TELEVAC DS-10 Bedienungsanleitung

Remote Digital Display Unit
DS-10
2-7900-098
Instruction Manual
TELEVAC
A DIVISION OF THE FREDERICKS COMPANY
2400 PHILMONT AVE.
HUNTINGDONVALLEY, PA 19006
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

1. Installation
Panel thickness:1 -10 mm
9.2
8.2
100
61.6
44.8
48
(Unit: mm)
48
DS-
10
25
25
25
45
+0.6
+0.6
0
0
L1
n: number of unit (2
≦n≦
6)
45
L1=(48×n-3)
44.8
25
+0.6
0
45
+0.6
0
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

2. Wiring
pin
function
IN/OUT
explanation
1 +24V INPUT 24V DC Input
2 +24V COM 24V DC Common
4 SP1
OUTPUT
Setpoint 1 Common
5 SP1 NO Setpoint 1 NO
6 SP1 NC Setpoint 1 NC
7SP2
OUTPUT
Setpoint 2 NO
8SP3 Setpoint 3 NO
9SP2, SP3 COM Setpoint 2,3 Common
11 ANALOG IN+INPUT Analog Input +
12 ANALOG IN-Analog input -
24V
NO
10
NO
0~10V
-
SP1
NO
NC
+
-
+
DC
13
14
15
18
16
17
3
6
5
4
2
1
12
11
9
7
8
SP3
SP2
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

3. Specification
Display
Main display
:
4 digit LED(Green)
display range
:
4.0
×
10-13
~
4.0
×
107
(0.3 to 10.3Vinput)
Display= 10{(V-6.5)/0.5}
over scale
:
“oooo” blinking when input is over 10.3V
under scale
:
“uuuu” blinking when input is under 0.3V
Sub display
:
4 digit LED(orange) charctor dispaly
:
set points status indicator (point LED Green)
Input signal
Input voltage
:
DC 0-10V
Sampling interval
:
0.5sec
Input impedance
:
5.1kohm
Setpoint
Setpoint 1
:
AC250V 3A ,1c contact
Setpoint 2,3
:
AC250V 1A ,1a contact
Ambient
Temperature
:
0 - 50
℃
Humidity
:
45 -85%RH
Power
Input voltage
:
DC21.6 - 26.4V(nominal 24V)
power consumption
:
max 160mA
physical property
weight
:
150g
size
:
48
×
48
×
100mm
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

4. Panel description
Function
Description
1 : Data display(green)
data and parameters are displayed
2 : Mode display(orange)
parameters are displayed
3: Setpoint indicator(red)
(SP1, SP2, SP3)
Lit when pressure went below the setpoints
4: Set key
call and enter parameters
5: Shift key
move display digit
6: Down key
decrease displayed values
7: Up key
increase displayed values
5. Operation
When power is turned on model number and software version number are displayed for 4 seconds
then go to measure mode.
4 seconds
DS- 10
SET
SP2SP1 SP3
×10
SET
SP1 SP2 SP3
DS- 10
×10
SP1
SET
DS- 10
×10
SP3SP2
model number
soft version
measure mode
SP3
③
①
×10
SP1 SP2
SET
⑥
②
⑤④
DS- 10
⑦
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

5. Operation (cont.)
(1) Measure mode
3.2
×
102Pa
3.2
×
10-2 Pa
(2) Program mode
Push set key for program mode. Use shift key to move changing digit. Use up
and down key to change the value. Push set key to register the value.
Ex. Change SP1H from 2.0×10-2 to1.0×10-2
Pushset key and the unit goes to program mode
measuremode
Program mode
1. Blinking digit can be changed. Push shift key to move changing digit.
2. Push down key to change the value from “2” to “1”
3. Push set key to register the value. The unit automatically move to the next parameter.
×10
DS- 10
SP1 SP2 SP3
SET SET
SP1 SP2 SP3
DS- 10
×10
×10
DS- 10
SP1 SP2 SP3
SET
DS- 10
SP3
SP2SP1
SET
×10
SET
SP3SP2SP1
DS- 10
SP1
SET
DS- 10
SP3SP2
×10 ×10
SP3
×10
SP1 SP2
SET
DS- 10
SP3SP1
×10
SP2
DS- 10
SET
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

Parameters
In program mode the following parameters are displayed one by one by pushing set key.
charactor parameter
SP1
upper threshold
SP1H
SP1
lower threshold
SP1L
SP2
upper threshold
SP2H
SP2
lower threshold
SP2L
SP3
upper threshold
SP3H
SP3
lower threshold
SP3L
digital filter
dF
SET
SP1 SP2 SP3
DS- 10
×10 ×10
SET
SP3SP2
SP1
DS- 10
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

RAM Error
Reset by power off
blink data
over input data range
“0000”
Blinking
Over scale
“uuuu”
Blinking
Under scale
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]
Dieses Handbuch passt für folgende Modelle
1