TERSUS BCPI7 Bedienungsanleitung

- 1 -
Installation &Operation Manual
I
Full Inverter Swimming Pool Heat Pump

- 2 -
BCPI7 BCPI10,BCPI13
BCPI17 BCPI21 BCPI30 BCPI30
Thank you very much for purchasing our product, please keep and read this manual
carefully before you install heat pump.
Thank you very much for purchasing our please keep and read this manual carefully
Packing List
No.
Name
Qty.
Remark
1
Installation & Operation Manual
1
2
Wire-controller
1
3
Wire controller box and sponge pad
(to be installed on the heat pump shell)
1
4
Drain-pipe (2 m)
1
5
Drain-pipe connector
1

- 3 -
Please keep installation manual properly, and read it carefully before using.
The unit must be installed by professional personnel according to the instructions in this
manual.
WARNING: if the unit is installed in locations that are at risk of lightning strikes, lightning
protection measures must be provided.
WARNING: The unit is not suitable for use in winter: all water must be drained from the unit
during overwinter or it could freeze inside the unit causing damage to the internal components.
Content
Accessories……………............................................................................4
Safety.........................................................................................................5
Heat pump working principle..................................................................6
Installation of the unit..............................................................................8
Installation of the pipeline.....................................................................12
Installation of optional accessories......................................................14
6
Rubber shock absorber
4
7
Heat Pump Unit
(The pipe connector has been installed on the
machine)
1

- 4 -
Installation and operation of electric devices......................................15
Operating Instructions... .......................................................................18
Wireless/Remote control................................................. ......................32
Adjusting and Initial operation ..............................................................42
Operation and maintenance...................................................................43
Fault analysis and elimination method.................................................45
Technical parameters.............................................................................46
After-sale service....................................................................................47

- 5 -
Each unit produced by our factory comes with the following accessories:
In order for the system to work the following parts are required
No.
Name
Qty.
use
1
Water pump
1
To circulate the pool water
2
Filter system
1
To clean the pool water which passes through
the heat pumps
3
Water pipes system
1
To connect the equipment and circulate the
water in the pool
NOTE
The types and quantity of the water pipes, valves, filter equipment, sterilizing equipment used for the
swimming pool heating/circulation pipe system, depend on the project design. We do not recommend to
install auxiliary electric heaters in the system.
No.
Name
Qty.
Use
1
Installation & Operation Manual
1 PC
User Guide to install the unit
2
Wire controller
1 PC
Used for the machine operation interface
3
Drain-pipe
1 PC
Used for draining the condensate water
4
Drain-pipe connector
1 PC
To connect the drain pipe to the heat pump
5
Shock absorb Rubber
4 PCS
To reduce vibration and noise
6
Heat pump unit
1 SET
For heating water
1. Accessories

- 6 -
●The installation should be done by the professional persons, to prevent leaking, electric shock or
fire.
● Confirm the ground connection, if the ground connection is not correctly done, it may cause electric
shock.
2. Safety
Range of application:
1.Power supply: 220V-240V/1N~50Hz.
2.Ambient temperature: -15°C〜43°C :
3.Working water temperature: Min. inlet water temperature 8°C,Max. outlet Water
Temperature 40°C. If the system is always used beyond the available water range,
please contact with manufacturer.

- 7 -
THE UNIT MUST BE EARTHED PROPERLY BEFORE USAGE OR THE
When installing the heat pump in a small room, make sure it is well ventilated.
● Don't put fingers or objects into the air inlet outlet as the rotating fan could cause serious injuries.
● If you smell anything burning, turn off the manual power switch immediately, stop operation and
contact the after-sale service department. Continued abnormal operation may cause electric shock
fire.
● When the unit needs to be removed or re-installed, please ensure that the work is carried out by
qualified professionals. If the installation is not correct, it may cause unit operation failure, electric
shock, fire, hurt, leaking, etc.
● Please ensure that any repairs carried out by qualified professionals: failure to make proper repairs
could cause unit operation failure, electric shock, fire, hurt, leaking, etc..
● Do no install the unit near flammable sources, as any leakages could cause a fire.
● Make sure the base on which the unit is installed is strong enough to support it.
● Make sure a leakage protection switch is installed to prevent electric shock or fire.

- 8 -
●When cleaning the unit, stop operation, switch off the power and disconnect the power..
3.1 Heat pump operation
Heat pumps use heat from the sun by collecting and absorbing energy from the outside air.
This energy is then compressed and transferred to the pool water. Your existing water pump
circulates the water through the heat pump, which is normally installed next to the pool
filtration system, and the water warms up. The heat pump timer can be set so that the pump
operates at the times you want: for example, during daylight hours from 9am to 5pm.
➢ The unit contains a fan that draws in outside air and directs it over the surface of the
EVAPORATOR (energy collector). The liquid refrigerant inside the EVAPORATOR coil
absorbs the heat from the outside air and becomes a gas.
➢ The warm gas inside the coil passes through the COMPRESSOR, which concentrates
and increases the heat to form a very hot gas, which then passes through the
CONDENSER (water heat exchanger). It is here that the heat exchange occurs as the
heat from the hot gas is transferred to the cool swimming pool water circulating through
the heat exchanger.
➢ The pool water becomes warmer and the hot gas returns to its liquid form as it flows
through the CONDENSER coil. The gas then passes through the Electronic Expansion Valve
3. Heat pump unit working principle

- 9 -
and the whole process begins again.
➢ Developments in heat pump technology mean that today heat pumps can efficiently
collect heat from the outside air even when the temperature is as low as 7-10°C. This
means that for tropical and subtropical climates the pool can be maintained between 26°C and 32°C.
3.2 Air source heat pump working principle
4 way valve
Water inlet
Water Outlet
Condenser
Gas-liquid
separator
Compressor
Filter
Expansion valve
Filter
Evaporator
Fan unit
Figure 1
Qc (Heat energy) = Qa (Compressor consumption) +Qb (Heat energy absorbed from ambient
environment)
4.1 Installation Guidelines
4. Installation of the unit

- 10 -
● Avoid installations in locations containing mineral oil.
● Avoid installation in locations where the air contains salt or other corrosive gases.
● Avoid installation in locations with serious power supply voltage fluctuation.
● Avoid installation in unstable places, such as a car or cabin.
● Avoid installation near flammable items.
● Avoid installation in locations with strong electromagnetic forces.
● Avoid installation in locations with harsh environmental conditions.
4.2 Installation check
● Check the model, number, name etc, to avoid incorrect installation.
● Make sure there is enough space for installation and maintenance.
● Install in a dry well-ventilated place and make sure there are no obstructions around the air inlet
and outlet.
● Make sure the supporting base is strong enough and prepared to that shocks can be avoided.
● The power supply and diameter of the cables used must be in accordance with the electrical
installation requirements.
● Electrical installation must comply with the relevant technical standards of electrical equipment,
and electrical insulation work must be done.
● The unit must be put horizontally for at least eight hours before running.
4.3 Installation space
Dieses Handbuch passt für folgende Modelle
5
Inhaltsverzeichnis
Beliebte Wärmepumpe Handbücher anderer Marken

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Bedienungsanleitung

Dimplex
Dimplex LI 16I-TUR Benutzerhandbuch

Carrier
Carrier WSHP Open v3 Kurzanleitung zur Einrichtung

TGM
TGM CTV14CN018A Bedienungsanleitung

Carrier
Carrier 38MGQ Series Bedienungsanleitung

Kokido
Kokido K2O K880BX/EU Fehlerbehebungshandbuch