighting control, screen control (up to 0.5Hp motor) etc.
- Supports 16 scenes with internal memory
- Low voltage control interface for each channel
- Restores channel status upon power reset
- Configurable START time for each channel, allows to set delay to start the switching
at required time
- S-NET ID programming sequence with front panel switches to set the Device’s S-
NET ID manually
- Front panel switches to operate each channels manually
- Watchdog LED on front panel blinking @1 sec Indicates normal working condition of
the Device
- Status indication LEDS for each channel
- S-NET Communication, using S-NET protocol enables the relay Controller to be
connected with other SONETONIX Lighting/ Dimming modules for a complete
Automation Solution
- Easy installation with Wall mounting
Fig 1 LC-RL-8-R, Rack Mount 8 channel RELAY
Controller

LC-RL-8-R User Manual
Sonetonix 2
1.2 Override Input
An override input is provided to allow an external contact closure to momentarily
override the control system program and set all channels output to its override pre-set state.
1.3 Front panel
Four tactile switches on the front panel provide two functionalities. One, the Device’s
S-NET id can be programmed manually at any time, using the CH1 (1) and CH2 (2) keys.
The other functionality of these switches is to navigate through the channels manually along
with channel status indication LEDS.
1.4 Loads
Two pin detachable terminal blocks on the rear side for each channel to control the
controllable devices. Live IN (230VAC Mains @50hz) to be connected on Pin 1 and Live
output to be taken from Pin 2 and connect to Load Live.
1.5 S-NET
The LC-RL-8-R communicates with all Sonetonix products or third party units via S-NET. A
pair of S-NET terminal blocks, allow for easy daisy-chaining of several DIN rail Series
automation control modules. 12VDC, S+, S- and Ground should be connected in each S-
NET terminal

LC-RL-8-R User Manual
Sonetonix 3
2. Technical Specifications
2.1 RELAY Controller Electrical Specifications
Parameter
Value
Unit
Operating Voltage(@50hz)
220-240
VAC
Max Power per channel
2300
W
Max Load current per channel
10
A
Module Total current
80
A
Operating Temperature
0 – 45
°C
Table1. Relay controller Electrical specifications
2.2 Power Requirements
S-NET Power Usage:6 Watt (0.5A @12Volts)
2.3 Connections
CHANNELS (1-8): (4) 2-pin 5.08 mm detachable terminal blocks with SPST relay switch
circuit @10A per channel
LV TRIGGERS (G, 1-8): (1) 5-pin 5.08mm detachable terminal block to provide low voltage
trigger to each channel
S-NET: (1) 4-pin 5.08mm detachable terminal blocks for S-NET communication
2.4 Controls and Indications
PWR: (Red) Illuminates when DC power is applied on S-NET
WDT: (Green) Blinking @ 1 sec Indicates normal working condition of the Device
COM: (Orange) Blinks during S-NET communication
CH1 TO CH8: (Red) Channel status indication LEDs
1-8: Miniature tactile switches to set S-NET ID or control channels manually

LC-RL-8-R User Manual
Sonetonix 4
2.5 Mechanical specifications
2.5.1 Enclosure
Rack Mount dark Gray metal sheet enclosure
2.5.2 Environmental
Operating Temperature: 0° to 45°C
2.5.3 Dimensions and weight
Parameter
Value
Unit
Height
7.02
Inches
Width
17
Inches
Depth
1.98
Inches

LC-RL-8-R User Manual
Sonetonix 5
3. Application and wiring diagram

LC-RL-8-R User Manual
Sonetonix 6
4. Manual Control
4.1 Programming the S-NET ID
For any communication to take place with the LC-RL-8-R, it needs to be programmed
with a unique S-NET ID (1 to 230).
The S-NET ID can be set manually using the following procedure
Step 1: Press and hold the (1) Setup switch on front panel for 5 seconds
Step 2: The Watch dog LED stops blinking and the device enters in to programming mode
Step 3: The default S-NET ID will be displayed in terms of WDT LED blinking sequence.
Step 4: Press the (2) switches on front panel to set the S-NET ID number
Step 5: After choosing a suitable ID, press the (1) Set up Switch to enter in to normal mode,
the watchdog LED will flash a blinking sequence and enter in to Normal mode.
4.2 Changing the Channel level / status
Front panel 8 switches for control and configure the load status manually. Each
channel’s ON / OFF status is indicated on the Front panel LEDS
The load status for any channel can be changed manually by pressing corresponding tactile
switch.
Inhaltsverzeichnis
Andere Sonetonix Controller Handbücher