Targa POWERFIX Profi PEK 2.3 A1 Merkblatt



V 1.1
English.................................................................................2
Polski ................................................................................20
Magyar .............................................................................39
Česky ................................................................................58
Slovenčina.........................................................................77
Deutsch..............................................................................95

PowerFix PEK 2.3 A1
2 - English
Table of contents
Introduction.............................................................................. 3
Intended use............................................................................. 4
Supplied items.......................................................................... 5
Technical data........................................................................... 6
Safety instructions .................................................................... 6
First use .................................................................................. 10
Overview of the controls and button functions...............................................10
Inserting/replacing the batteries......................................................................11
Attaching/detaching the gooseneck...............................................................12
Use of the device ..............................................................................................13
Switching the endoscope camera on and off ............................................13
Lighting..........................................................................................................13
Screen brightness .........................................................................................13
Changing the display...................................................................................13
Video-out function.........................................................................................13
Screen displays.............................................................................................15
Fitting the attachments..................................................................................16
Storage when not in use...................................................................................17
Troubleshooting ..................................................................... 17
Cleaning ................................................................................. 17
Environmental and disposal information ................................ 17
Conformity information .......................................................... 18
Copyright ............................................................................... 18
Warranty and servicing advice............................................... 18

PowerFix PEK 2.3 A1
English - 3
Introduction
Thank you for purchasing the endoscope camera PEK 2.3 A1. The endoscope
camera with a flexible gooseneck and adjustable LED lighting can be used in
inaccessible places to aid inspection and fault analysis. You can use the built-in
video-out port, for example, to display the image on a TV.
Please read the following instructions carefully before using the device,
even if you are familiar with the use of electronic devices.
Store these instructions in a safe place for future reference. If you pass on
the device to someone else, be sure to always include these instructions.
The operating instructions are an integral part of the device.
Symbols used and their meaning
DANGER! This symbol in conjunction with the "danger" note
indicates an imminent dangerous situation which, if not
prevented, could result in serious injury or even death.
WARNING! This symbol in conjunction with the "warning"
note indicates important information for safe use of the device
and the safety of the user.
This symbol indicates other important information on the topic.

PowerFix PEK 2.3 A1
4 - English
Intended use
The endoscope camera PEK 2.3 A1 is an optical inspection device which is not
approved for medical use.
The endoscope camera with a gooseneck and LED lighting can be used in
inaccessible places to aid inspection and fault analysis.
The gooseneck is watertight and suitable for use in aqueous liquids provided
the immersion depth does not exceed 90cm. Please note that only the
gooseneck may be exposed to moisture, and not the control panel (TFT screen
with handle). Use of the device in oils, lyes or acids is not permitted.
DANGER! The endoscope camera is not suitable for medical
applications or use and should never be inserted into body
orifices.
The manufacturer does not assume any liability if
The endoscope camera is not used in accordance with its intended
purpose.
Material damage or personal injuries are caused by incorrect use of the
endoscope camera or non-observance of these instructions.
The endoscope camera is damaged, incomplete or modified prior to
connection and use.
This is an information technology device. It may only be used for private
purposes, but not for industrial, commercial or medical purposes.
Please observe the regulations and laws in the country of use.

PowerFix PEK 2.3 A1
English - 5
Supplied items
Remove the device and all accessories from the packaging. Remove all
packaging material and check that all parts are complete and undamaged. In
the event of an incomplete or damaged delivery, please contact the
manufacturer.
A Endoscope camera PowerFix PEK 2.3 A1
B Hard shell case
C Flexible gooseneck with camera head and LED lighting
D Magnet camera attachment
E Hook camera attachment
F Double hook camera attachment
G Mirror camera attachment
H 2 attachment fixtures
I 4 x 1.5V AA / LR6 batteries
J These operating instructions (symbolic representation)

PowerFix PEK 2.3 A1
6 - English
Technical data
TFT screen 5.9cm / 2.31" screen size
Resolution 960 (RGB) x 240 or
320 (pixels) x 240
Camera lighting 4 white LEDs
(with 8-stage adjustment)
Illuminated display with 8-stage adjustment of
brightness
Power supply 6V
4 x 1.5V AA / LR6 batteries
Run time approx. 8 hours
Ambient/outside temperature -10°C to +50°C
Permissible storage conditions -10°C to +50°C, max. 85% rel.
air humidity (non-condensing)
Total length of gooseneck with
camera head and adapter base
approx. 1,050mm
Endoscope camera diameter 8mm
Flexible gooseneck Ingress Protection
Rating
IP 67
Weight (including batteries) approx. 407 g
Dimensions of hand unit (W x H x D) 257 x 92 x 44mm
The technical data and design may be changed without notification.
Safety instructions
General information
DANGER! The endoscope camera is not approved for medical
use! There is a risk of a potentially fatal injury!

PowerFix PEK 2.3 A1
English - 7
If smoke is produced, or there are any unusual sounds or smells, the
device should not be used until it has been inspected by authorised
service personnel. In this case, switch off the device immediately and
remove the batteries.
Use of the camera on humans and animals is not permitted. The user,
and not the manufacturer, is responsible for any personal injury or
material damage resulting from incorrect use.
DANGER! Children and persons with disabilities
Electrical devices do not belong in the hands of children. Persons with limited
physical, sensory or mental abilities should also only use electrical devices
appropriately. Never allow children or persons with disabilities to use electrical
devices unsupervised unless they have been instructed accordingly or are
supervised by a person responsible for their safety. Children should always be
supervised to ensure that they do not play with this device.
Always keep plastic packaging out of reach also.
It poses a suffocation risk!
DANGER! Screen
Do not exert any pressure on the display and keep sharp objects away from
the display. There is a risk of injury if the display is broken. Wear gloves if you
are gathering broken parts and contact the manufacturer if necessary. If the
screen becomes scratched or damaged in any way, take special care to
ensure that no liquid leaks from the screen.

PowerFix PEK 2.3 A1
8 - English
If liquid has leaked, follow the instructions below:
If the liquid comes into contact with your skin, wipe it off with a clean
cloth and rinse the area of contact with a large amount of water.
Consult a doctor if necessary.
If the liquid comes into contact with your eyes, rinse them with running
water for at least 15 minutes and then go to a hospital immediately.
Consult a doctor if necessary.
If you swallow the liquid, first rinse your mouth with water and then drink
a large amount of water. Consult a doctor immediately!
WARNING! Operational safety
The housing of the endoscope camera must not be opened because it does not
contain any parts that require maintenance. Ensure that the device is not
subject to extreme temperature fluctuations, since this could result in
condensation and electrical short circuits. If the device was subjected to
extreme temperature fluctuations, however, wait (approx. 2 hours) until the
device has reached ambient temperature before use.
DANGER! Batteries
Always ensure correct polarity of the batteries. Please note the markings on the
batteries and in the battery compartment. Never try to recharge batteries and
never throw them into an open fire. Never use different batteries (old and new,
alkaline and carbon, etc.) at the same time. Remove the batteries if you will not
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Sprachen:

















