Setting Box Model: SB-FH2
● Do not drop water or oil on this instrument
Do not use this instrument in an atmosphere of ammable gas and steam.
Use in such an atmosphere may result in re.
● Avoid shock or vibration to this instrument. It may cause a damage or failure.
● Before use, make a pre-operation inspection and check the settings.
● Use only the specied battery. The battery may overheat, leak, or explode.
● When discarding or storing the battery, insulate it with tape or something.
● Should this instrument give out abnormal smell or catch re during use, stop using it
immediately and move the instrument to a safe place and contact Tohnichi Mfg. Co., Ltd.
● Be sure to use an 9V alkaline battery for power supply to the transmitter T-FHM/-FH.
● Remove the battery if the product will not be used for a long time.
● Avoid using the instrument in a place where there are metal structures around it.
● Avoid using the instrument near welding machines, electric discharge machines or
machines producing electromagnetic noise such as PC.
● When setting, be sure to set one by one. If multiple transmitters and receivers are set to
the setting mode at the same time, they cannot be set correctly.
● Do not disassemble or modify this product. It may result in loss of safety,
it may be punished by law.
Safety Precautions
To customers:
Before using this product, please read this operating instruction carefully to use it properly.
If you have any question, please contact your nearest distributor or Tohnichi Mfg. Co., Ltd.
This operating instruction should be stored in a safe place.
Safety symbol
This symbol indicates attention is required for your safety. When this symbol appears in this
instruction, pay particular attention for your safety concerns. Take preventative measures
according to the written message for appropriate operation and management.
!
Signal Words
A signal word accompanies the safety symbol, which indicates the level of cautions on safety of people and
the appropriate use of the equipment. Signal words are classied into 3 levels: "danger", "warning " and
"caution" by the degree of risk.
" Danger": Imminent danger which may cause serious damage
" Warning": Potential danger which may cause serious damage
" Caution": Potential danger which hinder ordinary operation but may not lead to serious damage.
!
!
!
Warning
!

Setting Box Model: SB-FH2
3
1. Outline
2. Feature
3. Components
4. Specications
5. External Figure and Part of Name
6. Precaution for Use
6-1. Power Source
6-2. Usage Environment
6-3. Precaution for Handling the Antenna
7. Handling
7-1. Basic Settings
7-2. How to Use
7-3. Battery Replacement
8. Trouble Shooting
9. Dimensions
4
4
4
5
6
7
7
7
7
8
8
10
17
18
19
■Contents

4
Setting Box Model: SB-FH2
1Outline
This setting box can perform various settings of FH/FD radio signal torque wrench series wirelessly.
Since it operates by itself, it is possible to change settings while carrying. In addition, by connecting to a PC and
using dedicated setting software to perform more detail setting easily
2Feature
● Easy transmitter / receiver settings
∙ Various settings such as group and ID can be conrmed wirelessly using the setting box without removing the
transmitter from the torque wrench or removing the receiver panel.
About groups and IDs
[Group] : 5ch extracted from 78ch frequency from 2.402GHz to 2.479GHz (1MHz interval) 1 group
There are 256 groups in total, and radio waves are transmitted and received using the 5ch frequencies in this
group.
[ID] : 000 to 999 and 7 alphanumeric characters can be set, and the receiver identies the torque wrench
with this ID.
● Easy battery replacement
The old setting box (SB-FH256) could not be replaced without removing the screw and removing the panel when
replacing the battery. However, the SB-FH2 can be easily replaced without using tools.
● Uses the worldwide 2.4GHz frequency band (ISM band)
Contact Tohnichi for status of wireless certication acquisition for each country.
● Remote setting function
Using the setting box SB-FH2, the receiver can be set remotely.
Easy to change the settings even after installing the receiver at a high place.
* Only for available for R-CM and M-FH module with set at M-FH mode. Refer to “7-2-3. Remote Setting.
3Components
Setting BOX: SB-FH2 R-CM receiver
with a radio module
Radio Signal Radio Signal
Wired
PC, PLC
RS232C
Setting data
Torque Wrench
QSPFHM / FH
Torque Wrench
QLFHSLS
Torque Wrench
QSPCAFHP
Torque Driver
RTDFH
Torque Wrench
CSPFD / CSPFDD
Receiver
R-FHD256

Setting Box Model: SB-FH2
5
4Specications
Model SB-FH2
Frequency band 2..402GHz - 2.479GHz 1 MHz interval 78 kinds
Communication method Spread spectrum (FHSS)
Modulation GFSK
Group channel 256 (000-255)
In/Output RS232C
Power source [DC] V 9 V alkaline battery x 1
Antenna Dipole antenna
Temperature 0-50
Distance 10-20m *
Weight 0.9kg
*1. 10 hours in use with a bland new battery.
*2. Communication distance varies depending on the radio environment.

6
Setting Box Model: SB-FH2
5External Figure and Part of Name
Dipole Antenna Connector Display
Battery Cover Serial No.
RS232C Connector
160
12035
● Dipole antenna connector
Connector for attaching a dipole antenna.
● Power switch
Power ON/OFF the main unit
● GET button
For conrmation of the currently settings of the transmitter or receive
● SET button
For updating the settings of transmitter or receiver.
● LEFT key
This switch moves the cursor to the
● RIGHT key
This switch moves the cursor to the right.
● UP key
This switch moves the cursor up.
● DOWN key
This switch moves the cursor to the right.
● Battery cover
Open this battery cover and replace the battery.
● RS232C connector
Connect it to PC to use dedicated setting software to change settings of the Transmitter and receiver. Use
RS232C straight cable.
● Version sticker
Shows the software version of the setting box

Setting Box Model: SB-FH2
7
6Precaution for Use
6-1. Power Source
Make sure to use 9V alkaline battery.
6-2. Usage Environment
● Use the product where there is no metal structure around as much as possible.
● Do not place the antenna of the receiver in the immediate vicinity of metal pillars, electric wires, iron pipes, etc.
* Especially when the antenna and piping are parallel, the communication status may deteriorate.
● Avoid using in the vicinity of machines that generate electromagnetic noise, such as welding machines,
electrical discharge machines, and personal computers.
*If the receiver where the ID is set on a different channel in the same group is placed adjacent to the transmitter,
in extremely rare cases when "simultaneous transmission" occurs, a communication error may be caused.
6-3. Precaution for Antenna
Refer to the following instructions when mounting or dismounting an antenna on R-CM, M-FH or
SB-FH2.
Do not turn antenna itself. Hold the antenna and turn the notched end. Otherwise, antenna joint of the receiver
will be damaged, and the receiver cannot receive signals denitely.
Hold the antenna not to rotate

8
Setting Box Model: SB-FH2
7Handling
7-1. Basic Settings
Cursor
Group
000 - 255
Judgment code
0 - 3
3-digits ID
000 - 999
7-digits alphanumeric
Previous page
0 0 0 0 0 0 0
0 0 0 0 0 0 0
N E W 0 0 0 0 0 0 0
N E W 0 0 0 0 0 0 0
Next page
Upper row: Current setting
Bottom: Update
Upper row: Current setting
Bottom: Update
● Group
Communication is possible by setting the transmitter and receiver to the same group.
Group 000 to 255 is available
● 3-digit ID
This ID is necessary for identifying the torque wrench.
000 to 999 can be set.
● 7-digit ID
Seven alphanumeric characters necessary for torque wrench identication.
Set the serial number and control number of the torque wrench.
● Judgment code
0: 3-digit ID, 7-digit alphanumeric characters without identication.
When multiple torque wrenches are used with one receiver.
Applicable only when simultaneous transmission is not performed).
1: 3-digit ID with identication.
2: 7-digit alphanumeric characters with identication.
3: 3-digit ID, 7-digit alphanumeric characters with identication.
* Must be set the same judgment code for the transmitter and the receiver.

Setting Box Model: SB-FH2
9
● Change of settings
1. Press the GET switch to display the current setting in the upper row, and press the SET switch to send the
lower setting.
* When sending the settings, only the items displayed are sent without sending the settings on another page.
2. When OK is displayed, the setting has been received or transmitted.
When NG is displayed, the transmitter or receiver may not been set in the setting mode.
Enter the setting mode and press GET / SET again.
3. After changing the setting, press the GET switch and conrm that the upper and lower stages are set to
the same setting value.
4. When the setting change is completed, exit the transmitter or receiver setting mode and press the
power switch on the setting box to turn off the power.

10
Setting Box Model: SB-FH2
7-2. How to Use
* Be sure to set one unit at a time. If multiple transmitters and receivers are set to the setting mode at the
same time, they cannot be set correctly.
1. Attach the dipole antenna (standard accessory) to the setting box.
2. Set the transmitter or receiver at setting mode.
* For how to enter the setting mode, see the instruction manual of the target product.
* You can use this device to enter the R-CM receiver setting mode with the remote control.
Refer to “7-2-3 Remote Setting for details.
3. Conrm that the following is displayed on the display when the power switch is pressed.
software version
TOHNICHI MFG
SETTING BOX O O
4. When power ON, following setting mode selection screen will appear.
Select the setting item with the direction switch and press the SET button to enter.
Setting mode
MODE SELECT
FH/FD