CL-B101D40PS Manual (d0096) Page 1
CL-B101D40PS
Smart 101 segment, 4 digit LED Tricolor or Mono-color
digital bargraph controller with Programmable Scale
Factor input signal scaling and four fully programmable
set points in a switchboard style case for
monitoring, measurement, and control applications.
0.56” LEDs
•
External transmitters or signal conditioners can be eliminated by
direct connection of the sensor output to more than
40 Plug-in Input Signal Conditioners that include:
– AC/DC Current – Pressure – Resistance
– AC/DC Voltage – Process – Temperature
– Load Cell – Prototype – 4 to 20 mA
•
Optional isolated 16 bit analog output. User or factory scalable to 4
to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span
from ± one count to the full scale range of – 1999 to 9999 (12000
counts).
•
A Programmable Tricolor (Red-Green-Orange) or mono color (red or
green), 101 segment high brightness bargraph.
•
Red 4-digit LED display with a range of -1999 to 9999
(12000 counts). Optional green digital display.
•
Front panel LED annunciators provide indication of setpoint status.
•
Two 9 Amp Form C, and two 4 Amp Form A or 4 x 4 Amp Form A
relays available
.
•
Auto-sensing AC/DC power supply. For voltages between
85-265 V AC / 95-300 V DC (PS1) or 18-48 V AC / 10-72 V DC
(PS2).
•
24 V DC excitation is available to power external 4/20mA
transmitters and 5 or 10 V DC excitation is available for
resistance bridge type sensors.
•
Provision to connect an external programming lockout switch.
•
Provision for external DIM switch to reduce the brightest
display setting by 50%.
•
Automatic intelligent averaging, smooths noisy signals while
providing a fast display response to real level changes.
General Features
Specifications
• Thebargraphcandisplay,full
scale, any desired portion of
the digital reading.
• Setpoint1hasdelay-on-make
and delay-on-break plus
a special “pump on pump
off” mode that creates a
Hysteresis Band between SP1
and SP2.
Software Features
•
Four programmable setpoints
with adjustable Hysteresis.
•
Bargraph center zero function.
• Relayactivationcanbeselect-
ed to occur above (hi) or below
(Lo) each setpoint.
• Digitaldisplayblanking.
• Decimalpointsetting.
• Four-levelbrightnesscontrol
LEOPARD
FAMILY
Input Specs:������������������ Depends on Input signal conditioner
A/D Converter:�������������� 14 bit single slope
Accuracy:���������������������� ±(0�05% of reading + 2 counts)
Temp. Coeff�:����������������� 100 ppm/°C (Typical)
Warm up time:��������������� 2 minutes
Conversion Rate:���������� 10 conversions per second (Typical)
Digital Display:��������������
4 digit 0.56" LED red (std), green (optn)
Range
–1999 to 9999 counts�
Bargraph Display:���������
101 segment 235º circular red (standard),
Green (optional) or tricolor (optional) LED�
Polarity:������������������������� Assumed positive� Displays – negative
Decimal Selection:�������� Front panel button selectable, X•X•X•X•
Positive Overrange:������ Bargraph and top segments of digital display
flash�
Negative Overrange:���� First segment of bargraph and bottom seg-
ments of digital display flash�
Relay Output:���������������� Two 9 Amp Form C relays, two 4 Amp Form
A relays or
4 x 4 Amp Form A relays
Analog Output:������������� Isolated 16 bit user scalable mA or V
OIC (mA out) ��������������
4-20 mA @ 0 to 500Ω max loop resistance
OIV (volts out) �������������� 0-10 V DC @ 500 ٠or higher resistance
Power Supply:��������������� AC/DC Auto sensing wide range supply
PS1 (std)��������������������
85-265 VAC / 95-300 VDC, 50-400Hz 4.2W
PS2�����������������������������
18-48 VAC / 10-72 VDC, 50-400Hz 4�2W
Operating Temp�: ���������� 0 to 50°C
Storage Temp:��������������� –20°C to 70°C
Relative Humidity:�������� 95% (non condensing)
Case Dimensions:��������
Bezel (4.48"x4.48") 113.8x113.8mm
Depth behind bezel (4.23") 107.46 mm
Plus (0�48”) 12�24 mm for connectors
Weight:��������������������������� 16 oz�, 1lb 4 oz when packed
Table of Contents
Bargraph Center Point Display Mode Selection .. 7
Bargraph Color Programming Mode ...... 10
Case Dimensions....................... 8
Component Layout .................... 12
Connector Pinouts ..................11-12
Controls and Indicators ................. 2
Decimal Point and Brightness Selection .... 6
Digital Span Selection for Bargraph Display . 6
Programming Conventions ............... 2
Setpoint Setting & Relay Conf. Mode ....9-10
Software Features ...................... 1
Software Logic Tree .................... 3
Specifications ......................... 1
Successive Digital Rescaling ....................5
Two Point Analog Range Setting & Calibration ... 8
Digital Span Selection for Analog Range Output . 7
Functional Diagram .................... 11
General Features ....................... 1
I-Series Input Signal Conditioning Modules ..13-15
Input Module Calibration Procedures ..... 17
Input Module Component Glossary ....... 16
Ordering Information ................... 19
Pin Descriptions ...................... 11