Switrace LOG-IC 360 BT Bedienungsanleitung

1
• Temperature
• Temperature + Humidity
Switrace SA | Via F.Catenazzi 5 | 6850 Mendrisio | Switzerland
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
in partnership with
Revolutionize Your Cold Chain
Bluetooth Logger
Users Guide
switrace.com | +41 91 646 18 74 | [email protected]

Table of Contents
LOG-IC® 360 BT GETTING STARTED ................................................................ 3-5
Identifying Your Logger Type ........................................................................................................... 3
Downloading the LOG-IC 360 BT App................................................................................................ 3
Turning Logger On ........................................................................................................................... 3
Navigation ....................................................................................................................................... 4 - 5
Display Abbreviations ...................................................................................................................... 5
DEFAULT SETTINGS AND PRE-CONFIGURED PROFILES ..................................... 6-7
Edit Profile Defaults ........................................................................................................................ 6
Application Functionality & Information .......................................................................................... 6
Deploy A Pre-Configured Profile ...................................................................................................... 7
Deleting A Profile ............................................................................................................................. 7
CREATING AND USING A CUSTOM PROFILE...................................................... 8-11
Creating a Custom Profile ................................................................................................................ 8 - 9
Deploy a Custom Profile................................................................................................................... 10
Deleting a Custom Profile ................................................................................................................ 10
Click To Deploy A Profile To Any Device............................................................................................. 11
Scan To Deploy A Profile To Any Device ............................................................................................ 11
CREATING AND USING A PROFILE TO A BATCH OR GROUP ................................. 12
Creating a Batch and Deploying a Profile ......................................................................................... 12
Creating a Group and Deploying a Profile ........................................................................................ 12
UTILIZING USER MARKS ............................................................................... 13
User Marks ...................................................................................................................................... 13
READING THE DISPLAY OF A BLUETOOTH LOGGER........................................... 14
Reading the Display ......................................................................................................................... 14
DATA DOWNLOAD AND HISTORY .................................................................... 15-18
Data Download ................................................................................................................................... 15
Click to Download............................................................................................................................ 15
Scan to Download............................................................................................................................ 16
Share the Data................................................................................................................................. 16
Batch Download and Sharing ........................................................................................................... 17
Group Download and Sharing .......................................................................................................... 18
History ............................................................................................................................................ 18
LOGGER MONITORING.................................................................................. 19
Stop Monitoring a Logger................................................................................................................. 19
Turning Logger O ........................................................................................................................... 19
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
2 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

IDENTIFYING YOUR LOGGER TYPE
ATI oers two versions of the LOG-IC 360 BT
Logger including:
1) Temperature only
2) Temperature + Relative Humidity
DOWNLOADING THE LOG-IC 360 BT APP
Step 1) Go to apps.americanthermal.com.
Step 2) Select the Google Play or App Store
based on your device.
Step 3) Select “Open.”
Step 4) Download the app.
The LOG-IC 360 icon will appear on your smart
device home screen.
TURNING LOGGER ON
A logger is o and inactive when the screen is blank. To
turn on the logger, press and hold the Power button
for 2 seconds. The display will Power on with the letters
“rdY”. The logger is now on but not actively logging.
LOG-IC® 360 BT
Getting Started
Temperature Temperature + RH
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
3 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

NAVIGATION
When opening the LOG-IC 360 BT App, you will be
prompted with these options:
PROFILE
CREATE
Create a custom profile for logging.
EDIT
Edit any existing profile including pre-configured
and custom.
DEPLOY
Choose a pre-configured or custom profile to deploy.
DATA
DOWNLOAD
See all active LOG-IC 360 BT loggers in range.
FIXED ASSET
View a list of loggers in range with status and
temperature data.
HISTORY
View a list of all LOG-IC BT loggers that have been
connected to your smart device.
CONFIGURATION
SETTINGS
Set default profile settings, adjust App functionality
and view the App details.
LOG-IC® 360 BT
Getting Started
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
4 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

NAVIGATION
TOGGLE BETWEEN SINGLE AND BATCH/GROUP MODE
SINGLE MODE
BATCH/GROUP
UNIVERSAL FUNCTIONS
CLICK TO CONNECT
OPEN LOGGER SCANNER
RESTART SCANNER
BATCH/GROUP FUNCTIONS
ADD/CREATE GROUP
DOWNLOAD/DEPLOY
SHOW/HIDE LIST
SHOW GROUP INFORMATION
DISPLAY ABBREVIATIONS
bP: Button Press
AP: Airplane Mode
So: Soak Mode
rdY: Ready
LOG-IC® 360 BT
Getting Started
SINGLE MODE
BATCH/GROUP MODE (SHOW LIST)
BATCH/GROUP MODE (HIDE LIST)
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
5 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

EDIT PROFILE DEFAULTS
There are a number of default properties that can
easily be adjusted for consistent programming.
Step 1) Select
Step 2) Adjust the profile defaults including:
• Start Mode
• Soak Time
• Units of Measure
• Airplane Mode
• Log Interval
• High Speed Logging
• User Notes
• Circular Buer
• Stop Monitoring
The selections will now be your default options when
creating additional profiles.
APPLICATION FUNCTIONALITY
The LOG-IC 360 BT App can be customized for
your usability.
Step 1) Select
Step 2) Click on each option to adjust settings:
• Vibrate on Connect
• Read Range
• Display Units
• Firmware Notifications
• Legacy Scanning
• Date/Time Display Option
• Graph Simplification
APPLICATION INFORMATION
You can view the current App and Logger Firmware
version within this section.
SETTINGS
SETTINGS
Default Settings and
Pre-Configured Profiles
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
6 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

DEPLOY A PRE-CONFIGURED PROFILE
The LOG-IC 360 BT App includes pre-configured profiles
that can be deployed instantly to your BT device.
Step 1) Be sure your device is on, reading rdY.
• If not, hold the Power button
for 2 seconds.
Step 2) Select
Step 3) Select the profile of your choice.
Step 4)The App will begin scanning for BT
devices within range that are not
currently logging.
Step 5) Select your logger.
• If you are unsure which logger to choose,
click and release the Power button
• The background of the correct logger
will turn green.
Step 6) If you selected notes in your configuration, you
will be prompted to type these notes or scan a
QR code for details.
Step 7) The app will read DEPLOYED SUCCESSFULLY
and the current temperature or “SO” for soak
will be displayed on the logger screen.
The device will show as ACTIVE in the Scanner screen of
the App.
DELETING A PROFILE
To delete a profile, press and hold on the profile for
2 seconds and select Delete.
To stop a logger or turn it o, see page 18.
DEPLOY
Default Settings and
Pre-Configured Profiles
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
7 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

CREATING A CUSTOM PROFILE FOR
TEMPERATURE ONLY DEVICES
Step 1) Select
Step 2) You can then select your parameters:
• Name Profile.
• Set Temperature Alarms.
- Select the red arrow next to Not Used
- Select what type of of temperature you’d like
to monitor - Instant, Cumulative or Continuous
- Select whether you want to monitor a
temperature above or below a certain threshold
- Select your temperature threshold
- Set the humidity option as Not Used
- Set the time
- Select the blue OK
• Continue this process for up to 4 alarms.
• Within the Details section, you can set:
- Start Mode
- Soak Time
- Units of Measure
- Airplane Mode
- Log Interval
- High Speed Logging
- User Notes
- Circular Buer - Older data will be overwritten
with new data once max time is met.
- Stop Monitoring Button - A long, 6-second
press of the power button will stop the
logger from recording.
Creating a Custom Profile
for Temperature Devices
CREATE
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
8 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

Creating a Custom Profile
for Temp + RH Devices
CREATE
CREATING A CUSTOM PROFILE
FOR TEMPERATURE + RH DEVICE
Step 1) Select
Step 2) You can then select your parameters:
• Name Profile.
• Set Temperature Alarms.
- Select the red arrow next to Not Used
- Select what type of temperature you’d like
to monitor - Instant, Cumulative or Continuous
- Select whether you want to monitor a
temperature above or below a certain threshold
- Select your temperature threshold
- Set the critical humidity level or Not Used
- Set the time
- Select the blue OK
• Continue this process for up to 4 alarms.
• Within the Details section, you can set:
- Start Mode
- Soak Time
- Units of Measure
- Airplane Mode
- Log Interval
- High Speed Logging
- User Notes
- Circular Buer - Older data will be overwritten
with new data once max time is met.
- Stop Monitoring Button - A long, 6-second
press of the power button will stop the
logger from recording.
*High speed logging will allow your logger to move to
1-minute sampling periods automatically aer reaching
a temperature excursion. This will provide you with
detailed data about when the excursions occur.
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
9 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments

DEPLOY A CUSTOM PROFILE
Step 1) Select
Step 2) Select the custom profile.
Step 3) The App will begin scanning for BT devices
within range that are not currently logging.
Step 4) Select your logger.
• If you are unsure which logger to choose,
click and release the Power button
• The background of the correct logger
will turn green.
Step 5) If you selected notes in your configuration, you
will be prompted to type these notes or scan a
barcode or QR code for details.
Step 6) The app will read DEPLOYED SUCCESSFULLY
and the current temperature or “SO” for soak
will be displayed on the logger screen.
The device will show as ACTIVE in the Scanner screen
of the app.
DELETING A CUSTOM PROFILE
To delete a profile, press and hold on the profile for
2 seconds and select Delete.
To stop a logger or turn it o, see page 18.
Deploy a
Custom Profile
DEPLOY
© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.
switrace.com | +41 91 646 18 74 | [email protected]
10 ATI20-075 LOG-IC® BT & BT RH Users Guide
in partnership with American Thermal Instruments
Inhaltsverzeichnis
Andere Switrace Datenlogger Handbücher




















