Timberline TL1002F-S Benutzerhandbuch

2
2
BEAVERTON, OR 97005
NIEDO GROUP, INC.
NA
B
1
-02
SHEET
DO NOT SCALE DRAWING
REV
DWG. NO.
SCALE:
1
3
3
SIZE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
UNLESS OTHERWISE SPECIFIED
TOLERANCES
MATERIAL:
DIMENSIONS ARE IN MILLIMETERS
FINISH:
5465 SW WESTERN AVE.
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
SET UP INSTRUCTIONS
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
1
TL1002F-S
NOTE: UNLESS OTHERWISE SPECIFIED
SET-UP MANUAL
10 Ft. Timberline Modular Display
SETUP TIME PER 10FT. SECTION IS 2-3 HOURS WITH 2 PERSONS.1.

1
DIMENSIONS ARE IN MILLIMETERS
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
3
3
2
2
FINISH:
BEAVERTON, OR 97005
NIEDO GROUP, INC.
-01
B
5465 SW WESTERN AVE.
NA 1
SHEET
DO NOT SCALE DRAWING
REV
DWG. NO.
1
MATERIAL:
TOLERANCES
SCALE:
SIZE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
UNLESS OTHERWISE SPECIFIED
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
SET UP INSTRUCTIONS
10 FT. TIMBERLINE MODULAR DISPLAY
TL1002F-S
(1) MOLDED PLASTIC WHEELED CASE
(1) CASE WILL CONTAIN DYE-SUB FABRIC PANEL
FEET
SHELF
WAVE TOP
HEADER
LAMP
TABLE
GRAPHIC
SUPPORT POST

SET UP ASSEMBLY DIAGRAM
10 FT. TIMBERLINE MODULAR DISPLAY
TL1002F-S
ITEM NO. DESCRIPTION QTY.
1 TIMBERLINE POST 2
2 TIMBERLINE FOOT 2
3 TOP SUPPORT POST 2
4 TIMBERLINE TOP 1
5 GRAPHIC HEADER 1
6 TIMBERLINE OVERHEAD LAMP 2
7 15-3/4" HORIZONTAL BAR END PC. 4
8 TIMBERLINE MOUNTED SHELF ASSEMBLY 3
9 TIMBERLINE ACCESSORY TABLE 1
10 GRAPHIC HEADER MOUNTING BRACKET 2
11 40 INCH FRAME EXTRUSION W/INSERT 2
12
40 INCH FRAME EXTRUSION WITHOUT INSERT
2
13 TIMBERLINE FOOT ATTACHMENT SCREWS 8
1
DIMENSIONS ARE IN MILLIMETERS
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
3
3
2
2
-01
FINISH:
BEAVERTON, OR 97005
NIEDO GROUP, INC.
5465 SW WESTERN AVE.
NA
B
1
SHEET
DO NOT SCALE DRAWING
REV
DWG. NO.
1
MATERIAL:
TOLERANCES
SCALE:
SIZE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
UNLESS OTHERWISE SPECIFIED
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
SET UP INSTRUCTIONS
13
3
1
1
1
1
4
2
2
5
6
7
7
8
9
10
11
11
12
12
3

ADJUSTMENT IS INSIDE AND AWAY FROM THE FRONT OF THE DISPLAY TO
STEP 5
- REFER TO ASSEMBLY DIAGRAM
AND BILL OF MATERIALS, PAGE 3
ASSEMBLE FRAME HORIZONTAL BARS #11 & #12, AND END BARS #7
TO THE MAIN POSTS #1
ASSEMBLE BARS TO POSTS BY INSERTING THE END OF THE LOCKING
MECHANISM FULLY INTO POST CHANNEL THEN TURNING THE SOCKET
HEAD ADJUSTMENT CLOCKWISE TO LOCK THE HORIZONTAL BAR
IN PLACE. THIS PROCESS IS USED FOR ASSEMBLING TOP AND BOTTOM
BARS ON THE FRAME. DISASSEMBLE BY TURNING THE ADJUSTMENT
COUNTERCLOCKWISE TO DISENGAGE. BE CERTAIN THAT THE INTERLOCK
AVOID BEING VISIBLE.
REMOVE SCREW FROM THE 40 INCH
.
BACKSIDE OF FRAME ONLY, AS SHOWN ABOVE
THAT HARDWARE IS INSERTED AND VISIBLE FROM
REMAINING 40 INCH HORIZONTAL BARS. BE CERTAIN
WITH ALLEN WRENCH PROVIDED. REPEAT FOR
(ITEM #12), REPLACE SCREW AND TIGHTEN
SLIDE INTO 2ND FRAME HORIZONTAL BAR
FRAME HORIZONTAL BAR W/INSERT (ITEM #11)
STEP 3
STEP 6
ATTACH HEADER INTO
PREVIOUSLY INSTALLED
HEADER BRACKETS. SIMPLY
SLIDE IN AND FINGER
TIGHTEN THUMB SCREWS.
(GRAPHIC HEADER ATTACHMENT)
STUDS INTO THE FRONT POST
STEP 2
REMOVE SCREW FROM LOWER POST
INSERT, SLIDE UPPER POST OVER
LOWER POST, INSERT SCREW AND
TIGHTEN. REPEAT WITH ALL POSTS.
BE CERTAIN THAT HARDWARE IS
INSERTED AND VISIBLE FROM BACKSIDE
OF FRAME ONLY, AS SHOWN ABOVE.
AT THIS POINT, IF INSTALLING
OPTIONAL ACCESSORY TABLES
AND / OR SHELVES, FIRST SLIDE
THE TABLE CLAMP MOUNTING
CHANNEL AS SHOWN. STEP 3
STEP 2 STEP 4 & 6
STEP 1
STEP 5
4
4
TOLERANCES
MATERIAL:
1
FINISH:
BEAVERTON, OR 97005
3
B
2
NA
-01
SHEET
UNLESS OTHERWISE SPECIFIED
5
5
DO NOT SCALE DRAWING
REV
DWG. NO.
SCALE:
SIZE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
NIEDO GROUP, INC.
3
2
DIMENSIONS ARE IN MILLIMETERS
1
5465 SW WESTERN AVE.
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
SET UP INSTRUCTIONS
A A
B B
C C
D D
8
8
7
7
6
6
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
1
TIGHTEN
PROVIDED, REPEAT WITH ALL
WITH 4 SCREWS (ITEM #13)
REMAINING FEET, ITEMS #2
BRACKET (ITEM #10) INTO
AND ALLEN WRENCH
UPPER GROOVE OF TOP
10 FT. TIMBERLINE MODULAR DISPLAY
STRUCTURAL ASSEMBLY SEQUENCE
TL1002F-S
STEP 1
FRAME HORIZONTAL BAR.
INSTALL TIMBERLINE FEET
SLIDE GRAPHIC HEADER
STEP 4
FOR ITEM #s
PLEASE REFER TO
ASSEMBLY DIAGRAM

HORIZONTAL SUPPORT BAR THEN CONNECT THE
SLIDE GRAPHICS INTO TOP CHANNEL OF BOTTOM
SUPPORT BAR TO POSTS AT BOTH ENDS AS PER STEP 5 INTO THE VERTICAL CHANNELS OF THE MAIN POST ON
WHEN TOP AND BOTTOM HORIZONTAL SUPPORT BARS
ARE ATTACHED, THE GRAPHIC SIDES MAY BE TUCKED
BOTH SIDES
HORIZONTAL SUPPORT BAR THEN CONNECT THE
SLIDE GRAPHICS INTO BOTTOM CHANNEL OF TOP
SUPPORT BAR TO POSTS AT BOTH ENDS AS PER STEP 5
1
5465 SW WESTERN AVE.
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
3
3
2
2
DIMENSIONS ARE IN MILLIMETERS
FINISH:
01
BEAVERTON, OR 97005
NIEDO GROUP, INC.
6
SHEETDO NOT SCALE DRAWING
REV
DWG. NO.
SCALE:
1
MATERIAL:
TOLERANCES
SIZE
TITLE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
UNLESS OTHERWISE SPECIFIED
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
SET UP INSTRUCTIONS
STEP 7
(GRAPHIC ATTACHMENT) THIS INSTRUCTION IS RELEVANT TO FRAME, END PANELS AND HORIZONTAL BARS.
10 FT. TIMBERLINE MODULAR DISPLAY
TL1002F-S

THIS SCREW ONLY
FINGER TIGHTEN
THIS SCREW ONLY
FINGER TIGHTEN
FINGER TIGHTEN
THIS SCREW ONLY
FINGER TIGHTEN
THIS SCREW ONLY
STEP 8
FOR ITEM #s PLEASE REFER
FRAME/SKIN ASSEMBLY MAY NOW BE INSERTED INTO THE TOP
ARCH TOP ASSEMBLY AND ATTACHMENT
TOP FABRIC NOT SHOWN FOR CLARITY
OF DESIGNATED TIMBERLINE POSTS (ITEM #1)
WAVE TOP ASSEMBLY AND ATTACHMENT
TO ASSEMBLY DIAGRAM ( TOP ASSEMBLY AND ATTACHMENT )
COMPONENTS OF THE WAVE TOP FRAME ARE LABELED FOR EASY
ASSEMBLY. WHEN THE WAVE TOP FRAME IS ASSEMBLED
SLIDE THE FABRIC COVER OVER LIKE A PILLOW CASE AND ZIP UP.
WHEN THE COVER IS ON THE FRAME, INSERT THE MOUNTING
SCREWS THROUGH THE HOLES PROVIDED AND THREAD INTO THE
WAVE TOP SUPPORT POST (ITEM#3) IN THE BOTTOM SIDE, BE
SURE TO FINGER TIGHTEN ONLY. WAVE TOP SUPPORT POST AND
10 FT. TIMBERLINE MODULAR DISPLAY
TL1002F-S
5465 SW WESTERN AVE.
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
FINISH:
01
BEAVERTON, OR 97005
NIEDO GROUP, INC.
6
SHEETDO NOT SCALE DRAWING
REV
DWG. NO.
SCALE:
SIZE
1
DIMENSIONS ARE IN MILLIMETERS
MATERIAL:
TITLE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
UNLESS OTHERWISE SPECIFIED
TOLERANCES
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
SET UP INSTRUCTIONS

REVERSE TO UNLOCK
DETAIL A
TURN TO LOCK
INTERLOCK MECHANISM
10 FT. TIMBERLINE MODULAR DISPLAY
1X 15.75" Z-4400 EXTRUSION
STRAIGHT SIDES ASSEMBLY DETAIL
AT THE TOP AND 1X 8.75" Z-4400
TIMBERLINE POST
8.75" Z-4400 EXTRUSION
END PANEL GRAPHIC
AND INTERLOCK MECHANISM
15.75" Z-4400 EXTRUSION
METAL FUSION END PANELS
TL1002F-S
A
AS SHOWN IN DETAIL A
ATTACHED AS IN
A
TAPERED SIDES ASSEMBLY DETAIL
STEP 7
TIMBERLINE POST
PANELS ARE ATTACHED WITH
TIMBERLINE STRAIGHT END
ATTACHED AS IN
END PANEL GRAPHIC
END PIECES
2X 15.75" Z-4400
AT BOTTOM. BOTH EXTRUSIONS
SHOWN IN DETAIL A
THE INTERLOCK MECHANISM
ARE FASTENED TO POST USING
STEP 7
2X 15.75" Z-4400 EXTRUSIONS TIMBERLINE TAPERED END
PANELS ARE ATTACHED WITH
GRAPHIC HEADER
MOUNTING BRACKET
(ITEM #10)
TIMBERLINE POST
TIMBERLINE METAL FUSION
ROUNDED AND TAPERED END
PANELS ARE ATTACHED WITH
GRAPHICS HEADER MOUNTING
BRACKETS AS IN STEPS 4 & 6.
BRACKETS SLIDE INTO THE CHANNEL
ON THE TIMBERLINE POST AND ARE
POSITIONED AS SHOWN. SLIDE THE
METAL FUSION PANEL INTO THE
BRACKETS AND FINGER TIGHTEN
THE THUMB SCREWS.
METAL FUSION
ROUNDED END PANEL
METAL FUSION
TAPERED END PANEL
1
5465 SW WESTERN AVE.
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
3
3
2
2
DIMENSIONS ARE IN MILLIMETERS
FINISH:
02
BEAVERTON, OR 97005
NIEDO GROUP, INC.
SHEETDO NOT SCALE DRAWING
REV
DWG. NO.
SCALE:
1
MATERIAL:
TOLERANCES
SIZE
TITLE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
UNLESS OTHERWISE SPECIFIED
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
SET UP INSTRUCTIONS

REVERSE TO UNLOCK
DETAIL A
TURN TO LOCK
INTERLOCK MECHANISM
TIMBERLINE
ATTACHED TO THE FRONT OF
POST
THE TIMBERLINE POST USING A
A FRAMEWORK OF Z4400
MECHANISM, AS SHOWN.
THE SLAT WALL WOOD ASSEMBLY IS
TIMBERLINE POST
INTERNALLY THREADED COSMETIC
TIMBERLINE POST
IS ATTACHED TO THE SIDES OF
TL1002F-S
THE SLAT WALL WING ASSEMBLY
EXTRUSION AND INTERLOCK
SLAT WALL WINGS ASSEMBLY DETAIL
A
SLIDING THREADED INSERT AS
SLAT WALL WOOD ASSEMBLY DETAIL
10 FT. TIMBERLINE MODULAR DISPLAY
THREADED INSERT
KNURLED KNOB
THE TIMBERLINE POST USING
SHOWN, AND FASTENED USING AN
WASHER
KNURLED KNOB AND WASHER.
Z-4400
EXTRUSION
1
5465 SW WESTERN AVE.
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
3
3
2
2
DIMENSIONS ARE IN MILLIMETERS
FINISH:
01
BEAVERTON, OR 97005
NIEDO GROUP, INC.
SHEETDO NOT SCALE DRAWING
REV
DWG. NO.
SCALE:
1
MATERIAL:
TOLERANCES
SIZE
TITLE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD
UNLESS OTHERWISE SPECIFIED
- PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Timberline Modular Display
SET UP INSTRUCTIONS

OF ACRYLIC TABLE TOP FOR
(ALL HARDWARE IS PROVIDED)
ASSEMBLE TABLE LEGS TOGETHER
WITH THE TOP AND BOTTOM BASE
PLATES AND SCREWS. THEN
ATTACH THE ACRYLIC TABLE TOP
WITH THE LARGE BOLTS AND WING
NUTS TO TOP OF BASE PLATE ON
LEGS. ATTACH CLAMP TO BACK
INSERTION INTO VERTICAL POSTS.
A
OVERHEAD LAMPS
SLIDE THE BASE ADAPTER INTO THE BOTTOM OF
THE LAMP. THEN SLIDE THE LAMP INTO THE TOP
GROOVE OF THE HORIZONTAL SUPPORT.
HOOK IS FACING
TOWARDS REAR
DETAIL -A-
LARGE BOLTS AND WING NUTS.
OF BRACKET AND SECURE USING
TIMBERLINE SHELVES
TIMBERLINE ACCESSORY OPTIONS
TL1002F-S
ATTACH BRACKETS INTO
VERTICAL POSTS AND TIGHTEN.
PLACE ACRYLIC SHELVES ON TOP
10 FT. TIMBERLINE MODULAR DISPLAY
TIMBERLINE TABLE
1
1
5465 SW WESTERN AVE.
NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN
A A
B B
C C
D D
8
8
7
7
6
6
5
5
4
4
3
3
2
MATERIAL:
DIMENSIONS ARE IN MILLIMETERS
FINISH:
01
BEAVERTON, OR 97005
NIEDO GROUP, INC.
SHEETDO NOT SCALE DRAWING
REV
DWG. NO.
2
TOLERANCES
UNLESS OTHERWISE SPECIFIED
SCALE:
SIZE
TITLE
PART TO ANYONE WITHOUT PERMISSION OF NIEDO GROUP, INC.
PROJECTION
ANGLE
THIRD - PROPRIETARY -
THIS DOCUMENT AND DATA DISCLOSED HERIN OR HEREWITH IS
10 Ft. Wave Top Modular Display