Thermo Solar ECO2 160 Technisches Dokument



TABLE OF CONTENTS
INSTRUCTIONS FOR THE MOUNTING
OF THE SUPPORT BASE ON TILT ROOF Page 4-5
DESCRIPTION OF THE PLUMBING ASSEMBLY BETWEEN THE WATER TANK
AND COLLECTOR ON TILT ROOF Page 6-7
INSTRUCTIONS FOR THE MOUNTING
OF THE SUPPORT BASE ON FLAT ROOF Page 8-9
DESCRIPTION OF THE PLUMBING ASSEMBLY BETWEEN THE WATER TANK
AND COLLECTOR ON FLAT ROOF Page 10-11
INSTRUCTIONS FOR THE MOUNTING
OF THE SOLAR SYSTEM ON FLAT ROOF Page 12-13
TECHNICAL CHARACTERISTICS – DIMENSIONS –
WEIGHTS OF SOLAR SYSTEMS Page 14
TYPES OF SOLAR SYSTEMS / PROPORTION OF ANTIFREEZE LIQUID – WATER Page 14
TECHNICAL CHARACTERISTICS OF THE WATER TANK Page 15
TECHNICAL CHARACTERISTICS OF THE COLLECTOR Page 15
ELECTRICAL CONNECTION DIAGRAM
OF AUXILIARY HEATING RESISTANCE (DOUBLE ENERGY) Page 16
ELECTRICAL CONNECTION DIAGRAM OF AUXILIARY HEATING RESISTANCE
AND COPPER TUBE COIL FOR EXTERNAL THERMAL SOURCE (TRIPLE ENERGY)
ORIENTATION OF SOLAR SYSTEM Page 17
INSTALLATION OF 6 SOLAR SYSTEMS ON LINE
DIMENSIONS OF SOLAR SYSTEMS Page 18
INSTALLATION OF SOLAR COLLECTORS ON LINE (20sq.m.) Page 19
TECHNICAL INSTALLATION
MANUAL FOR THE
SOLAR SYSTEM
TABLE OF CONTENTS
INSTRUCTIONS FOR THE MOUNTING
OF THE SUPPORT BASE ON TILT ROOF Page 4-5
DESCRIPTION OF THE PLUMBING ASSEMBLY BETWEEN THE WATER TANK
AND COLLECTOR ON TILT ROOF Page 6-7
INSTRUCTIONS FOR THE MOUNTING
OF THE SUPPORT BASE ON FLAT ROOF Page 8-9
DESCRIPTION OF THE PLUMBING ASSEMBLY BETWEEN THE WATER TANK
AND COLLECTOR ON FLAT ROOF Page 10-11
INSTRUCTIONS FOR THE MOUNTING
OF THE SOLAR SYSTEM ON FLAT ROOF Page 12-13
TECHNICAL CHARACTERISTICS – DIMENSIONS –
WEIGHTS OF SOLAR SYSTEMS Page 14
TYPES OF SOLAR SYSTEMS / PROPORTION OF ANTIFREEZE LIQUID – WATER Page 14
TECHNICAL CHARACTERISTICS OF THE WATER TANK Page 15
TECHNICAL CHARACTERISTICS OF THE COLLECTOR Page 15
ELECTRICAL CONNECTION DIAGRAM
OF AUXILIARY HEATING RESISTANCE (DOUBLE ENERGY) Page 16
ELECTRICAL CONNECTION DIAGRAM OF AUXILIARY HEATING RESISTANCE
AND COPPER TUBE COIL FOR EXTERNAL THERMAL SOURCE (TRIPLE ENERGY)
ORIENTATION OF SOLAR SYSTEM Page 17
INSTALLATION OF 6 SOLAR SYSTEMS ON LINE
DIMENSIONS OF SOLAR SYSTEMS Page 18
INSTALLATION OF SOLAR COLLECTORS ON LINE (20sq.m.) Page 19
TECHNICAL INSTALLATION
MANUAL FOR THE
SOLAR SYSTEM
18
19
20
21
22-23
16-17
Page
PageCOLLECTOR’S DATA SHEET
TRANSPORTATION AND HANDLING

04
We first check that the height of the pitch roof from the
highest top until the lower part of the solar system is at
least 3800mm-minimum.
We begin from the lower part of the support base by
raising the tiles and positioning the stainless steel
straps (F) between and under the convex of tiles with a
distance between them of a min. 900mm and max.
1080mm (D1-D2).
We screw the stainless steel straps to the oblong wood
or flooring as at (photo 1) and we leave the one side
out of the tiles, at least 200mm in the same distance
and length between them.
We reposition again the tiles as they were and we
screw the external side of the stainless steel straps (F)
on the vertical long bracket supports (A-A) of the
support base (photo 2) with the plastic hatch on the
min 900mm -
3.800 mm minimum
A
F
A
A
B
DÅ
photo 1
photo 2
photo 3
INSTRUCTIONS FOR THE MOUNTING OF THE

05
top side (photo 3)
We repeat the same process on the upper side of the
support base with the difference that:
ATTENTION: We first screw the stainless steel
straps (F) on the top of the vertical long bracket
supports (A-A) as at (photo 6) after we have raised
the tiles, then we screw the stainless steel straps (F) to
the oblong wood or flooring as at (photo 1) and we
reposition again the tiles as they were before.
When we have finished with the vertical long bracket
supports (A-A) we position and screw at their lower
part the horizontal support angle (C) of collector as at
(photo 4) and at their upper part the horizontal
support angle (B) of water tank-collector (photo 5 ).
SUPPORT BASE ON TILT ROOF
max 1080mm
C
B
A
A
C
DÇ
photo 4
photo 5
photo 6

01
02
03
04
05
06
07
09
10
11
12
13
14
15
13
17
24
14
13 18 13 15
16 13 15
02
06
DESCRIPTION OF THE PLUMBING ASSEMBLY BETWEEN THE

08
19
22 23
12
13
20
13 13
18
16 13
04
16
07
01 Solar water tank
02 Water tank’s support angle
03Solar Collector(s)
04 Collector’s support angle
05 Hot water supply (outlet)
06 Brass Tee ó"
07 Pressure relief valve of hot water supply ó"
08 Pressure relief valve female ó" (closed circuit)
09 Cold water supply (inlet)
10 Cold water expansion control valve with non-return and
pressure relief valve (7 bars)
11 Cold water outlet from water tank to collector
(closed circuit)
12 Brass angle " Male-Female
13 Permanite washer (fibre)
14 Long stainless steel tube with brass raccor (closed circuit)
15 Brass nut male "
16 Brass nut female "
17 Brass screw plug Male "
18 Brass angle " Male-Female
19 Inlet of hot water from collector to water tank
(closed circuit)
20 Short stainless steel tube with brass raccor (closed circuit)
21 Brass interconnector "(only for the connection
between 2 or 3 collectors)
22 Brass reducing hexagon bush "- ó"
23 Spherical switch with special nozzle for plastic pipe,
for the filling of the closed circuit with thermal fluid.
24 Protection side cover of aluminium for the flow tube
WATER TANK AND COLLECTOR ON TILT ROOF
34
/
34
/
34
/
34
/
34
/
34
/
34
/
34
/
34
/

08
We place the metallic small plate (F) at the
backside of the long bracket support (A) at the
lower part as at (photo 3) and screw it tight. We
screw well the metallic corners (G) at the side parts
of the vertical shorter bracket support (D) as at
(photo 2) using the (oval) longer hole.
We insert the cutting bevel part of the vertical
shorter bracket support (D) in the slot of the back
side of the long bracket support (A) as at (
photo 1
).
We assemble the "X" diagonal braces (E) with
screw and back nut at the middle hole and then we
adjust them at the back side of the vertical shorter
bracket support (D) with screw and back nut as at
(photo 5).
INSTRUCTIONS FOR THE MOUNTING OF
photo 1
photo 2
photo 3
A
D
D
GG
B
E
D
A
A
F

09
We place the horizontal support angle (B) of the
water tank-collector as at (photo 4), and screw it
on the long bracket supports (A) being careful that
the notch and the screw are the middle ones as at
(photo 4). We apply the same procedure for the
lower horizontal support angle (C) of collector as at
(photo 6).
We have to take care that the solar support base
has the correct orientation (see page 17) and when
we have installed the collector/s and the water tank
on it, we drill the holes at the flooring with twist drill
of 10mm and we insert the plastic sockets and
long screws with washers as at (photo 2) and
(photo 3)
THE SUPPORT BASE ON FLAT ROOF
photo 4
photo 5
photo 6
D
A
C
A
B
E
F
C

10
DESCRIPTION OF THE PLUMBING ASSEMBLY BETWEEN
01
02
03
04
05
06
07
09
10
12 13 14
15
13
17
24
18
14
13
13 15
25
13
16 15
11
Dieses Handbuch passt für folgende Modelle
3