Electrical Supply
Installation must be carried out by a qualified electrician in
accordance with BS 7671:2008 Wiring Regulations.
230/240V AC 50/60Hz mains supply to a suitable SELV
LED Driver.
Site conditions: LED equipment is more susceptible to
static damage and over voltage than previous technology.
Before handling or connecting to the mains supply ensure
that all Stoane Lighting (SL) products are protected from
static discharge and that the mains supply is to regulation.
(230V +10 -6%)
Mains cables must be double insulated, strain relieved
and separated from E.L.V output cables.
This unit requires a constant current driver. 500mA Max.
Observe polarity:
Positive (+) is marked as RED.
Incorrect supply or reverse polarity can cause irreparable
damage.
All connections must be made before switching on mains.
If the supply is energised prior to making the connections
to the fitting then the resulting surge will damage the LED.
Multiple LEDs should be wired in series, refer to driver
instructions for minimum/maximum load.
The entire dimming control circuit source must be of SELV
insulation class.
Maintenance:
All lighting equipment is delicate and easily damaged
through misuse or inappropriate installation (mechanical
or electrical). Repairs and replacements may cause
delays and will be chargeable. Contact SL for support if
required.
All Stoane Lighting products are covered by a five year
Warranty and a 25 year Duty of Care. Products are
designed to be upgraded, adapted and refreshed using
our comprehensive ReNew service. For more information
on our ReNew service and for full Warranty terms and
conditions visit stoanelighting.com or contact us at the
address shown.
The IP rating stated is applicable only when the fitting has
been installed as per these instructions.
The light source contained in this luminaire shall only be
replaced by the manufacturer or his service agent or a
similar qualified person.
Installation
Check that the mounting surface is suitable for the
installation of this fitting.
A 33mm diameter cutout is required.
Step 1 Make mains connections to SELV LED driver
and extra low voltage connections to the
fitting.
Step 2 Retaining Wings: Hold in the springs and
push into the cutout. Once released the
springs will hold the fitting in place.
OR
Retaining Ring: Insert fitting into cutout and
secure by screwing the retaining ring onto the
rear of the fitting.
Ensure supply driver and connectors are housed
indoors OR in a suitably IP rated enclosure. Cable
ends must be suitably waterproofed. Inspect supply
cables before installation to ensure there is no
damage which will allow water to enter the fitting.
After opening the sealed portion of the luminaire for
any reason, SL recommends running the fitting for 15
minutes with the lid open to expel moisture before
closing it up. This will prevent condensation on the
lens and protect the fitting from corrosion.
Ensure that the installation of this fitting does not
compromise any fire barrier offered by your ceiling.
Intumescent downlighter fire hoods should be used to
maintain the integrity of the barrier in the event of a
fire.
Do not cover the luminaire with insulation. Heat sinks
and fan assisted lamps must be kept free from dust
and well ventilated to ensure long term reliability and
light quality.
WARNING: Do not look at exposed LED lamps in
operation. Eye injury can result.
Cleaning:
Fully isolate the fitting and allow to cool.
Clean the fitting with a slightly damp lint free cloth
from a mild solution of soap and water. The fitting
must be completely dry before reconnecting power.
Incompatible or abrasive chemicals can damage the
fitting, contact SL for advice if required.