SVAB Quantum Bedienungsanleitung

Quantum
Installation instruction
DOC-0001404
2020-12-02

Copyright © 2020 SVAB Hydraulik AB All rights reserved
SVAB accepts no responsibility for possible errors in catalogs, brochures and other printed material. SVAB reserves the right to
alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made
without affecting agreed specifications. All trademarks in this material are properties of their respective owners.

Table of Contents
Introduction ........................................................................................................................... 4
General ......................................................................................................................... 4
Support ......................................................................................................................... 5
Environment .................................................................................................................. 5
Certificate of compliance ................................................................................................ 6
Safety ................................................................................................................................... 7
General safety ............................................................................................................... 7
Warning signs ................................................................................................................ 7
Levels of risks ............................................................................................................... 7
System overview ................................................................................................................... 9
Technical description ............................................................................................................ 10
Main parts ................................................................................................................... 10
Quantum Hub ...................................................................................................... 10
TRM (Tool Recognition Module) ............................................................................ 10
Technical data Quantum Hub ........................................................................................ 11
Technical data TRM ..................................................................................................... 13
Function ...................................................................................................................... 14
Installation ........................................................................................................................... 16
Check of delivery ......................................................................................................... 16
Install the Quantum hub ............................................................................................... 16
Install quick coupler switch ........................................................................................... 17
Connecting quick coupler; original and tiltrotator-system ................................................ 18
Connect feed and external excvatator system (when applicable) ..................................... 21
Connecting to tiltrotatorsystem (MACS-RT, XCG2) ......................................................... 22
Mount the TRM ............................................................................................................ 22
Start up ............................................................................................................................... 25
Start up the system ...................................................................................................... 25
Start the Quantum hub ................................................................................................. 25
Register user ............................................................................................................... 27
Register new machine .................................................................................................. 27
Register a new tool ...................................................................................................... 29
Electric diagram ................................................................................................................... 30
Checklist ............................................................................................................................. 31
Quantum
3

Introduction
General
Quantum Tool Recognition is a system for wireless toolrecognition on excavators. This is the only usage
intended for this product. All other usages of this machine, without written permission from SVAB, are
strictly prohibited.
This document gives instructions how to do installation work on a Quantum Tool Recognition system.
SVAB reserves the right to change the contents of this instruction at any time without further notice.
SVAB develops and produces their products in accordance to european legislation and teh macinery
directive 2006/42/EG. The CE marking shows that the system fulfills the directive of electromagnetic
compatibility EMC, RoHS and radiodirective RED.
This installation instruction shall be used in the technical file which will be the base for the final CE
marking of the machine. Therefore, the checklist in this instruction shall be thouroughly performed, com-
pletely filled out and signed by responsible fitter. Save this instruction in the technical file.
The installation of the system referred to in this document is to be performed by experienced personnel.
If there’s unclarities regarding the use, installation, understanding of the system or regarding this docu-
ment - disengage the installation work and contact the system provider for information. By using com-
mon sense you can avoid accidents from happening yourself.
This instruction is protected by copyright and may not be reproduced, distributed or altered. Violation of
the law may lead to prosecutions and fines, imprisonment or duty to pay compensation to the creator /
proprietor.
FCC and ISED
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter
must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter. Changes or modifications to the equipment not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) this device may not cause harmful interference
2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equip-
ment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced
radio/TV technician for help.
RSS Standard
This equipment is exempt from the routine RF exposure evaluation requirement of RSS-102. This equipment should be installed and
operated with a minimum distance of 20 cm between the antenna and the user or bystanders. This device contains licence-exempt
transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Oper-
ation is subject to the following two conditions:
1) This device may not cause interference.
Quantum
4

RSS Standard
2) This device must accept any interference, including interference that may cause undesired operation of the device.
Ce matériel n’est pas sujet à l’évaluation habituelle d’exposition RF selon RSS102. Ce matériel devrait être installé et exploité en
gardant une distance minimale de 20 cm entre l’antenne et l’utilisateur ou les spectateurs. L’émetteur/récepteur exempt de licence
contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables
aux appareils radioexempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1) L’appareil ne doit pas produire de brouillage
2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonc-
tionnement.
CAN ICES-3 (B)/NMB-3(B)
Support
Contact SVAB at:
SVAB, Ulvsättersgatan 2SE-694 35 Hallsberg
Phone: +46 (0)582 152 30 (main) +46 (0)0582 152 33 (Support)
On our website www.svab.se you will find additional information.
Environment
As part of our environmental commitment, we strive for our products to have as little environmental im-
pact as possible throughout the lifecycle. This means there are things to consider during the installation.
• All assembly / disassembly must be done according to national requirements and local regulations.
• Recycle waste ccording to national requirements and local regulations.
Quantum
5

Certificate of compliance
Declaration of Conformity
The manufacturer assures that this product complies with the essential requirements and
provisions in
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
RED Direktiv 2014/53/EU
This declaration is based on the following applied specifications:
EN 13309:2010 Construction machinery – Electromagnetic
compatibility of machines with internal power supply
ISO 13766:2006 Earth-moving machinery - EMC
EN 50581:2012 Restriction of hazardous substances
EN 300328 v2.1.1 Wideband transmission systems
EN 301489-1 v2.1.1 ElectroMagnetic Compatibility (EMC) standard for radio
equipment and services; Part 1
EN 301489-17 v3.1.1 ElectroMagnetic Compatibility (EMC) standard for radio
equipment and services; Part 17
IEC 60950-1:2005 Information technology equipment – Safety
Article number: P-0001441
Product description: Quantum Tool Recognition kit
The manufacturer’s name and address:
SVAB Hydraulik AB
Ulvsättersgatan 2
69435 Hallsberg
Sweden
Hallsberg 2018-04-0–5
______________________________________________________________
Fredrik Eriksson, CEO
Quantum
6

Safety
General safety
Please read the installation instruction carefully before starting any assembly work. Follow the direc-
tions and local regulations.
The system may only be handled by personnel trained for the machine.
Never perform assembly work when the excavator is running.
Make sure that the electric system is powerless before any work on the system commences.
Make sure that the machine’s ROPS structure is not altered, it may affect the CE marking of the ma-
chine.
Only use SVAB original parts. Damage or malfunction caused by parts other than SVAB original parts
are not covered by warranty or product liability.
Warning signs
In our step-by-step instructions, there are warning signs that indicate dangerous situations that may oc-
cur when work is performed when installing our system. It is also explained what the consequences of
the dangerous situation may be.
You who work with the assembly must make a risk assessment in each work situation and follow the
warning that is described on the warning sign to avoid dangerous situations.
Levels of risks
There are three risk levels to take into account:
DANGER
DANGER
Indicates an upcoming hazardous situation which, if not avoided, will result in serious
injury or a fatal accident.
WARNING
WARNING
Indicates a potentially dangerous situation which, if not avoided, can result in serious
injury or fatal accident.
Quantum
7

CAUTION
CAUTION
Indicates a potentially dangerous situation which, if not avoided, can result in less seri-
ous to moderate injuries.
IMPORTANT
NOTE!
This symbol is used when we want to you to pay extra attention or point out things that
can enhance or impair the functionality of your product.
Quantum
8

System overview
Pos Part no Description
1 P-0000963 Quantum Hub
2 P-0000966 TRM
3 P-0001345 Cable supply Quantum Hub
4 P-0001346 Cable Quick coupler signal Quantum Hub
5 P-0000585 Connecting cable Digging system
6 P-0000723 M12 Connector male, straight 5 - pole
7 n/a Quantum App (Google play / App store)
8a 200586 Jumper cable M8, 0.3 m
8b 149209 Jumper cable M8, 1 m
8c 149207 Jumper cable M8, 2 m
9 P-0001304 Cover TRM
Quantum
9

Technical description
Main parts
This is also a test page
Quantum Hub
The hub consists of following main parts:
1. CAN1 / 8-36 VDC
2. I / O
3. CAN2
4. Diodes
5. Name plate
TRM (Tool Recognition Module)
The TRM consists of following main parts:
1. Screw
2. Cover
3. Seal
4. BAttery
5. Lower part
Quantum
10
Andere Handbücher für Quantum
1