Sunsystem SPLIT R32-0126-1PH Bedienungsanleitung

EVI DC inverter heat pump
for heating and cooling -
split system
(with Wi-Fi control)
TECHNICAL PASPORT.
INSTALLATION AND OPERATION MANUAL
Version 0.2

2
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
GENERAL FEATURES:
1. General Features
1. Low running costs and high efficiency
·A high coefficient of performance (COP) of up
to 5 results in lower running costs compared
with traditional ASHP technology.
·No immersion heater supplement is required.
2. Reduced Capital Costs
·Simple installation
3. High Comfort Levels
·High storage temp. results in increased hot
water availability.
4. No potential danger of any inflammable,
gas poisoning, explosion, fire, electrical shock
which are associated with other heating
systems.
5. A digital controller is incorporated to
maintain the desired water temperature.
6. Long-life and corrosion resistant composite
cabinet stands up to severe climates.
7. Panasonic compressor ensures outstanding
performance, ultra energy efficiency, durability
and quiet operation.
8. Self-diagnostic control panel monitors and
troubleshoots heat pump operations to ensure
safe and reliable operation.
9. Intelligent digital controller with friendly
user interface and blue LED back light.
10. Separate isolated electrical compartment
prevents internal corrosion and extends heat
pump life.
11. The heat pump can operate down to
ambient air temperature of -30°C.
Dear clients, before using the device,
familiarize yourself with this instruction
for installation, storage and operation.
We hope that the appliance you have
purchased will contribute to creating coziness
in your home and reducing energy costs. The
purpose of this technical description and
operating instructions is to familiarize you with
the product and the conditions for its correct
installation and operation. Compliance with
the instructions in this instruction is in the
interest of the buyer and is one of the warranty
conditions.
EVI DC Inverter Air Source Heat
Pump is specially designed for domestic hot
water, home heating and cooling.
EVI DC Inverter Air Source heat
pumps transfer heat from the ambient air to
water, providing high-temperature hot water
up to 60°C. The unique high-temperature heat
pump is widely used for house warming. With
innovative & advanced technology, the heat
pump can operate very well at -30°C ambient
temperature with high output temperatures
up to 60°C, which ensures the compatibility
with normal sized radiator based systems
without supplementation. Compared with
traditional oil/LPG boilers, EVI DC Inverter
heat pump produces up to 50% less CO2 whilst
saves 80% running cost.
Our heat pumps are not only highly efficient,
but also easy and safe to operate.

3
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
1. BASIC INSTRUCTIONS
AND WARNINGS
iBefore starting the installation
process, read the entire instruction.
iThe installation of the device must
strictly follow the instructions,
otherwise the warranty is void.
Any modification or replacement
of the original parts with others
automatically voids the warranty
given by the manufacturer. Use of
the device in environments and
conditions other than those described
in this manual automatically voids
any claims made.
Improper execution of electrical
bonding that does not conform to
good practice may result in injury.
Electrical wiring must be performed
by a qualified electrician.
The device must not be placed in an
aggressive environment that could
damage it (dusty rooms, explosive
substances in the air, open air, etc.).
In order to be sure of the correct
operation of the relief valve, periodic
annual checks of its operation should
be made. If necessary clean it of
limescale and make sure it is not
blocked.
A 0.8 MPa (8 bar) safety valve must
be connected to the inlet of the water
container, which guarantees that the
pressure will not exceed the nominal
one. It is forbidden to place a shut-off
valve between the water container
and the safety valve.
The boiler is intended for drinking
water storage, so it must necessarily
comply with the valid national
regulations for drinking water, or in
case of damage the validity of the
warranty will be void.
The device should never be operated
without water in the water tank.
The power cable has a standard
tip, which must be connected to a
standard outlet (16A; 230V). The
outlet must have a separate power
supply from the mains and there must
be no other connected consumers on
this circuit.
The device can be used by 1 person
familiar with the product‘s operating
instructions. Children over 8 years
old and people with disabilities
can use the device only under the
supervision of an instructed person.
During operation, it is forbidden to
move, lift, clean or repair the device.
The installation of the device must be
carried out according to the current
standards by an authorized specialist.
The device must not be blocked
or objects placed on it. If the
temperature exceeds 850C during
operation, contact a service center
immediately.
Make sure the device does not pose
a threat to anyone. Access to children
and uninstructed persons should be
restricted.
Do not place the unit in a room where
it cannot be removed.
Service and maintenance may only be
performed by an authorized service
technician. In case of damage, first
contact the technician who installed
the device.
Never clean the device with
preparations containing sand, soda,
acids, alcohols. Clean only with a
damp cotton cloth, making sure that
the appliance is disconnected from
the mains.
2. HEAT PUMP ENERGY SAVING TIPS
If you do not plan to use hot water for a

4
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
on the inlet and outlet water connecons for
ease of serviceability.
3.2. Installation details:
Prevailing local conditions, such as the
proximity and height of walls and proximity
to public access areas, must be taken into
account in any installation. The heat pump
must be positioned to provide clearance on all
sides for maintenance and inspection.
3.2.1. The place to install the heat pump must
have good ventilation and the air inlet/outlet
must not be obstructed.
3.2.2. The installation site must have good
drainage and be built on a solid foundation.
3.2.3. Do not install the unit in areas
accumulated with pollutants such as
aggressive gas (chlorine or acid), dust, sand
and leaves, etc.
3.2.4. For easier and better maintenance and
troubleshooting, there should be no objects
and walls closer than 1 m around the unit and
no obstructions within 2 meters, vertically, of
the air ventilation unit.
3.2.5. The heat pump must be mounted with
shock-resistant bushings to prevent vibration
and/or imbalance.
3.2.6. Although the controller is waterproof,
care should be taken to avoid direct sunlight
and high temperature. In addition, the heat
pump must be placed in such a way as to
ensure good visibility of the controller.
Note: We recommend installing shut-o valves
on the inlet and outlet water connecons for
ease of service.
3.3. Installation details:
Prevailing local conditions, such as the
proximity and height of walls and proximity
to public access areas, must be taken into
account in any installation. The heat pump
must be positioned to provide clearance on all
sides for maintenance and inspection.
3.3.1. The place to install the heat pump must
have good ventilation and the air inlet/outlet
must not be obstructed.
3.3.2. The installation site must have good
drainage and be built on a solid foundation.
prolonged period, then you might choose
to turn the heat pump off or decrease the
temp. setting of the control several degrees to
minimize energy consumption.
We offer the following recommendations to
help conserve energy and minimize the cost of
operating your heat pump without sacrificing
comfort.
2.1. A maximum water temp. of 60°C is
recommended.
2.2. It is recommended to turn off the heat
pump when ambient air temp. is less than
-30°C or if on vacation for longer than a week.
2.3. To save energy, it is recommended that
the heat pump is operated during daytime
when the ambient temperature is higher.
2.4. The heat pump must be installed outdoors.
To use the risk of freezing, always use a solution
of propylene glycol as a heat carrier.
3. HEAT PUMP INSTALLATION
3.1. The following items are needed and are to
be supplied by the installer for all heat pump
installaons:
3.1.1. Plumbing ngs.
3.1.2. Level surface for proper drainage.
3.1.3. Ensure that a suitable electrical supply
line is provided. See the rang plate on the
heat pump for electrical specicaons. Please
take a note of the specied current rang. No
juncon box is needed at the heat pump; Con-
necons are made inside of the heat pump
electrical compartment. Conduit may be at-
tached directly to the heat pump jacket.
3.1.4. It is advised to use PVC conduit for the
electrical supply line.
3.1.5. Use an addional water circulaon
pump in case of low ow.
3.1.6. It is necessary to install a magnec l-
ter at the inlet of the heat carrier in the heat
pump.
3.1.7. The plumbing should be insulated to re-
duce its heat loss.
Note: We recommend installing shut-o valves

5
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
3.3.3. Do not install the unit in areas
accumulated with pollutants such as
aggressive gas (chlorine or acid), dust, sand
and leaves, etc.
3.3.4. For easier and better maintenance and
troubleshooting, there should be no objects
and walls closer than 1 m around the unit and
no obstructions within 2 meters, vertically, of
the air ventilation unit.
3.3.5. The heat pump must be mounted with
shock-resistant bushings to prevent vibration
and/or imbalance.
3.3.6. Although the controller is waterproof,
care should be taken to avoid direct sunlight
and high temperature. In addition, the heat
pump must be placed in such a way as to
ensure good visibility of the controller.
3.3.7. Plumbing pipes must be installed
with adequate support to prevent
possible damage due to vibration.
The running water pressure must be
maintained above 196 kpa. Otherwise, a
booster pump must be installed.
3.3.8. The acceptable operating voltage range
should be within ±10% of the rated voltage.
The heat pump unit must be
grounded for safety purposes.
3.3.9. If the copper pipes length(between
outdoor unit and indoor unit) is within 5 meter
no need
extra refrigerant added,
(a) But if the copper pipe length is
above 5m, the added refrigerant volume will
be 60g/m for SUNSYSTEM SPLIT R32-0126-
1PH; 120g/m for SUNSYSTEM SPLIT R32-0220-
3PH. The max copper pipe length is 10meter
for SUNSYSTEM SPLIT R32-0126-1PH, 15meter
for SUNSYSTEM SPLIT R32-0220-3PH.
(b) The height difference between
outdoor unit and indoor unit is max 5meter for
SUNSYSTEM SPLIT R32-0126-1PH; Max 8meter
for SUNSYSTEM SPLIT R32-0220-3PH.

6
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
4. PREPARATION FOR INSTALLATION
4.1. Outdoor unit with 1 fan - components
B CA
G
H
K
F
E
D
L
N
O
R
M
P
S
COMPONENTS
АFan K High pressure safety relay
BAir inlet temperature sensor LHigh pressure side Schrader type valve
C. Heat exchanger (evaporator) MCompressor
DElectronic expansion valve NHot gas temperature sensor
E4-way diverter valve OLow pressure compressor gas temperature sensor
FHigh pressure sensor PRefrigerant receiver
GGas temperature sensor low pressure
evaporator
RLow pressure side Schrader type valve
HLow pressure sensor S Temperature sensor regulator of the refrigeration
circuit

7
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
4.2. Outdoor unit with 2 fans - components
C
A
B
D
E
F
G
H
K
L
M
N O
R
P
SR O
COMPONENTS
АFan K Compressor
BHeat exchanger (evaporator) LLow pressure side Schrader type valve
C. Air inlet temperature sensor MCompressor
D4-way diverter valve NLow pressure compressor gas temperature sensor
ELow pressure sensor ORefrigerant receiver
FGas temperature sensor low pressure
evaporator
PElectronic expansion valve
GHigh pressure sensor RHigh pressure side Schrader type valve
HHigh pressure safety relay S Temperature sensor regulator of the refrigeration
circuit

8
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
4.3. Indoor unit - components
SUNSYSTEM SPLIT R32-0126-1PH
SUNSYSTEM SPLIT R32-0220-3PH
A
B CE D
F
H G
H
GF
K
B CE D
L
COMPONENTS
АWater inlet F Safety valve
BOutlet water (DHW) GRefrigerant R32 - Input
C. Heating water outlet DN25 HRefrigerant R32 - Outlet
D Water drain hole K Controller
ESafety valve soft pipe LCable holes

9
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
5. INSTALLATION
5.1. Outdoor unit with 1 fan - dimensions.
720
430
1049
1094
720
440
961
91
161
133
460
SUNSYSTEM SPLIT R32-0126-1PH

10
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
5.2. Outdoor unit with 2 fans - dimensions.
1000
688
1056
688
443
407
97
166.5
114.5
480
1372
SUNSYSTEM SPLIT R32-0220-3PH
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Sunsystem Wärmepumpe Handbücher
Beliebte Wärmepumpe Handbücher anderer Marken

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Bedienungsanleitung

Dimplex
Dimplex LI 16I-TUR Benutzerhandbuch

Carrier
Carrier WSHP Open v3 Kurzanleitung zur Einrichtung

TGM
TGM CTV14CN018A Bedienungsanleitung

Carrier
Carrier 38MGQ Series Bedienungsanleitung

Kokido
Kokido K2O K880BX/EU Fehlerbehebungshandbuch