Swan Analytical Instruments AMI Bedienungsanleitung

AMI Sample Sequencer
Version 5.00 and higher
A-96.250.661 / 120418
Operator’s Manual

© 2017, SWAN ANALYTISCHE INSTRUMENTE AG, Switzerland, all rights reserved
subject to change without notice.
Customer Support
SWAN and its representatives maintain a fully trained staff of technical specialists
around the world. For any technical question, contact your nearest
SWAN representative, or the manufacturer:
SWAN ANALYTISCHE INSTRUMENTE AG
Studbachstrasse 13
8340 Hinwil
Switzerland
Internet: www.swan.ch
E-mail: [email protected]
Document Status
Title: Monitor AMI Sample Sequencer Operator’s Manual
ID: A-96.250.661
Revision Issue
00 Sept. 2011 First release
01 July 2012 Extended with connection to AMI Silica
02 Feb. 2013 Extended with connection to AMI Phosphate II
03 March 2017 Extended with connection to AMI Silitrace

AMI Sample Sequencer
A-96.250.661 / 120418 1
Table of Contents
1. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1. Warning Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2. General Safety Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1. Measuring Cycle at Batch Measurement . . . . . . . . . . . . . . . . . . . 9
2.1.1 AMI Silica and AMI Phosphate HL . . . . . . . . . . . . . . . . . . . . . . 9
2.2. Measuring Cycle at Continuous Measurement. . . . . . . . . . . . . . . 12
2.2.1 AMI Sodium A and AMI Sodium P . . . . . . . . . . . . . . . . . . . . . . 12
2.2.2 AMI Silitrace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.3. Instrument Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.4. Instrument Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3. Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.1. Installation Check List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.2. Install the AMI Sample Sequencer . . . . . . . . . . . . . . . . . . . . . . . . 24
3.3. Connect Sample and Waste . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.4. Connect the Instrument (Mode <AMI>) . . . . . . . . . . . . . . . . . . . . 31
3.4.1 Connect the I2C Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.4.2 Sample Sequencer Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.4.3 Sample Sequencer Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.4.4 Firmware Settings (Mode <AMI>) . . . . . . . . . . . . . . . . . . . . . . . 35
3.5. Connect the Instrument (Mode <Internal>). . . . . . . . . . . . . . . . . . 36
3.5.1 Connect the Two-Wire Signal Cable . . . . . . . . . . . . . . . . . . . . . 36
3.5.2 Sample Sequencer Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.5.3 Sample Sequencer Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.5.4 Firmware Settings (Mode <Internal>) . . . . . . . . . . . . . . . . . . . . 40
3.6. Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.7. Connection Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.8. Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3.9. Communication, Error Handling . . . . . . . . . . . . . . . . . . . . . . . . . . 44
3.9.1 Mode <AMI> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
3.9.2 Mode <Internal> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4. Instrument Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.1. Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

2A-96.250.661 / 120418
AMI Sample Sequencer
5. Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
5.1. Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
5.2. Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
5.3. Software Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
5.4. Changing Parameters or Values. . . . . . . . . . . . . . . . . . . . . . . . . . 49
6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
6.1. Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
6.2. Stop of Operation for Maintenance. . . . . . . . . . . . . . . . . . . . . . . . 50
6.3. Tube connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6.4. Replacing Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
6.5. Longer Stop of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
7. Error List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
8. Program Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8.1. Messages (Main Menu 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8.2. Diagnostics (Main Menu 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.3. Maintenance (Main Menu 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.4. Operation (Main Menu 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.5. Installation (Main Menu 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
9. Program List and Explanations. . . . . . . . . . . . . . . . . . . . . . . . . 58
1 Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
2 Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
10. Default Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
11. Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
12. Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

AMI Sample Sequencer
Safety Instructions
A-96.250.661 / 120418 3
AMI Sample Sequencer - Operator’s
Manual
This document describes the main steps for instrument setup, oper-
ation and maintenance.
1. Safety Instructions
General The instructions included in this section explain the potential risks
associated with instrument operation and provide important safety
practices designed to minimize these risks.
If you carefully follow the information contained in this section, you
can protect yourself from hazards and create a safer work environ-
ment.
More safety instructions are given throughout this manual, at the
respective locations where observation is most important.
Strictly follow all safety instructions in this publication.
Target
audience
Operator: Qualified person who uses the equipment
for its intended purpose.
Instrument operation requires thorough knowledge of applications,
instrument functions and software program as well as all applicable
safety rules and regulations.
OM Location The AMI Operator’s Manual shall be kept in proximity of the instru-
ment.
Qualification,
Training
To be qualified for instrument installation and operation, you must:
read and understand the instructions in this manual as well as
the Material Safety Data Sheets.
know the relevant safety rules and regulations.

4A-96.250.661 / 120418
AMI Sample Sequencer
Safety Instructions
1.1. Warning Notices
The symbols used for safety-related notices have the following sig-
nificance:
DANGER
Severe injuries or death will result if such warnings are ignored.
Follow the prevention instructions carefully.
WARNING
Severe injuries or damage to the equipment can occur if such
warnings are ignored.
Follow the prevention instructions carefully.
CAUTION
Damage to the equipment, minor injury, malfunctions or incor-
rect process can be the consequence if such warnings are ig-
nored.
Follow the prevention instructions carefully.
Mandatory
Signs
The importance of the mandatory signs in this manual.
Safety goggles
Safety gloves

AMI Sample Sequencer
Safety Instructions
A-96.250.661 / 120418 5
Warning Signs The importance of the warning signs in this manual.
Electrical shock hazard
Corrosive
Harmful to health
Flammable
Warning general
Attention general

6A-96.250.661 / 120418
AMI Sample Sequencer
Safety Instructions
1.2. General Safety Regulations
Legal
Requirements
The user is responsible for proper system operation.
All precautions must be followed to ensure safe operation
of the instrument.
Spare Parts
and
Disposables
Use only official SWAN spare parts and disposables. If other parts
are used during the normal warranty period, the manufacturer’s
warranty is voided.
Modifications Modifications and instrument upgrades shall only be carried out by
an authorized Service Technician. SWAN will not accept responsi-
bility for any claim resulting from unauthorized modification or alter-
ation.
WARNING
Electrical Shock Hazard
If proper operation is no longer possible, the instrument must be
disconnected from all power lines, and measures must be taken
to prevent inadvertent operation.
To prevent from electrical shock, always make sure that the
ground wire is connected.
Service shall be performed by authorized personnel only.
Whenever electronic service is required, disconnect instru-
ment power and power of devices connected to.
–relay 1,
–relay 2,
– alarm relay
WARNING
For safe instrument installation and operation you must read
and understand the instructions in this manual.
WARNING
Only SWAN trained and authorized personnel shall perform the
tasks described in this document.

AMI Sample Sequencer
Product Description
A-96.250.661 / 120418 7
2. Product Description
Application
Range
The AMI Sample Sequencer is a complete system for the automat-
ic, continuous multiplexing of up to six sample streams to one pro-
cess analyzer. The AMI Sample Sequencer can be connected to
an:
AMI Phosphate HL
AMI Silica
AMI Silitrace
AMI Sodium A
AMI Sodium P
Operating
Modes
The AMI Sample Sequencer provides the following two operating
modes
AMI
Set the AMI Sample Sequencer to the mode <AMI> if it is con-
nected to an AMI Phosphate HL, AMI Silica or AMI Silitrace. In
this operating mode the AMI Sample Sequencer works as
slave, either of the analyzer or of an external PLC. Communi-
cation between the instruments takes place via I
2
C interface.
For further information see
Connect the I2C Bus, p. 31
.
Internal
Set the AMI Sample Sequencer to the mode <Internal> if it is
connected to an AMI Sodium A or AMI Sodium P. In this oper-
ating mode the AMI Sample Sequencer works as master. It
switches the sample streams according to the programmed
cycle time. There is no communication between the instru-
ments, only measuring values are transferred via signal out-
puts 1 and 2 of the analyzer to the signal inputs 1 and 2 of the
AMI Sample Sequencer. For further information see
Sample Sequencer Inputs, p. 37
.
Signal
Outputs
6 current outputs to transfer the measuring values of the AMI trans-
mitter to a PLC device.
Relay 6 signal outputs for indication of the 6-way valve position.
1 signal output for flow alarm.
Inputs 6 signal inputs to override programmed measuring sequences, by
activating or deactivating an input. The functionality depends on the
settings of the instruments.

8A-96.250.661 / 120418
AMI Sample Sequencer
Product Description
Safety
Features
No data loss after power failure. All data is saved in non-volatile
memory. Over voltage protection of in- and outputs. Galvanic sepa-
ration of measuring inputs and signal outputs.
Fluidics The sample enters the flow cell blocks [C, D, E] via the sample in-
lets [I]. Each sample inlet is equipped with a flow regulating valve
[G]. The sample flows through the active sample line via 6-way
valve [A] and flow meter [F] to the instrument. Excessive sample
(e.g. inactive sample lines) flows via overflow [H] to the atmospher-
ic drain [J].
A
B
C
D
6-way valve
Sample outlet
Flow cell block with sample
inlet 1 and 2
Flow cell block with sample
inlet 3 and 4
E
F
G
H
I
J
Flow cell block with sample
inlet 5 and 6
Flow meter
Flow regulating valve
Overflow
Sample inlets 1–6
Atmospheric drain
1
IIIIII
34
5
7
6
2
A
B
C
G
HHH
JJJ
GG GG G
DEF
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Swan Analytical Instruments Aufnahmegeräte Handbücher
Beliebte Aufnahmegeräte Handbücher anderer Marken

Strymon
Strymon NIGHTSKY Bedienungsanleitung

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Bedienungsanleitung

Tews Technologies
Tews Technologies TPMC465 Bedienungsanleitung

Honeywell
Honeywell Excel 50 Bedienungsanleitung

SeaLevel
SeaLevel COMM+8.LPCI Bedienungsanleitung

Arturia
Arturia AUDIOFUSE STUDIO Bedienungsanleitung