TAG HDIT 2U Bedienungsanleitung

Reference Manual
22355 TAG WAY
Dulles, VA 20166-9310
Technical Support: (877) TAG-TECH
+1 (703) 406-4516
tag.com
HDIT 2U 1GHz PIII Server

TAG®Contact Information:
Mailing Address:
Technology Advancement Group®, Inc.
22355 TAG WAY
Dulles,VA 20166-9310
USA
Telephone Numbers:
Headquarters
+1 (703) 406-3000
Toll-Free 1 (800) TAG-POWER (CONUS Only)
0800 - 1700 Eastern Time (USA)
Tech Support
+1 (703) 406-4516
Toll-Free 1 (877) TAG-TECH(CONUS Only)
24Hours-A-Day,365Days-A-Year
Internet:
Web Site
tag.com
E-Mail
8
When servicing the HDIT 2U 1GHZ PIII SERVER, disconnect the unit from the
power source, and remove the power cord (See Page 6). All 22 (See Figure 9) screws
need to be removed from the Top Access Panel to service the unit.
Note: The two screws are located on the Front Panel of the
HDIT 2U 1GHZ PIII SERVER. Failure to remove those will result in damag-
ing the Top
Access Panel.
The HDIT 2U 1GHZ PIII SERVER should never be serviced without contacting TAG’s
Tactical Technical Support Team first.
Top Access Removal Instructions
NT 4.0 Server Load Instructions
StepsforloadingWindows NTServer 4.0on TAG2U RAIDServers
1) Boot the computer with a bootable floppy (ie Windows 95 startup disk).
(disk must contain Command.Com and Fdisk).
2) Execute Fdisk and create a 4GB partition on the Hard Drive.
3) Remove the bootable floppy and put the NT 4.0 Server CD in the Drive.
4) Change the boot priority (in CMOS) so that the CD-ROM is now the primary
boot device.
5) When NT 4.0 Server begins to load press the <F6> key.
6) Type <S> and load the MegaRAID drivers for the RAID card.
7) After drivers have loaded hit <Enter>.
8) On the 1st Setup screen hit <Enter>.
9) Type <S> and load the Adaptec 7800 Ver3.02 drivers for NT. When prompted
select the U2 drivers for NT4.
10) Allow NT 4.0 Server to continue the load.
11) Delete the 4GB partition you created (with Fdisk).
12) Install NT 4.0 Server into the 4GB of unpartitioned space now recognized
by NT 4.0 Server.
13) Choose NTFS as your file system.
14) Follow all screen prompts until NT 4.0 Server asks to be rebooted.
15) When NT 4.0 Server resumes Setup (now in GUI) follow all screen prompts.
16) Install network drivers for the onboard network card (from diskette).
17) Finish NT 4.0 Server load.
Figure 9

Table of Contents:
Features 1
FrontPanel
FrontPanel-Power&ResetSwitches 2
FrontPanel-CD-ROM 3
FrontPanel-RemovableHardDrives 4
RearPanel
RearPanel 5
RearPanel-I/OPorts 5
RearPanel-PowerSupply 6
SCSIIDs 7
TopAccess Removal 8
WindowsNT4.0LoadInstructions 8
©2001 Technology Advancement Group, Inc. All rights reserved.
TechnologyAdvancementGroup,TAG,HDIT, andtheTAG Ballgraphicare trademarksorregis-
teredtrademarksofTechnologyAdvancementGroup,Inc. Thismanualand/oritscontentsmay
notbeduplicated without written permissionofTechnologyAdvancementGroup, Inc.
Printedin theUSA
Figures:
Figure1 FrontPanelPower&ResetSwitches 2
Figure2 PCMCIAReader(IfEquipped) 3
Figure3 RemovableHardDrive 4
Figure4 Removable HardDrive Exposed 4
Figure5 RearPanel 5
Figure6 RearPanel-I/OPorts 5
Figure7 RearPanel-PowerSupply 6
Figure8 SCSI IDs 7
Figure9 TopAccessPanelRemoval 8
7
The HDIT 2U 1GHZ PIII SERVER is featured with several SCSI devices, each with
its own unique SCSI ID. The following is a list of all SCSI peripherals and their respec-
tive SCSI IDs.
SCSI IDs
SCSI ID Device
RAIDController
0 Hard Drive(Lower Left)
1 HardDrive(UpperLeft)
2 HardDrive(UpperRight)
3 HardDrive(LowerRight)
SCSI Controller
3 PCMCIA Reader -(IfEquipped)
Figure 8

Features
The HDIT 2U 1GHZ PIII SERVER, as all products in the HDIT product line, is
specifically designed to provide unsurpassed performance and reliability where rack
space is very limited. The HDIT 2U 1GHZ PIII SERVER comes in a variety of configura-
tions and may have the following features:
•2U heavy-duty industrialized 90-mil. rack-mount server chassis (24”x19”x3.5”)
•28” slide rails with 6” extended
•300W auto-switching power supply
•2 high performance blowers for & thermal dissipation across the HDIT chassis
•1 MHz. Pentium®III processor with 512KB high-performance cache
•Genuine Intel®motherboard featuring the L440GX+ chipset
•On-board dual-channel SCSI controller with SCSI Out (If Equipped)
•On-board 2MB SGRAM video adapter
•On-board 100MB Fast Ethernet card
•512MB 100MHz. SDRAM/ECC RAM, expandable to 2GB
•(3) 18GB Ultra-Wide SCSI, hot-swap hard drives in a metal carrier & receiver
•(1) 18GB Ultra-Wide SCSI, hot-spare hard drive in a metal carrier & receiver
•PCI Ultra-160 SCSI RAID Controller with 32MB RAID Cache
•Low-Profile Internal CD-ROM
•External SCSI port
•Fortezza Compliant PCMCIA Reader (IfEquipped)
•3.5” 1.44MB Floppy Drive
•1 year parts & labor warranty, and lifetime 24x7 telephone technical support
1
Rear Panel - Power Supply
Situated on the back of the HDIT 2U 1GHZ PIII SERVER is an Auto-Switching
115/230VAC power supply,(See Figure 7).The system main power switch is located
just beneath the power supply’s cooling fan. Turn off the main power switch and
remove the power cord from the HDIT 2U 1GHZ PIII SERVER before servicing or
moving the unit.
Rear Panel - Power Supply Specifications
INPUT: 115/230VAC 60/50Hz 10/5A
OUTPUT: 300W (Total Combined MAX)
(+5V/+3.3V Total MAX 140W)
OUTPUT: +5VDC @ 30A +12VDC @ 14A
-5VDC @ 0.3A -12VDC @ 1.0A
+3.3VDC @ 22A +5VDC @ 0.2A
6
Figure 7

Front Panel - Power & Reset Switches
The HDIT 2U 1GHZ PIII SERVER features 2 switches mounted centrally on the
front panel. To power up the HDIT 2U 1GHZ PIII SERVER, press hold the power
switch. The Power LED (green) will then glow indicating power is being supplied to the
unit.
NOTE: If the unit does not power up, check the power connections
and the main power switch on the back panel below the power
supply.
The second switch is the system reset switch. Press the switch to reset the HDIT 2U
1GHZ PIII SERVER,(See Figure 1).
2
Rear Panel
The connectors for all of the external peripherals are located on the left side of the
rear panel of the HDIT 2U 1GHZ PIII SERVER,(See Figures 5 & 6). Some of the HDIT
2U 1GHZ PIII SERVER units come with a external SCSI Out connector. When
connecting peripherals, make sure the connectors are well seated in the port.
The main system power switch is located below the power supply on the
right side (See Figure 7). When mounting the HDIT 2U 1GHZ PIII SERVER into a rack,
please make sure all connections are secured in their appropriate ports before sliding
the unit into the rack.
5Figure 1
Figure 5
Figure 6

The HDIT 2U 1GHZ PIII SERVER is equipped with four removable 9GB Ultra 2
Wide SCSI LVD hard drives,(See Figures 1, 3 & 4).Refer to page 7 for the SCSI IDs.
NOTE: If you are unsure of the system configuration, power down the unit
to remove either drive.
To remove either drive, insert the hard drive module key and turn the keylock
clockwise to the unlocked position. Grab the handle and slide the drive out. Insert
the replacement drive into the HDIT 2U 1GHZ PIII SERVER and turn the keylock
counter-clockwise to the locked position.
Front Panel - Removable Hard Drives
43
Front Panel - CD-ROM
The HDIT 2U 1GHZ PIII SERVER is equipped with a SCSI CD-ROM,(See Figure 1).
To load a CD, press the CD tray eject button. Place the CD on the CD tray, and press
the tray eject button again. The CD activity light will illuminate intermittently, as the CD
is read.
Front Panel - PCMCIA Reader (If Equipped)
The HDIT 650-27R may be equipped with a Fortezza CompliantPCMCIA reader
located on the front panel. TAG has configured the PCMCIA reader with SCSI #3. The
reader contains two slots which are designed to accept Type I, Type II, and Type III
card types.
The PCMCIA reader is equipped with four LED indicators and two card eject
buttons,( See Figure 2). The upper card eject button is on the left side of the slots
and the lower card eject button is on the right side of the slots.
The green LED on the left side of the unit indicates power is being supplied to that
unit. The red LED below the power indicator, positioned below the power indicator,
will illuminate for one of the following three reasons:
•Nocardis inserted. When a card isinsertedcorrectly,the red LED turnsoff.
•Aslotisaccessedinwhichnocard is inserted. The red LED remains lit until the
cardintheotherslotisaccessed.
•Acardisinserted,butitcannot beaccessedbythePCMCIAreader.This errorcan
havevariouscauses;for example, the unit is attempting towritedatatoa write-
protected,aread-only, or an unknown I/Ocardora hardwareerror existsonthe
card.
The amber LEDs, on the right side of the PCMCIA reader, are the access indicators
for the upper and lower slots. The LED will illuminate when there is data activity on
the PCMCIA bus.
Figure 3
Figure 4
Figure 2
Inhaltsverzeichnis
Andere TAG Server Handbücher

TAG
TAG SV-1002-X2 Bedienungsanleitung

TAG
TAG SV-4103-X4 Bedienungsanleitung

TAG
TAG SV-4102-X214 Bedienungsanleitung

TAG
TAG CENTRIX SV-2000-X2 Bedienungsanleitung

TAG
TAG SV-2002-X2 Bedienungsanleitung

TAG
TAG SV-4002-X2 Bedienungsanleitung

TAG
TAG SV-2000-IX Bedienungsanleitung

TAG
TAG SV-2003-X2 Bedienungsanleitung
Beliebte Server Handbücher anderer Marken

iRobo
iRobo IPC2U Bedienungsanleitung

Nortel
Nortel 1000 Con?guration guide Bedienungsanleitung

Asus
Asus AP7500 Bedienungs- und Wartungshandbuch

Avid Technology
Avid Technology AirSpeed 5000 Bedienungsanleitung

HP
HP Integrity rx2600 Installationsanleitung

Milestone
Milestone Husky IVO 350T Bedienungsanleitung