Sparmax PR968 Series Bedienungsanleitung

Instruction Manual of PR968X Model Controller
- 1 -
Controller for massage bathtub
PR9681 PR9681M PR9683 PR9683M
Before using, please read it carefully.
Safety
Danger symbol:This icon reminds the users that this product has
dangerous voltage!
Warning symbol:This icon reminds the users that this product is
enclosed with important operating and maintenance instruction!
【Warning】
1. In order to prevent fire or electric shock accident, do not expose the controller to
the rain or humid environment. There are dangerous high-tension fittings
inside the controller, therefore do not open the cover. Entrust the repairing
work only to the qualified professional repairing personnel when repairing is
required.
2. Without the clear approval from the controller manufacturer or its authorized
units, any change or alternation to this controller might bring various
inconveniences to the users when in use.
【Attention】
1. Please read this operating instruction manual thoroughly, so as to allow you
to master the correct use of this controller.
2. After reading this operating instruction manual, please keep it safe and for

Instruction Manual of PR968X Model Controller
- 2 -
reference in the future. If repairing is required, please contact the local dealer
or the technical service center of our company.
【Notice for use】
1. In case this controller is not used for a long time, please remove the power
plug from the socket.
2. Before switching on the power, please make sure that all wirings and power
cord have been connected accurately.
3. Please put this controller in a ventilated dry area. Prevent it from getting close
to the heat source, put it away from direct sunlight, mechanical vibration,
dampness and dusty environment, and prevent it from getting close to other
thermal-radiating objects.
【Helpful suggestion】
1. In order to prolong the service life of this controller, the time interval for
continuously turning on and off the machine must be over 30 seconds.
2. Please switch off the power after use.
3. The power supply used must be consistent with the voltage specified value
indicated on this controller; otherwise it will not work, or even burn out the
controller.
4. When installing this controller, carefully check if the load parameters are
consistent with the parameters required by this controller, otherwise it will not
work, or even burn out the controller.
5. If it is halted accidentally, please close and restart.

Instruction Manual of PR968X Model Controller
- 3 -
I、 Brief Introduction
1. General Description of Functions
Model
Functions PR9681 PR9681M PR9683 PR9683M
1. LOCK √ √ √ √
2. PUMP √ √ √ √
3. BLOWER √ √ √ √
4. Thermostatic Heating √ √
5. TEMPRETURE SENSOR √ √
6. LAMP √ √ √ √
7. FM DIGITAL TURNNING RADIO √ √ √ √
8. PLAY CD PROGRAM √ √
9. MP3 √ * √
10.
WATER LEVEL DETECTION √ √ √ √
11.
OZONE * * * *
12.
CLEANNING * * * *
13.
REMOTE CONTROL √
√ √ √
√:with this function; X: without this function; *:optional function
2. Controller System Including:
1) Control panel(1);
2) Control electric box(1).
3) Remote (1).
3. Characteristics of the Controller
1) Rated voltage :AC220V-240V
2) Working voltage range:AC200V-248V
3) Rated power :50HZ/60HZ
4) Controllable current: <25A
5) Power consumption:<10W (all loads OFF)
6) Applied ambient temperature :+5℃ ~ +40℃
4. Devices controlled by the controlling system
1) Pump :AC220V/2HP
2) Themostatic heating : AC220V/2000W
3) Blower : AC220V/1HP
4) Lamp : AC12V/20W
5) Ozone generator : AC12V/6W
6) Solenoid : DC12V/5W
7) Loudspeaker : 8Ω/10W
5. The LCD shows the following information

Operation instruction manual of model:PR968x
- 4 -
6. Schematic Diagram of control panel
Power switch
Function confirm
Function switch
Choose upward
Choose downward
7. Schematic Diagram of Remote
Power switch
Volume - Volume +
Frequency - Frequency +
Station storage / select
FM Radio
Blower
Pump Lamp
Ozone
AUDIO
PR9681

Operation instruction manual of model:PR968x
- 5 -
Power switch
Volume - Volume +
Adjust - Adjust +
Frequency storage / select
FM radio Audio
Blower
Function switch
Pump Lamp
Ozone
Theomostatic heating
FM Radio
Pump
Frequency - Frequency +
Lamp
Power switch
Volume - Volume +
Station storage / select

Operation instruction manual of model:PR968x
- 6 -
II、 Operation of Control Panel
1 The panel is with inducing function, the duration of the touch is about
0.5 s. When any function button works, there is a sound of “di…”
2 Power Switch
Press “ ”to turn on the controller, lamp is turned on;press again to
turn off the controller and turn off all the functions.
3 Lamp
When the system is on,press “ 、” to choose the Light
function,when cursor select “Light”,press“ ” to turn on the light,
light icon on LCD blinks, press“ ” again to turn off the light,light
icon stops blink.
4 Lock
4.1 If no operation with the control panel for 1 minute,all the keys
will be locked, “LOCK”displays on LCD;press any key for 3
seconds to unlock the keys.
5 Ozone
5.1 When the system is on,press “ 、” to choose the OZONE
function,when cursor select “Ozone”,press“ ” to turn on the
ozone,ozone icon on LCD blinks, press“ ” again to turn off
the ozone,ozone icon stops blink.
5.2 Ozone function works for 10 minutes and then it will stops

Operation instruction manual of model:PR968x
- 7 -
automatically.
6 Blower
6.1 When the system is on,press “ 、” to choose the BLOWER
function,when cursor select “Blower”,press“ ” to turn on the
blower,Blower icon on LCD blinks, press“ ” again to turn off
the blower,blower icon stops blink.
7 PUMP
7.1 The water checking device of this controller protects the water
pump from burning out.
7.2 When the system is on,press “ 、” to choose the PUMP
function,when cursor select “Pump”,press“ ” to turn on the
pump,pump icon on LCD blinks, press“ ” again to turn off the
pump,pump icon stops blink.
7.3 When the water level lower than the setting value, pump will not
work.
7.4 When the pump is working and the water level sensor checks
the water level lower than the setting value,pump stops working
automatically,pump icon on LCD blinks.If any time the level
sensor checks the water level achieves the setting value, pump
will work automatically.
8 Theomostatic Heating
8.1 This functions works only when the water pump surf function is

Operation instruction manual of model:PR968x
- 8 -
on.
8.2 When the system is on,press “ 、” to choose the HEAT
function,when cursor select “Heat”,press“ ” to turn on the
heater:
8.2.1 2 Thermostatic heating function starts or stops according to
the temperature(the temperature that the system defaults is
37oC):
Controlling rule is as follows:
If the temperature≥setting temperature+1℃,stop heating;
If the temperature≤setting temperature -1℃,start heating.
8.3 Press “ ” again to turn off the heater.
8.4 Temperature adjustment
8.4.1 When the thermostatic heating function is on, press till
temperature valueblinks,then press “ ” or“ ” once ,
temperature shall be increased or decreased 1 ℃ ; if
press“ ”or“ ”over 2 seconds,temperature will increased
or decreased at the speed“1℃ /0.5 s”;without any operation
for 5 seconds, LCD will display the water temperature.
8.5 Temperature setting range:30℃--45℃.
8.6 When the temperature sensor error, LCD shows “E1” and the
buzzer sounds : di…di…,thermostatic heating function will not
work.

Operation instruction manual of model:PR968x
- 9 -
9 FM digital turnning radio
9.1 The FM frequency scope is 87.5MHz—108.0MHz.
9.2 When the system is on,press“ 、” till cursor select “Music”,
press“ ” to turn on the FM radio, LCD displays the present
frequency and“FM”;then press “ ” again to turn off the FM
radio,the present frequency and“FM” will not show on LCD.
9.3 When the FM radio is on,press“ ” till “FM”and“ MHZ” on LCD
blinks to adjust the frequency:
9.3.1 Press“ ” to increase the length of one step (the length of
one step =100KHz): Press this button over 2 seconds, the
system searches the radio stations of larger frequencies
automatically; the digital phase locked loop will lock the FM
station automatically and the LCD shows the present
frequency, when it reaches to the limit of 108.0MHz, press
this button again and the frequency jumps to 87.5MHz.
9.3.2 Press“ ” to decrease the length of one step (the length of
one step =100KHz). Press this button over 2 seconds, the
system searches the radio stations of smaller frequencies
automatically; the digital phase locked loop will lock the FM
station automatically and the liquid crystal shows the
frequency of this station; When it reaches to the limit of
87.5MHz, press this button again and the frequency jumps to

Operation instruction manual of model:PR968x
- 10 -
108.0MHz.
9.4 When the FM radio is on,press“ ” till “VOL” on LCD blinks,
then press “ ” to increase the volume,press“ ”to decrease
the vollume.The adjust range is 0-20.
9.5 Station storage/select
9.5.1 Station storage:when select the station frequency to be
stored, press “ ” till“CH” on LCD blinks, then press “ ”
or “ ” to choose the position to be stored (1-18,18
positions in total),then press“ ” the frequency shall be
stored in the selected location,LCD shows the present
frequency.
9.5.2 Station select:when FM function is on,press “ ”
till“CH” on LCD blinks, then press “ ” or “ ” to select the
stored frequency(1-18,18 positions in total).
9.6 When press“ ”to choose different functions,if no operation
with“ ”、“ ”for 5 seconds, system will quit from the state, or
press“ ” again to quit from the state.
10 Play CD program.
10.1 When the system is on,press“ 、” till cursor select “Music”,
press“ ”till LCD displays “CD”, CD function is turned on;
then press“ ” again to turn off CD,“CD”will not show on LCD.
10.2 When the CD is on,press“ ” till “VOL” on LCD blinks, then
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Beliebte Controller Handbücher anderer Marken

ABB
ABB ACS580-01 drives Bedienungsanleitung

Panasonic
Panasonic GM1 Series Bedienungsanleitung

Emerson
Emerson SW93 Bedienungsanleitung

AutoAqua
AutoAqua Smart ATO micro SATO-120P Bedienungsanleitung

Panasonic
Panasonic FP? Positioning Unit RTEX Bedienungsanleitung

Alpha IP