Suzuki C10 Merkblatt

1
C10 Color Display
Conguration Manual
P/N 99954-62016

2
All information, illustrations, photographs and
specications contained in this book are based on
the latest product information available at the time
of publication.
Produced by Suzuki Motor of America, Inc.
Technical Publications & Training
Issue Date: June 2016

3
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . 4
Single Engine Conguration . . . . . . . . . . . . . . 4
Initial Power-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Select a Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Set the Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Select the Units to be Displayed . . . . . . . . . . . . . . . . . . . . . . . . . 6
Vessel Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Engine Display Set-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Warning Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Congure Devices on the Network . . . . . . . . . . . . . . . . . . . . . . . . 8
Using the Auto Select Function . . . . . . . . . . . . . . . . . . . . . . . . . 10
Conguring the Fluid Level Sensor . . . . . . . . . . . . . . . . . . . . . . . 12
Setting the Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Calibrating the Fuel Level Sensor. . . . . . . . . . . . . . . . . . . . . . . . 15
GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Suzuki Engine Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Setting Up a Custom Page . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Dual Engine Conguration . . . . . . . . . . . . . . .25
Initial Power-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Select a Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Set the Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Select the Units to be Displayed . . . . . . . . . . . . . . . . . . . . . . . . 27
Vessel Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Engine Display Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Warning Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Congure Devices on the Network . . . . . . . . . . . . . . . . . . . . . . . 31
Conguring the Fluid Level Sensor . . . . . . . . . . . . . . . . . . . . . . . 36
Setting the Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Calibrating the Fuel Level Sensor. . . . . . . . . . . . . . . . . . . . . . . . 39
GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Using the Auto Select Function . . . . . . . . . . . . . . . . . . . . . . . . . 42
Setting Up a Custom Page . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Notes. . . . . . . . . . . . . . . . . . . . . . . . . . .51

25
Dual Engine Conguration
This section shows you how to set-up a dual-engine
conguration using three (3) C10 Color Displays,
two uid level sensors, two engine interfaces, and
one GPS.
This is a typical dual-engine conguration using
three C10 Color Displays. You may choose to
set-up your vessel differently by adding or reducing
the number of accessories.
Initial Power-Up
NOTE:
The C10 should be connected to a dual cable or
Suzuki Precision Control (SPC) motor, and then be
powered up. It is now ready for conguration.
Once the C10 Color Display is turned ON, the
Suzuki “S” logo appears. The C10 then takes 25 –
30 seconds to power-up to the rst screen.
Select a Language
The rst screen to appear is the Select Language
screen — use the arrow buttons to select the
proper language, then press Enter.
Set the Time and Date
NOTE:
With a GPS installed, the local time offset is
automatically populated.

26
1. To set the time and date manually, use the
arrow buttons to select Time format, then
use the arrow buttons to select the 12-hour or
24-hour time format and press Enter.
2. Use the arrow buttons to select Date format,
then set the date and press Enter.
NOTE:
A GPS antenna must be connected in order for the
date to be accurate.
3. After setting the time and date, conrm the
information is correct, then select Next and
press Enter.

27
Select the Units to be Displayed
1. On the Units screen, use the arrow buttons to
select how you want units to be displayed on
the C10, then press Enter.
Vessel Set-up
1. On the Vessel Set-up screen, the C10 will
default to 1 engine and 1 fuel tank.
Use the arrow buttons to select the Number
of Engines box. Then use the arrow buttons
to change it to 2.
If the vessel has two fuel tanks, use the arrow
buttons to select the Number of Fuel Tanks
box. Then use the arrow buttons to change it
to 2.
NOTE:
It is possible to select up to eight engines, but only
two engines can be displayed at any time on the
C10 Color Display.
2. Use the arrow buttons to select Total Fuel
Capacity (gal). Then use the arrow buttons
again to set the Total Fuel Capacity and
press Enter.
In this example, the total fuel capacity has
been set to 60 gallons.

28
3. After conrming the Vessel Setup information,
select OK and press Enter.
Engine Display Conguration
Since you’re working with three C10 Color Displays, it’s important that the information from the port and
starboard engines are displayed correctly, as shown below.
Port C10 Color Display Center C10 Color Display Starboard C10 Color Display
Begin by working with the port C10 rst... (Go to the next page)

29
1. On the port C10 Color Display, use the arrow
buttons to change Engine 1 to Port. Leave
Engine 2 as no engine. Then select OK.
2. On the center C10 Color Display, use the
arrow buttons to change Engine 1 to Port,
and use the arrow buttons to set Engine 2 to
Starboard. Then select OK.
3. On the starboard C10 Color Display, use
the arrow buttons to change Engine 1 to
Starboard and leave Engine 2 as no engine.
Then select OK.

30
Warning Screen
The C10 uses engine fuel ow to calculate the
remaining fuel in the fuel tank.
1. After completing the congurations above,
a Warning screen asks if any fuel has been
added to the vessel since the vessel was
last used.
If you select Yes, the Add Fuel screen will open.
2. It is recommended that you ll the fuel tank to
full capacity for the initial set-up of the fuel level
display in the C10. If you desire, you can add
a uid level sensor to the vessel, and you can
then add a custom page to the C10 to monitor
this information.
When you’re nished, your three C10 Color Displays should appear as shown below.
Port C10 Color Display Center C10 Color Display Starboard C10 Color Display

31
Congure Devices on the Network
With everything physically connected, the rst item
to congure are the engine interfaces.
1. Press the Menu button once.
2. Press Enter to select the Settings menu.
3. Using the arrow buttons to select System and
press Enter.
Andere Handbücher für C10
1
Inhaltsverzeichnis
Andere Suzuki Monitor Handbücher