Introduction
Specifications
Control Panel / Remote
Unit Diagrams
Unit Setup & Operation
Maintaining the Unit
Safety info / Warnings
Warranty Information


3
Introduction
Welcome to a more comfortable, efcient way of heating your living spaces during cold weather!
ThermaWave Polar is the most complete and advanced space heating system on the market. It heats using a
cutting-edge PTC (Positive Thermal Coefcient) element that heats the air efciently without drying it out. It
puries your air with PCO technology that features a high power germicidal UVC bulb. This bulb, in conjunction
with a catalyst, creates a purifying plasma that reduces mold, bacteria, and viruses (even on surfaces) so the
months spent with doors and windows closed no longer means months spent in a stuffy indoor environment.
Polar is designed to provide years of trouble-free service when used and maintained according to this Owner’s
Manual. The pages of this manual will guide you through proper operation, cleaning the lter, and replacing the
PCO Cell as necessary.
Thank you for purchasing ThermaWave Polar by GreenTech Environmental.
Records
Purchase Date: __________________________________________________________________________
Model Number:__________________________________________________________________________
Serial Number: __________________________________________________________________________
Distributor Name: ________________________________________________________________________
Distributor Phone:________________________________________________________________________
Features
PTC Infrared Heating Element
PCO Air Purication Technology
LCD Display
Unit Control Panel
Control Remote
Quiet Mode
Overheat Safety Shut Off
Tip-Over Safety Shut Off
Benets
Clean, Economical, and Safe Heating
Even Distribution of Heat from Floor to Ceiling
Does not Burn or Dry Out Air
Low Operating & Maintenance Cost
Efcient PCO Purication for Pure, Clean, Heated Air

Copyright © 2010 GreenTech Environmental; All Rights Reserved
4
CAUTION: Attempting to service the unit beyond
cleaning the lter or changing the PCO Cell
creates danger of electric shock.
WARNING: Keep the unit away from fabric or
other ammable material. Give the unit 3 ft of
space to the front and at least 1 ft of space to
the sides and rear.
WARNING: Do not cover the Hot Air Outlet
Specications
Voltage: .....................................................................120V ~60Hz
Power: ...................................................................up to 1500 watts
Heat Output: ....................................................................5200BTU
Remote Battery: .................................................................. CR2025
Temperature Control Range: .........................................60 - 90 Degrees Fahrenheit
Heating Element: ............................. Infrared Positive Thermal Coefcient (PTC) Element
Air Filter: ...............................................................Lifetime Washable
Air Purier: ............................................. Photo Catalytic Oxidation (PCO) Cell
Display: ...........................................................................LCD
Coverage: ...................................................................Up to 1000 ft2
Dimensions: ................................................ 13.25” x 15.5” x 17.25” (WxDxH)
Weight: ..........................................................................26.6 lbs
Certications: ............................................... ETL Canada & US by Intertek
Warranty: ........................................................... 3 Year Factory Limited
Warnings
CAUTION: Disconnect the power cord before
cleaning the lter or changing the PCO Cell.

5
PURIFIER
QUIET
TIMER
HEATER
POWER
COOLER WARMER PURIFIER QUIETTIMER
Control Panel & Remote Control Diagrams

Copyright © 2010 GreenTech Environmental; All Rights Reserved
6
Unit Front Diagram
Unit Rear Diagram

7
Setting Up the Unit
1. Unpack the unit by cutting open taped areas. Fold back box aps and gently turn entire box upside down.
Lift box off of styrofoam packed contents. Remove styrofoam, turn upright. We recommend keeping
packing materials for future transport or storage of unit.
2. Find a level and unobstructed location to place heater away from cold walls (outside walls).
3. Plug the POWER CORD into a grounded outlet (120V, 15A or higher).
4. Activate the REMOTE by removing the plastic shipping guard from the battery compartment.
Operating The Unit
Turning the Unit On/Off
• Turn the unit on by pressing the “I” on the POWER TOGGLE (Unit Rear).
• Turn the unit off by pressing the “O” on the POWER TOGGLE (Unit Rear).
• Always unplug the unit when not in use.
Heater Mode
• Press the HEATER CONTROL button to activate the Heater Mode. (This will also automatically activate
Purier Mode. To toggle Purier Mode on or off, press the PURIFIER CONTROL button.) Set the
desired temperature using the TEMPERATURE CONTROL buttons. You may select a temperature from
60 to 90 degrees Fahrenheit.
Purier Mode
• Toggle the Purier Mode on or off at any time that the unit is turned on by pressing the PURIFIER
CONTROL button.
Timer Function
• Set the TIMER FUNCTION by pressing the TIMER CONTROL button to activate it.
• Press the TIMER CONTROL button once for each additional hour desired (1 - 12 hours).
• If you press the TIMER CONTROL button again once the TIMER INDICATOR on the LCD DISPLAY
reads “12h” the TIMER FUNCTION will be deactivated.
• If the Heater & Purier Modes are active and you set the timer, it will turn both modes off after the
designated time has elapsed.
• If either the Heater or Purier Modes are independently active and you set the timer, it will turn the active
mode off after the designated time has elapsed.
• If neither the Heater or Purier Modes are active (nothing is active) and you set the timer, it will turn ON
both the Heater and Purier Modes after the designated time has elapsed.

Copyright © 2010 GreenTech Environmental; All Rights Reserved
8
Quiet Function
• If you feel the unit is too loud for your environment, such as when you are sleeping, press the QUIET
MODE CONTROL button. The unit continues to heat and purify according to active modes, but the fan runs
on the most silent speed.
Maintaining The Unit
Filling the Humidier
1. Open the HUMIDIFIER TANK CHAMBER (Open the door on the right side of the unit).
2. Slide the HUMIDIFIER TRAY out and remove the HUMIDIFIER WATER BOTTLE.
3. Fill the HUMIDIFIER WATER BOTTLE with tap water and replace in HUMIDIFIER TRAY. Once the
water has lled the tray, rell the HUMIDIFIER WATER BOTTLE a second time. replace the HUMIDIFIER
WATER BOTTLE in the HUMIDIFIER TRAY.
4. Slide the HUMIDIFIER TRAY back into the HUMIDIFIER TANK CHAMBER
5. Close the HUMIDIFIER TANK CHAMBER
Whenever water is present in the HUMIDIFIER TRAY, diverted warm air will wick the moisture and the result
will be a more comfortable heat. If the HUMIDIFIER TRAY is empty, it will not damage the unit but you will
not enjoy the benets of the humidication feature. Check your HUMIDIFIER TRAY daily using the window
in the HUMIDIFIER TANK CHAMBER DOOR.
Cleaning the Filter
The lter should be cleaned every 30 days or more often if you nd that the lter is collecting visible particulate.
1. Unplug the POWER CORD from the outlet.
2. Remove the FILTER ASSEMBLY SCREW using a screwdriver. Place the screw aside where you will not
misplace it.
3. Allow the FILTER ASSEMBLY to lean away from the rear of the unit until it is free to be removed.
4. Remove the FILTER from the FILTER ASSEMBLY by using a at blade screwdriver to release the four tabs
of the FILTER COVER and then carefully lifting the FILTER from the FILTER ASSEMBLY.
5. Use a vacuum cleaner to remove built up particulate from the FILTER. Optionally, you can also clean the
FILTER using warm soapy water. If you opt to using water, ensure that the FILTER dries completely before
continuing.
6. Carefully replace the FILTER in the FILTER ASSEMBLY. Replace the FILTER COVER onto FILTER
ASSEMBLY and ensure all 4 tabs are in place.
7. Set the tabs of the FILTER ASSEMBLY in their place on the rear of the unit and pivot upwards until it is
properly seated.
8. Replace the FILTER ASSEMBLY SCREW using a screwdriver. Tighten until snug.
9. Plug the POWER CORD back into the outlet.

9
Cleaning the Unit
1. Unplug the POWER CORD from the outlet.
2. Carefully wipe the exterior of the unit with a soft, damp (not wet) cloth and dry thoroughly with a soft, dry
cloth. Do not use harsh or abrasive cleaners as these may damage the aesthetic nish of the unit.
3. Remove particulate that may have gathered in the HOT AIR OUTLET using a vacuum with a brush
attachment.
Replacing the PCO Cell
After some time the “Replace UV BULB” indicator may appear on your LCD SCREEN. This indicates that
you need to replace your PCO Cell. You may purchase a replacement PCO Cell through your GreenTech
Environmental Authorized Distributor. If your distributor is not available, please visit www.GreenTechEnv.com
to contact us regarding ordering a PCO Cell directly.
1. Remove the FILTER ASSEMBLY by following steps 1 through 3 of “Cleaning the Filter”.
2. Unplug the old PCO Cell by disengaging the electrical adapter in the lower right hand region of the rear of
the unit.
3. Unscrew the Thumbscrews and slide the old PCO Cell straight out of the rear of the unit.
4. Slide the new PCO Cell straight into its place in the rear of the unit and replace Thumbscrews.
5. Connect the new PCO Cell by plugging in the electrical adapter to it’s socket.
6. Replace the FILTER ASSEMBLY by following steps 7 through 9 of “Cleaning the Filter”.
Electrical
Adapter
PCO
Cell
Plastic Coated
Thumbscrews

Copyright © 2010 GreenTech Environmental; All Rights Reserved
10
Safety Info & Warnings
1. Do not operate the heater if any cord or part of the machine is damaged or has malfunctioned.
Return heater for examination and repair if damage has occured.
2. Do not plug heater into anything other than a 3-prong 110V 15amp or higher grounded circuit receptacle.
3. Do not use an extension cord to power this heater.
4. Do not block the front grill or rear lter of the heater. Be sure that there is adequate space around the heater
for air ow.
5. Keep heater away from areas which may have standing water. The heater is not made for use in bathrooms,
laundry areas or areas with similar attributes.
6. Do not insert any foreign objects into the vent as this may cause an electric shock or damage the heater itself.
7. Do not change the heater’s wiring or design as it will void the warranty and could cause injury.
8. Always unplug heater when not in use.
9. Turn heater off before removing plug from outlet.
10. Do not place cord under any kind of covering such as carpet, rugs or similar articles. Place cord away from
high trafc areas to keep from injuring a person or causing damage to the cord or heater.
11. Heater is intended for indoor use only, do not use outdoors.
12. The lter must be cleaned regularly to avoid clogging and possible malfunction of the heater. If the heater
is used in high-trafc areas the lter must be cleaned more often.
13. Air dry the lter, do not use any other method to expedite the process as it could damage the lter.