Specim FX17 Bedienungsanleitung

Specim FX17 - Reference Manual 1.1

| Contents | 2
Contents
Specim FX17..............................................................................................................4
Legal Information................................................................................................................................................. 4
Description................................................................................................................. 6
Overview............................................................................................................................................................... 6
External Interfaces................................................................................................................................................ 7
Power Connector.......................................................................................................................................7
Camera Link Camera External Interfaces................................................................................................ 8
GigE Camera External Interfaces.............................................................................................................8
Frame Grabbers.....................................................................................................................................................9
Compatible Frame Grabbers.....................................................................................................................9
Frame Grabber Relevant Configuration................................................................................................... 9
Installation Guide................................................................................................... 11
Installation Setup Overview............................................................................................................................... 11
Camera Mounting............................................................................................................................................... 11
Cabling the Camera Link Camera......................................................................................................................13
Cabling the GigE Camera.................................................................................................................................. 14
Setting the Jumbo Frame Value......................................................................................................................... 15
Software Options.....................................................................................................18
Lumo Software....................................................................................................................................................18
SpecSensor SDK.................................................................................................................................................18
ASCII Commands...............................................................................................................................................18
GigE Vision.........................................................................................................................................................18
Functionality............................................................................................................ 19
Image Aqcuisition...............................................................................................................................................19
Readout Modes....................................................................................................................................... 19
Readout Timing.......................................................................................................................................21
Reduction of Image Size.................................................................................................................................... 23
Region of Interest (ROI)........................................................................................................................ 23
Multiple Regions of Interest...................................................................................................................24
Trigger and Strobe.............................................................................................................................................. 25
Image Correction................................................................................................................................................ 30
Digital Gain and Offset...................................................................................................................................... 32
Status Line.......................................................................................................................................................... 32
Test Images......................................................................................................................................................... 33
Configuration Options............................................................................................37
MROI Configuration in Lumo........................................................................................................................... 37
Changing AIE Settings....................................................................................................................................... 37
Triggering and Strobe through Power Connector.............................................................................................. 38
External Trigger Configuration.......................................................................................................................... 39

| Contents | 3
Maintenance Guide.................................................................................................40
Important Maintenance Information...................................................................................................................40
Cleaning the Fore Optics....................................................................................................................................40
Troubleshooting....................................................................................................... 41
Troubleshooting FX............................................................................................................................................ 41
Technical Information............................................................................................ 42
Optical Performance........................................................................................................................................... 42
Performance Characteristics............................................................................................................................... 42
Mechanical Specifications.................................................................................................................................. 43
Electrical Specifications......................................................................................................................................44
Environmental Specifications............................................................................................................................. 45

| Specim FX17 | 4
Specim FX17
Legal Information
Certification
Specim, Spectral Imaging Ltd has developed Quality Management System for its use covering design, development,
manufacturing, sales and support of optical measurement devices. QMS follows ISO9001:2015 and enables more
efficient operation and product management in a systematic way utilizing metrics. Specim QMS has been audited by
Bureau Veritas Certification Holding SAS – UK Branch and found to be in accordance with the requirements of the
management system standards.
Warranty Conditions
SPECIM warrants the Product, provided the serial number appears on the Product and it is as originally configured by
the factory, against defects in materials or due to faulty workmanship, as follows:
For a period of two years (24 months) from the date of delivery to the customer there will be no labor and material
charges for repairing or replacing (depending on the defect type) the defective Product. When the parts are sent
to SPECIM for repair the customer will cover the delivery costs and after the repair the parts are sent back to the
customer at SPECIM’s cost.
SPECIM's liability to user of the Product shall in no event exceed the actual cash amount received by SPECIM for the
defective Product. If failure of the Product has resulted from accident, abuse, or misapplication, SPECIM shall have
no responsibility under this limited warranty. SPECIM shall not be liable for any direct or indirect damages arising
out of the use of, or inability to use this product.
Limited Liability
1. SPECIM shall in no event be liable for loss of production, loss of business, loss of profits or loss of use, loss of
data or revenue, damage to property, or for any special, indirect, incidental or consequential damages.
2. The aggregate liability of SPECIM is limited to the sum of money, actually paid by the Customer to SPECIM for
the system delivered.
The Warranty and Limited Liability clauses above in this quote shall supersede other possible contract clauses
between SPECIM and the customer regarding SPECIM's warranty responsibility and liability.
Disclaimer
All information provided in this guide and provided manuals is believed to be complete, accurate and reliable at the
time of delivery. No responsibility is assumed by Specim, Spectral Imaging Oy Ltd. for its use. Specim, Spectral
Imaging Oy Ltd reserves the right to make changes to this information without notice. Reproduction of this manual
in whole or in part, by any means, is prohibited without prior permission having been obtained from Specim, Spectral
Imaging Oy Ltd.
Specim IQ ® and Specim IQ Studio ® are registered EU trademarks (Nos. 016777393 and 016777419) owned by
SPECIM, Spectral Imaging Ltd.
Contacting support
Further information and technical support are available from Specim, Spectral Imaging Oy Ltd. in Finland. Contact
information:
All rights reserved - Specim, Spectral Imaging Oy Ltd.

| Specim FX17 | 5
•WWW: www.specim.fi
•Email: [email protected]
• Tel: +358 (0)10 4244 400
All rights reserved - Specim, Spectral Imaging Oy Ltd.

| Description | 6
Description
Overview
FX17 camera is built around the monochrome InGaAs image sensor. It is designed for standard applications in
industrial and laboratory use. FX17 works in a push-broom mode, and collects hyperspectral data in the NIR (950 to
1700 nm) region through single fore optics.
There are two versions of the FX17 camera:
• FX17 with Camera Link interface
• FX17e with GigE interface
These specifications apply to all FX17 camera versions.
Figure 1: FX17 Spectral Camera
Camera data path
A diagram of the camera data path is shown in the figure below.
Figure 2: Camera data path
Feature Overview
Feature Characteristics
Image sensor CMOS
Operating range 950 to 1700 nm
Image correction • Offset and hot pixel correction
All rights reserved - Specim, Spectral Imaging Oy Ltd.

| Description | 7
Feature Characteristics
• Automatic Image Enhancement (AIE)
Image size reduction Multiple Regions of Interest (MROI)
Trigger modes Opto isolated trigger input and opto isolated strobe
output
Image correction
The camera includes the following image corrections:
• Offset and hot pixel correction
• Automatic Image Enhancement (AIE) means that spectral calibration will be the same for every FX camera, and
that smile and keystone will be corrected to practically zero for all cameras.
A customer with several cameras can replace one camera with another and still have the same spectral calibration
and smile/keystone without additional calibration.
All the corrections are enabled by default.
Image size reduction
The image sensor in FX series cameras is larger than the actual image size. Therefore the image area on the sensor
is defined using the Region of Interest (ROI) feature, and the ROI values are provided in the calibration pack. ROI
feature is reserved for this purpose alone, and the values must not be changed.
You can use Multiple Regions of Interest (MROI) feature to define one or several regions of interest. Using MROI
feature requires 1 x 1 binning.
If you use AIE together with MROI, there must be additional 3 rows in the beginning and in the end of each MROI to
prevent corruption. These extra rows must then be discarded in data processing as their data may be invalid.
See the technical notes Setting MROI's in FX10/10e and FX17/17e and Maximum frame rates in FX10/10e and
FX17/17e for more information.
External Interfaces
Power Connector
There is one Fischer Connector DBPLU1031Z012|130G in the camera back panel.
Power Connector Pin numbering
All rights reserved - Specim, Spectral Imaging Oy Ltd.

| Description | 8
Table 1: Power Connector Pin-out
pin # I/O Type Name Description
1 O ISO_OUT0 General purpose Output 0, single-ended output
2 O ISO_STROBE Default Strobe out, single-ended output
3 O RESERVED Reserved, do not connect
4 PWR CAMERA_GND Camera GND, 0V
5 PWR CAMERA_PWR Camera Power 12V (+/- 10%)
6 PWR ISO_GND I/O GND, 0V
7 I ISO_IN0 General purpose input 0
8 I ISO_TRIGGER Default Trigger in (5-15 V)
9 O RESERVED Reserved, do not connect
10 O RESERVED Reserved, do not connect
11 O RESERVED Reserved, do not connect
12 O RESERVED Reserved, do not connect
Camera Link Camera External Interfaces
Camera Link Connector
There is a standard MDR 26-pin camera link connector on the back panel of the camera for camera control signals
and serial communication.
For more information on Camera Link connector, refer to Camera Link interface standard specifications.
LED Indications
There is one green LED in the FX camera back panel.
LED Status
Not lit Power off
Blinking green in startup Starting up
Stable green Power on, not recording
Blinking green Recording, data being transferred
Note: Camera blinks briefly during startup. This period can be very short and therefore easy to miss.
GigE Camera External Interfaces
GigE Connector
There is a standard GigE M12 X-coded Ethernet connector on the back panel of the camera for camera control signals
and serial communication.
All rights reserved - Specim, Spectral Imaging Oy Ltd.

| Description | 9
LED Indications
There are three green LEDs in the FX camera back panel, one for status and two for GigE traffic indication.
Status LED Status
Not lit Power off
Stable green Power on
GigE LED 1 Status
Not lit No data connection
Blinking green Data connection active
GigE LED 2 Status
Not lit No data traffic
Blinking green Data being transmitted
Frame Grabbers
Compatible Frame Grabbers
When you use a Camera Link camera, the system requires a frame grabber installed on the data aqcuisition PC.
The frame grabbers that have been tested to work with LUMO in WIN10 are:
• NI 1430
• Dalsa Xtium-CL_MX4
• Epix PICXi EB1
Frame Grabber Relevant Configuration
The parameters and settings, which are essential to configure the frame grabber are shown in the following table.
Table 2: Summary of parameters needed for frame grabber configuration
Pixel Clock per Tap 80 MHz
Number of Taps 2
Greyscale resolution 12 bit / 10 bit / 8 bit
Line pause 18 clock cycles
All rights reserved - Specim, Spectral Imaging Oy Ltd.

| Description | 10
CC1 18 clock cycles
CC2 not used
CC3 not used
CC4 not used
Camera Link port and bit assignments are compliant with the Camera Link standard
Table 3: Camera Link 2 Tap port and bit assignments
Bit Tap 0 Tap 1 Tap 0 Tap 1 Tap 0 Tap 2
8 Bit 8 Bit 10 Bit 10 Bit 12 Bit 12 Bit
0 (LSB) A0 B0 A0 C0 A0 C0
1 A1 B1 A1 C1 A1 C1
2 A2 B2 A2 C2 A2 C2
3 A3 B3 A3 C3 A3 C3
4 A4 B4 A4 C4 A4 C4
5 A5 B5 A5 C5 A5 C5
6 A6 B6 A6 C6 A6 C6
7 (MSB of 8
Bit)
A7 B7 A7 C7 A7 C7
8 - - B0 B4 B0 B4
9 (MSB of 10
Bit)
- - B1 B5 B1 B5
10 - - - - B2 B6
11 (MSB of 12
Bit)
- - - - B3 B7
All rights reserved - Specim, Spectral Imaging Oy Ltd.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Specim Digitalkamera Handbücher