5
TERMINALS
REMOVABLE BLOCK TERMINALS:
PIN NUMBER
1. ~AC (90V to 250V AC 50Hz/60Hz Live, Handle with care).
2. ~AC (90V to 250V AC 50Hz/60Hz Neutral, Handle with care).
3. Earth (To Earth Main line, Handle with care).
4. 0V (Common ground, Connect to POT).
5. 5V OUTPUT (For POT connection).
6. 12V OUTPUT (For NPN type proximity sensors).
7. Emer- EMERGENCY INPUT (Connect output of N/O, NPN type proximity switch).
8. 0V (Common ground, For NPN type proximity).
9. 0V (Common ground, Connect to STEPPER DRIVER e.g. TSTEP-484).
10. Speed (Connect to center of POT for speed input).
11, 12. NC- not connected.
13. X-STP- STEP PULSE OUTPUT for motor 1, i.e. motor for X-axis (Connect to
STEPPER DRIVER eq. TSTEP-484).
14. X-DIR - DIRECTION output for motor 1, i.e. motor for X-axis (Connect to
STEPPER DRIVER eq. TSTEP-484).
15. Y-STP- STEP PULSE OUTPUT for motor 1, i.e. motor for Y-axis (Connect to
STEPPER DRIVER eq. TSTEP-484).
16. Y-DIR - DIRECTION output for motor 1, i.e. motor for Y-axis (Connect to
STEPPER DRIVER eq. TSTEP-484).
17, 18. NC- not connected.
19. 0 V (Common Ground).
20. X- LIM Connect output of NO, NPN type proximity switch).
21. Y- LIM (Connect output of NO, NPN type proximity switch).
22. Start- Stop: Connect the on- off switch here.
23. Com-In (Common for X-Lim and Y- Lim inputs, can be supplied external 12 volt or
jumped from 12v output from the controller).
24. 12V OUTPUT (For NPN type proximity).