Tesup ATLAS X Bedienungsanleitung

1
MADE IN EUROPE
ATLAS X
VERTICAL TURBINE
“WIND POWER NOW AT YOUR
DOORSTEP.”
USER
MANUAL
Revision Index 00
Revision Date: 08th Nov ’21
ENGLISH | EN
ATLAS X (MADE IN EUROPE)

2
PRODUCT OVERVIEW
ATLAS X (MADE IN EUROPE)
ATLAS X

3
INDEX
1. INDEX
ATLAS X (MADE IN EUROPE)
Sr. No. Description Page
no.
1Index 3
2General 5
2.1 General Instructions 5
2.1.1 Operating and Installing Conditions 5
2.2 Symbols Used 6
2.3 Warranty Details 6
2.4 Product Feedback 6
3Technical Description 7
3.1 Intended Use 7
3.2 Reasonably foreseeable misuse 7
3.3 System Components 8
3.4 Wind Turbine Components 9
4Parameter and Dimensional Details 10
4.1 Parameter Details 10
4.1.1 Power Curve 11
4.2 General Arrangement Drawing 12
5Controller 13
5.1 Technical Details 13
5.2 Wiring Diagram 14
5.3 Permissible Storage & Operation 15
6Safety Information 16
6.1 Modifications or changes by the user 16
6.2 Residual Risks 16
6.3 Personnel Requirements 16
6.4 Important Safety Instructions 17
7Pre-Use Preparation 18
7.1 Shipping Conditions 18
7.2 Prerequisites at the place of use 18
7.2.1 Permissible wind class, footprint, and minimum
clearances 18
7.2.2 Mounting Details 19
7.3 Unpacking the components 20
7.4 Assembling the wind turbine 20
7.5 Electrical Connections 23
8Regular Operation 24
8.1 Switching on the wind turbine system 24

4
INDEX
ATLAS X (MADE IN EUROPE)
Sr. No. Description Page
no.
8.2 Restart after emergency 24
9Shutting down the System 25
9.1 Emergency Shutdown 25
9.2 Temporary shut-down 25
9.3 Prolonged shut-down 25
10 Maintenance 26
10.1 Safety precautions during maintenance work 26
10.2 Inspection and maintenance schedule 26
10.3 Maintenance & cleaning by the user 27
11 Removal from service & disposal 28
11.1 Final decommissioning wind turbine 28
11.2 Disposal of the wind turbine system & components 28
12 Declaration 29
13 Appendix 30
14 Notes 31
1. INDEX

5
2.1 GENERAL INSTRUCTIONS
2. GENERAL
• Before you begin installing, read this entire owner’s manual. Identify and
note your model wind turbine where it appears in this manual. Following
the instruction and recommendations in this manual will help assure safe
and enjoyable use of your new renewable energy system. Please take the
time to read through this manual prior to assembly.
• Place this instruction manual in a safe place for reference.
• Wait until a calm day to install or perform maintenance on your Turbine
with activation of brake.
• Listen to your Turbine, if you hear any mechanical noise, maintenance
may be required, please contact your Turbine dealer.
• After installation re-adjust and tighten the screws and bolts.
• Adhere to proper grounding techniques as established by the National
Electrical Code.
• Your Wind Turbine must be installed in accordance with this manual
and local and national building code. Incorrect installation may void
your warranty.
• Wind Turbine blades spin at a potentially dangerous speed, this must be
respected. Never approach a Turbine in motion.
• Note wire size prior to wiring. Any under sizing of wire can be poten-
tially dangerous.
• Check the manual brake periodically.
• Check the battery health periodically. The low battery voltage and im-
proper connection can cause over-spin issues.
2.1.1 OPERATING & INSTALLING CONDITIONS
• Please make sure that:
• The wind turbine system has been erected correctly by a suitably
trained person.
• All operating personnel have read and fully understood this translation
of the original instructions
• The wind turbine system is properly maintained and repaired.
ATLAS X (MADE IN EUROPE)

6
2.2 SYMBOLS USED
2. GENERAL
2.3 WARRANTY DETAILS
• The “General Terms of Sale and Delivery” of the manufacturer or his
authorized representative apply.
ATLAS X (MADE IN EUROPE)
In this Manual:
IMPORTANT: Please take a note.
DANGER: Immediate danger can cause serious injury.
WARNING: Potential Danger can cause Serious injury.
CAUTION: Potential Danger can cause moderate injury.
NOTE: Useful Tips
OTHER SIGNS USED:
GENERAL WARNING.
HIGH VOLTAGE
MAY START WITHOUT WARNING.
ENVIORNMENTAL HAZARD
2.4 PRODUCT FEEDBACK
• Please notify the manufacturer or his authorized representative about any
of the following:
• Accidents
• Potential safety hazards associated with the wind turbine system
• Ambiguities in this translation of the original instructions
• Description of the wind turbine system
SAFETY SYMBOLS

7
3.1 INTENDED USE
3. TECHNICAL DESCRIPTION
• The wind turbine system may only be used as a “small wind turbine sys-
tem” (SWTS) to generate power in accordance with EN 61400-2.
• The wind turbine system may only be operated in accordance with the rat-
ings and in the approved wind class (refer to the technical data).
• Observance of the original instructions and compliance with the mainte-
nance and repair instructions are essential preconditions of use for the in-
tended purpose.
3.2 REASONABLY FORSEEABLE MISUSE
• All forms of use which deviate from or exceed the limits of use described
above are contrary to the intended purpose. The manufacturer is not liable
for any damage resulting from such use.
• No liability will be accepted by the manufacturer if the equipment has been
altered as well as in the event of improper assembly, installation, start-up,
operation, maintenance, or repair.
• Only original parts supplied by the manufacturer are approved as spare
parts or accessories. Any spare parts or accessories not supplied by the
manufacturer have not been tested for operation and could be detrimental
to reliability. No liability will be accepted by the manufacturer for any dam-
ages which result from the use of non-approved spare parts or accesso-
ries.
• Reasonably foreseeable misuse includes:
• Operation outside the manufacturer’s specification.
• All modifications or changes to the wind turbine system without the
manufacturer’s written approval!
• Use of parts other than ATLAS X original parts.
• Operation in non-approved SWTS classes.
• Operation in strong winds or hurricanes.
ATLAS X (MADE IN EUROPE)

8
3.3 SYSTEM COMPONENTS
3. TECHNICAL DESCRIPTION
NOTE: Several Batteries can be connected in Parallel
Or series depending upon the system voltage.
ATLAS X (MADE IN EUROPE)
ATLAS X CHARGE CONTROLLER
BATTERY INVERTER

9
3.4 WIND TURBINE COMPONENTS
3. TECHNICAL DESCRIPTION
ATLAS X (MADE IN EUROPE)
Sr. No. Description Quantity
1Turbine Blades 12
2Bottom Flange 1
3Mounting base 1
4Wing Support 24
5Mounting Shaft 1
6Top Flange 1
1
2
3
4
5
6
PART LIST TABLE

10
4.1 PARAMETER & DIMENSIONAL DETAILS
4. PARAMETER & DIMENSIONS
ATLAS X (MADE IN EUROPE)
SPECIFICATIONS
DESIGNATION 12V to 48V
GENERATOR
TYPE 1KW vertical axis wind permanent magnet gener-
ator
WEIGHT 10kg (22lbs)
MAX. POWER 1kW
OPERATING CIRCUIT VOLT-
AGE
0-100V
CURRENT 3-Phase
START OF CHARGING 3m/s
BASE PLATE MATERIAL Sheetmetal
DIRECTION OF ROTATION Clockwise
TEST STANDARDS
EN 61000-6-1 (electromagnetic compatibility – im-
munity)
EN 61000-6-3 (electromagnetic compatibility –
emissions)
ROTOR BLADES
MATERIAL Composites
HUB FLANGE Aluminum
DIAMETER 525 mm (1.72 Feet)
WEIGHT PER ROTOR
BLADES
100 g (0.22 lbs)
DIRECTION OF ROTATION Counter-Clockwise
STARTING WIND SPEED 3 m/s
NO. OF BLADES 12
MAX RPM 650
MAX SPEED 50m/s
NOISE 30 dB
WARNING: If a hurricane scale III (50–58 m/s) or
above occurs, please cover wind turbine blades.
PARAMETERS