Wine Storage Installation Guide

WINE STORAGE
Contents
3Wine Storage
4Opening Dimensions
5Electrical
6Preparation
6Anti-Tip Bracket
8Placement
8Alignment
10 Custom Panels
12 Panel Installation
14 Completion
Features and specications are subject to change at any
time without notice. Visit subzero.com/specs for the most
up-to-date information.
Important Note
To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.

subzero.com
|
3
Product Information
Important product information including the model and
serial number are listed on the product rating plate. The
rating plate is located on the handle side wall, directly below
the control panel. Refer to the illustration below.
If service is necessary, contact Sub-Zero factory certied
service with the model and serial number. For the name
of the nearest Sub-Zero factory certied service or for
questions regarding the installation, visit the contact & sup-
port section of our website, subzero.com or call Sub-Zero
customer care at 800-222-7820.
WINE STORAGE
Tools and Materials
•Screwdrivers—standard, Phillips and Torx.
•Power drill.
•Drill bits (masonry bits required for concrete installation).
•Standard socket and wrench set.
•2' and 4' levels.
•Material to protect home, ooring and cabinetry during
installation.
Rating plate location.
RATING PLATE

4
|
Sub-Zero Customer Care 800.222.7820
SITE PREPARATION
Opening Dimensions
WINE STORAGE OPENING DIMENSIONS
COLUMN W H
IW-18 18" (457) 84" (2134)
IW-24 24" (610) 84" (2134)
IW-30 30" (762) 84" (2134)
TALL W H
IW-30R 30" (762) 84" (2134)
The depth of each wine storage model is 24" (610). Allow for
panel thickness when planning the nished opening depth.
A minimum 31/2"(89) nished return is required on all sides
of the opening. Framed cabinets will require additional
nished ller material behind the face frame for a proper
installation. Refer to the illustration.
DUAL INSTALLATION
When installing two units side by side in a dual installa-
tion, the opening width is the width of the two units added
together. A dual installation kit will be required for this instal-
lation. If a dual installation kit is not specied, a minimum
2" (51) ller strip is required between units.
Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the nd a
showroom section of our website, subzero.com. For ques-
tions regarding the installation, call Sub-Zero customer care
at 800-222-7820.
25" (635)
OPENING
DEPTH
W
OPENING WIDTH
H
OPENING
HEIGHT
NOTE:
31/2"(89) finished returns will be visible and should be finished to match cabinetry.
SIDE
VIEW
TOP VIEW
FRONT VIEW
31/2"(89)
FINISHED
RETURN
FRAMELESS CABINETRY
3/4"
(19)
TYPICAL 31/2"(89)
FINISHED
RETURN
FILLER
FRAMED CABINETRY
W W

subzero.com
|
5
SITE PREPARATION
HOME SECURITY CONNECTION
If the unit will be connected to a home security system, low-
voltage leads must be provided to the unit. Two connectors
are located behind the top trim. Provide 10' (3 m) minimum
lead wires for each connector, exiting the back wall near the
electrical receptacle.
Remove the top trim by disengaging the trim from the hinge
side of the unit. Rotate the trim and remove the trim pin from
the handle side vertical support. Refer to the illustrations
below. Use spade terminals or wire nuts to make proper
wiring connections. Refer to the following color codes:
•Normally open contacts—white with red stripe wire.
•Common—gray with white stripe wire.
CAUTION
The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be used
to switch line power. Any unused terminals should be
completely insulated and all wires should be secured
away from conductive or moving components.
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
CAUTION
The outlet must be checked by a qualied electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
ELECTRICAL SUPPLY LOCATION
WIDTH A
18" Model 6" (152)
24" Model 91/2"(241)
30" Model 121/2"(318)
A
1/4" (6)
1/4" (6)
41/4"
(108)
41/2"
(114)
FLOOR
LEFT SIDE
OF OPENING
Electrical supply location.
PIN
Top trim—hinge side.
Top trim—handle side.

6
|
Sub-Zero Customer Care 800.222.7820
SITE PREPARATION
Preparation
Uncrate the unit and inspect for damage. Remove the wood
base and discard shipping bolts and brackets. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket and hardware.
Remove the kickplate by extracting the two mounting
screws. Refer to the illustration below.
SCREW
Kickplate removal.
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
The back of the anti-tip bracket must be installed 24" (610)
from the front of the unit (without panels).
Use all anti-tip bracket hardware as instructed for wood or
concrete oors.
IMPORTANT NOTE: For wood or concrete oor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE: In some installations the subooring or
nished oor may necessitate angling the screws used to
fasten the anti-tip bracket to the back wall.
ANTI-TIP HARDWARE
1 Anti-tip bracket
6 #12 x 21/2" pan head screws
23/8"–16 x 33/4" wedge anchors
6 #12 at washers

subzero.com
|
7
SITE PREPARATION
CONCRETE WEDGE ANCHOR INSTALLATION:
1Drill a 3/8"(10) diameter hole any depth exceeding the
minimum embedment. Clean the hole or drill additional
depth to accommodate drill nes.
2Assemble the washer and nut ush with the end of
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is ush with the
surface material.
3Expand the anchor by tightening the nut 3–5 turns past
hand-tight position or to 25 foot-pounds of torque.
WARNING
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
CAUTION
Always wear safety glasses and use other neces-
sary protective devices or apparel when installing or
working with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use in
new concrete which has not had sufcient time to cure.
The use of core drills is not recommended to drill holes
for the anchors.
Anti-Tip Bracket
WOOD FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening,
drill pilot holes 3/16"(5) diameter maximum in the wall studs
or wall plate. Use the #12 screws and washers to secure the
brackets. Verify the screws penetrate through the ooring
material and into wall studs or wall plate a minimum of 3/4"
(19). Refer to the illustration and chart below.
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening,
drill pilot holes 3/16"(5) diameter maximum in the wall studs
or wall plate. Drill 3/8"(10) diameter holes into the concrete
a minimum of 11/2"(38) deep. Use the #12 screws and
washers to secure the brackets to the wall, and use the 3/8"
wedge anchors to secure the brackets to the oor. Verify the
screws penetrate wall studs or wall plate a minimum of 3/4"
(19). Refer to the illustration and chart below.
ANTI-TIP BRACKET PLACEMENT
WIDTH A
18" Model 9" (229)
24" Model 12" (305)
30" Model 15" (381)
A
A
SUBFLOORING
WOOD FLOOR
WALL PLATE
FINISHED
FLOORING
A
A
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
11/2"(38)
min
Wood oor.
Concrete oor.

8
|
Sub-Zero Customer Care 800.222.7820
INSTALLATION
Placement
CAUTION
Before moving the unit into position, secure the door/
drawers closed and protect any nished ooring.
Use an appliance dolly to move the unit near the opening.
The front leveling legs are extended below the front rollers to
improve stability during placement. Once the unit is placed
in front of the opening, completely retract the front leveling
legs to allow the unit to be rolled into position. Front and
rear leveling legs can be adjusted from the front once the
unit is positioned.
If the unit has been on its back or side, it must stand upright
for a minimum of 24 hours before connecting power.
Plug the power cord into the grounded outlet and roll the
unit into position. Verify the anti-tip bracket is properly
engaged.
Alignment
LEVELING
Once the unit is in position, height adjustment can be made
from the front. Using a Phillips drive, turn clockwise to raise
the unit or counterclockwise to lower. Use the lowest torque
setting when using a power drill. Do not turn the leveling
legs by hand. Refer to the illustration below.
When the unit is properly leveled, door/drawer adjustments
are less likely to be necessary.
IMPORTANT NOTE: Level the unit to the oor, not sur-
rounding cabinetry. This could affect the operation of the
unit, such as door closing.
WARNING
To reduce the possibility of the unit tipping forward,
the front leveling legs must be in contact with the oor.
REAR
ADJUSTMENT
FRONT
ADJUSTMENT
Leveling.

subzero.com
|
9
INSTALLATION
Alignment
DEPTH ADJUSTMENT
Adjust the depth of the unit to t ush with surrounding
cabinetry. Follow these steps for a precision t:
1Place decorative panel on a protected work surface.
Place the panel thickness gauge next to the panel to
determine which notch corresponds with the panel thick-
ness. Refer to the illustration below. Once the proper
notch has been determined, mark that notch with a
marker.
2With the door closed, position the top of the unit using
the panel thickness gauge. Refer to the illustration
below. Insert a #8 x 1/2" stainless steel screw above the
hinge, then insert a #8 x 1/2" pan head screw on the
handle side of the unit. For narrower units, the door may
need to be opened to access the handle side screw
location. Repeat the process to align the bottom.
PANEL THICKNESS
GAUGE
FRONT OF
UNIT
CABINETRY
FACE
FRAME
SCREW
SIDE TRIM
Panel thickness.
Unit depth.
ANCHORING
Once the top and bottom are aligned, verify the door/
drawers open properly, then install remaining screws in each
side trim.

10
|
Sub-Zero Customer Care 800.222.7820
Custom Panels
Custom door/drawer panels and handle hardware must
be installed. Stainless steel panels are available through an
authorized Sub-Zero dealer. For local dealer information,
visit the nd a showroom section of our website,
subzero.com.
The thickness of the custom panel can vary. A minimum
5/8"(16) thick panel is required, but the thickness can be
increased provided it does not exceed the maximum panel
weight indicated in the chart below. The depth of each
model is 24" (610). Allow for panel thickness when planning
the nished opening depth.
PANEL REQUIREMENTS
WEIGHT PER PANEL MAX
Door 35 lb (16 kg)
Door (IW-30R) 25 lb (11 kg)
Drawer 15 lb (7 kg)
PANEL THICKNESS MIN
All Panels 5/8"(16)
Reveals between panels can vary, 1/8"(3) reveals are typical.
CAUTION
When installing a panel thicker than 1" (25), the 90° stop
may be required to prevent damage to the unit and
adjacent cabinetry.
CAUTION
As reveals between cabinetry and the unit decrease,
severe nger pinching can occur while door is closing.
Finish all sides of custom panels. They will be visible when
the door is open.
D-style handles are recommended. Stainless steel tubular
and pro handles are available through an authorized
Sub-Zero dealer. For local dealer information, visit the nd
a showroom section of our website, subzero.com. Door
handles must be located near the edge of the panel oppo-
site the hinge and should be centered top to bottom. Drawer
handles must be located near the top edge of each panel.
PANEL INSTALLATION