Strand Lighting R21 Bedienungsanleitung


Strand Lighting Offices
The material in this manual is for information purposes only and is subject to change without notice. Strand
Lighting assumes no responsibility for any errors or omissions which may appear in this manual. For comments and
suggestions regarding corrections and/or updates to this manual, please contact your nearest Strand Lighting office.
El contenido de este manual es solamente para información y está sujeto a cambios sin previo aviso. Strand
Lighting no asume responsabilidad por errores o omisiones que puedan aparecer. Cualquier comentario, sugerencia
o corrección con respecto a este manual, favor de dirijirlo a la oficina de Strand Lighting más cercana.
Der Inhalt dieses Handbuches ist nur für Informationszwecke gedacht, Aenderungen sind vorbehalten. Strand
Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer, die in diesem Handbuch auftreten. Für
Bemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und/oder
Aktualisierungen in diesem Handbuch, moechten wir Sie bitten, Kontakt mit der naechsten Strand Lighting-
Niederlassung aufzunehmen.
Le matériel décrit dans ce manuel est pour information seulement et est sujet à changements sans préavis. La
compagnie Strand Lighting n'assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel.
Pour tous commentaires ou suggestions concernant des corrections et/ou les mises à jour de ce manuel, veuillez s'll
vous plait contacter le bureau de Strand Lighting le plus proche.
Information contained in this document may not be duplicated in full or in part by any person without prior written
approval of Strand Lighting. Its sole purpose is to provide the user with conceptual information on the equipment
mentioned. The use of this document for all other purposes is specifically prohibited.
Document Number: 2-450186-010
Version as of: 22 June 2011
R21 Powered Raceway Installation Guide
©2011 Philips Group. All rights reserved.
Strand Lighting - Dallas
10911 Petal Street
Dallas, TX 75238
Tel: 214-647-7880
Fax: 214-647-8031
Strand Lighting - New York
267 5th Ave, 4th Floor
New York, NY 10016
Tel: 212-213-8219
Fax: 212-532-2593
Strand Lighting - Asia Limited
Room 6-10, 20/F Delta House 3 On Yiu Street
Shatin, N.T. Hong Kong
Tel: + 852 2757 3033
Fax: + 852 2757 1767
Strand Selecon - Auckland
19-21 Kawana Street
Northcote, Auckland 0627
New Zealand
Tel: +64 9 481 0100
Fax: +64 9 481 0101
Strand Lighting - Europe
Marssteden 152
Enschede 7547 TD
The Netherlands
Tel: +31 53 4500424
Fax: +31 53 4500425
Website:
www.strandlighting.com

1
R21 Powered Raceway Installation Guide
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
b. Do not use outdoors.
c. Do not mount near gas or electric heaters.
d. Equipment should be mounted in locations and at heights where it will not readily be subjected to
tampering by unauthorized personnel.
e. The use of accessory equipment not recommended by the manufacturer may cause an unsafe
condition.
f. Do not use this equipment for other than intended use.
g. Refer service to qualified personnel.
SAVE THESE INSTRUCTIONS.
WARNING: You must have access to a main circuit breaker or other power disconnect device
before installing any wiring. Be sure that power is disconnected by removing fuses or turning the
main circuit breaker off before installation. Installing the device with power on may expose you to
dangerous voltage and damage the device. A qualified electrician must perform this installation.
WARNING: Refer to National Electrical Code® and local codes for cable specifications. Failure to
use proper cable can result in damage to equipment or danger to persons.
WARNING: This equipment is intended for installation in accordance with the National Electric
Code® and local regulations. It is also intended for permanent installation in indoor applications
only. Before any electrical work is performed, disconnect power at the circuit breaker or remove the
fuse to avoid shock or damage to the control. It is recommended that a qualified electrician perform
this installation.
CAUTION: Wire openings MUST have fittings or lining to protect wires/cables from damage. Use
90° C copper wire only! Aluminum wire may not be used.

Installation Guide R21 Powered Raceway
2Table of Contents
TABLE OF CONTENTS
Strand Lighting Offices........................................................................................................Inside Front Cover
Important Safeguards
Table of Contents
Preface
About This Guide ................................................................................................................................................... 3
Additional Resources.............................................................................................................................................. 3
Other Manuals................................................................................................................................................. 3
Additional Resources for DMX512................................................................................................................. 3
Overview
Installation and Checkout Sequence....................................................................................................................... 4
Components
R21 Powered Raceway........................................................................................................................................... 5
Raceway Control Modules ..................................................................................................................................... 6
Dimmer Modules.................................................................................................................................................... 7
Mechanical Considerations
Tools and Supplies.................................................................................................................................................. 8
Installation Location............................................................................................................................................... 8
Wire Routing........................................................................................................................................................... 9
Wiring Requirements.............................................................................................................................................. 9
Installation Procedure
Connecting Sections ............................................................................................................................................. 10
Mounting the Unit ................................................................................................................................................ 10
Single-Pipe Methods ..................................................................................................................................... 10
Double-Pipe Methods.................................................................................................................................... 11
Threaded Rod and Wall Mount Methods...................................................................................................... 11
Connecting Power Wiring .................................................................................................................................... 12
Overview ....................................................................................................................................................... 12
Line Power..................................................................................................................................................... 13
Connecting Control Wiring .................................................................................................................................. 14
Overview ....................................................................................................................................................... 14
DMX512........................................................................................................................................................ 15
Vision.net Networks (SVN/485)................................................................................................................... 16
Termination of Shielded Cable...................................................................................................................... 16
Termination of Ethernet Cable...................................................................................................................... 17
Master/Slave Wiring (DIM96)...................................................................................................................... 18
Panic Input..................................................................................................................................................... 18
Installing Cable Tray (if applicable)..................................................................................................................... 19
Complete and Test ................................................................................................................................................ 19
Maintenance Procedures
Replacing a Dimmer Module................................................................................................................................ 20
Appendix A.
R21 Powered Raceway Dimmer DIP Switch Settings......................................................................................... 21

3
R21 Powered Raceway Installation Guide

Installation Guide R21 Powered Raceway
4Preface
PREFACE
1. About This Guide
The document provides installation instructions for all configurations of the R21 Powered Raceway.
Please read all instructions before installing or using this product. Retain this guide for future reference.
2. Additional Resources
Other Manuals
For additional operation, maintenance, and setup information, please see the following Strand manuals:
• R21 Powered Raceway Operation and Maintenance Guide
• Dimmer.net Software Manual
Dimmer.net software and manuals may be downloaded at www.strandlighting.com.
Additional Resources for DMX512
For more information on installing DMX512 control systems, the following publication is available for purchase
from the United States Institute for Theatre Technology (USITT), "Recommended Practice for DMX512: A Guide for
Users and Installers, 2nd edition" (ISBN: 9780955703522). USITT Contact Information:
USITT
315 South Crouse Avenue, Suite 200
Syracuse, NY 13210-1844 USA
1-800-938-7488 or 1-315-463-6463
www.usitt.org

Installation and Checkout Sequence 5
R21 Powered Raceway Installation Guide
OVERVIEW
1. Installation and Checkout Sequence
The R21 Powered Raceway is shipped from the factory in a ready-to-install configuration. The following steps will
be required to successfully install the unit(s) at your location:
1) Unpack and Inspect
Remove all components from shipping container(s) and inspect for damage. Compare the equipment you
received to the packing list. If these do not match, contact Strand Lighting Customer Service at: 1-800-
4STRAND (U.S.) or 1-214-647-7880 (international).
2) Review ALL Instructions
Read this entire installation guide before you start the installation.
3) Gather Tools
Obtain all tools and supplies listed in "Tools and Supplies" on page 9.
4) Choose Appropriate Installation Location
Ensure installation location meets the requirements listed in "Installation Location" on page 9.
5) Plan Wire Routing
Decide where line and control wiring will enter the unit.
6) Install Unit
Following the instructions provided in "Installation Procedure" on page 11, mount and wire the unit.
7) Checkout
Perform the steps listed in "Complete and Test" on page 20 to ensure that the unit has been properly installed.
8) Call For Approval
Do not energize the R21 Powered Raceway until the wiring has been approved by an authorized technician. Call
Strand Lighting to schedule an Engineering Checkout.

Installation Guide R21 Powered Raceway
6Components
COMPONENTS
1. R21 Powered Raceway
The R21 Powered Raceway - up to 96 feet long - contains one Raceway Control Module (RCM), up to forty-eight
20A Dual Dimmer Modules, and at least one Power Terminal Box (PTB). The number of Power Terminal Boxes is
determined by the location and the number of necessary power feeds.
Figure 1: R21 Powered Raceway Component Overview
Raceway Control Module (RCM)
Located on Raceway or Rack Mount
Power Feed Multi-conductor Cable
with Strain Relief (optional)
Hanger Bracket
- six types available
Pigtail Receptacle - Standard Length 18"
(choice of stagepin, twistlock, or Edison
connectors)
Dual Dimmer Module
(2400 Watt total)
Focus Button /
LED Indicator
Flush Receptacle (choice of stage pin,
twistlock, or Edison connectors)
1-1/2" Schedule 40 Pipe
(provided by others)
Control Cable
Tray (optional)
Power Terminal Box (PTB)
DMX512 In/Thru Connectors,
RJ45 Ethernet Connector &
Serial Connector (diagnostic)
SIDE VIEW
FRONT VIEW
Power Terminal Box Interior View (Typical)
Ground Terminal
Input
Output Power Wiring
(pre-wired at factory)
Input Power Terminals
Power
Feed
EXAMPLE CONFIGURATION
Raceway Components May Vary
A
C
A
BSee next pages
for detail illustrations
B
C
Note: All components are pre-wired
at the factory except terminal box
line input connections.

Raceway Control Modules 7
R21 Powered Raceway Installation Guide
2. Raceway Control Modules
The Raceway Control Module (RCM) is used to configure the R21 Powered Raceway. The RCM comes in two
configurations, a 19-inch "rack mount" configuration for remote applications or a "head end" configuration for local
applications.
Figure 2: Head End RCM Component Detail
Figure 3: Rack Mount RCM Components
A
SIDE VIEWFRONT VIEW
Menu
Status
Menu Navigation
Escape
Button
Display
LEDs
and Enter Buttons
Serial Port
Ethernet
DMX512 In
Port
B
DMX512-Over-Ethernet Output
(Ethernet Enabled Units)
DMX512 Thru
(DMX Only Units)
- or -
FRONT VIEW
REAR VIEW
Menu
Status
Menu Navigation
Escape
Button
Display
LEDs
and Enter Buttons
Ethernet
Vision.net Port
A/C Input
DMX512
Termination
Port
DMX512
Ground
DMX512-Over-Ethernet
Output (Ethernet-Enabled Units)
DMX512 In & Thru
(DMX Only Units)
Data Ports
Panic
Input
Data Port
Enable Switches

Installation Guide R21 Powered Raceway
8Components
3. Dimmer Modules
R21 Powered Raceway Dimmer Modules contain one 20A dual dimmer with 20A (2400W) power shared between
the two dimmers. Each dual dimmer module includes two Focus/LED Indicator buttons, which function as both focus
adjustment controls and status indicators.
Figure 4: Dimmer Module Detail
C
Focus Button /
LED Indicator
Inhaltsverzeichnis
Andere Strand Lighting DJ-Equipment Handbücher
Beliebte DJ-Equipment Handbücher anderer Marken

thomann
thomann Stairville DJ Lase 40-G MK-III Bedienungsanleitung

Eagletone
Eagletone 6 Eyes Flower Bedienungsanleitung

EuroLite
EuroLite FLD-1508 Bedienungsanleitung

Technical Pro
Technical Pro LG8xSEA Bedienungsanleitung

JB Systems
JB Systems Lounge Laser DMX Bedienungsanleitung

Lightmaxx
Lightmaxx Vega Halo 90 Bedienungsanleitung

Elation
Elation FUZE WASH Z350 Bedienungsanleitung

Maverick
Maverick MK3 WASH Bedienungsanleitung

Infinity
Infinity TF-260C7 Fresnel Bedienungsanleitung

Chauvet
Chauvet EVE E-50Z Bedienungsanleitung

Eliminator Lighting
Eliminator Lighting E 138 Bedienungsanleitung

EuroLite
EuroLite Mini Multicolor LED Flashing Light SC Bedienungsanleitung