TOPP TF21 Bedienungs- und Wartungshandbuch

BEFORE INSTALLING AND USING THE DEVICE, IT IS COMPULSORY FOR
THE INSTALLER AND THE USER TO READ AND UNDERSTAND
THIS MANUAL IN ALL ITS PARTS.
THIS MANUAL IS INTEGRAL PART OF THE DEVICE
AND MUST BE PRESERVED FOR FUTURE
REFERENCE UNTIL DEMOLITION OF THE SAME.
TF21/24R/T
TF41/44R/T
INSTALLATION AND USE INSTRUCTIONS
FEEDING AND CONTROL UNIT
FOR 24VDC / 230VAC MOTORS
P/N 8P5021
VER.1.0 REV.07.04


3
INDEXTF21/44R/T
INSTALLATION AND USE INSTRUCTIONS
1- DECLARATION OF "CE" CONFORMITY ....................................page 04
2- GENERAL REMARKS
2.1- General instructions ..........................................................................page 05
2.2- Installer and user...............................................................................page 05
2.3- Warranty............................................................................................page 05
2.4- Technical assistance..........................................................................page 05
2.5- Reserved rights (Copyright) ..............................................................page 05
3- TECHNICAL DESCRIPTION
3.1- Rating plate and "CE" marking..........................................................page 06
3.2- Denomination of the components and dimensions ...........................page 07
3.3- Technical data ...................................................................................page 08
3.4- Destination of use .............................................................................page 08
3.5- Use Limits .........................................................................................page 09
3.6- Package ............................................................................................page 09
4- SAFETY
4.1- Protections against electric hazard ...................................................page 10
4.2- Residual risks....................................................................................page 10
5- INSTALLATION
5.1- General instructions ..........................................................................page 11
5.2- Installation of the sensors..................................................................page 11
5.3- Installation of the power supply unit ..................................................page 12
5.4- Tripping of the sensors......................................................................page 13
5.5- Technical information on operation ...................................................page 13
5.6- Automatic operation with predefined logic.........................................page 13
5.7- Programming of remote electronic control mod. F33 ........................page 16
5.7.1- Programming reset.........................................................................page 17
5.8- Electric connections ..........................................................................page 18
6- USE AND OPERATION
6.1- Use of the device...............................................................................page 23
7- DEMOLITION
7.1- General instructions ..........................................................................page 24
8- SPARE PARTS AND ACCESSORIES UPON REQUEST
8.1- General instructions ..........................................................................page 24
8.2- Accessories upon request .................................................................page 24
VER.1.0
REV.07.04

TOPP SPA - Via Galvani, 59
36066 SANDRIGO (VI) - ITALIA
Tel. +39 0444656700
Fax +39 0444 656701
Declares that the electric device
called: FEEDING AND CONTROL UNIT FOR 24VDC/230VAC MOTORS
Type: TF Models: TF21 - TF21R/T - TF24 - TF24R/T 24VDC
TF41 - TF41R/T - TF44 - TF44R/T 230VAC
Serial No.: see rating plate and CE marking applied on the device
Year of construction: 2004
complies with the requirements of the following directives:
73/23/EEC
(Low Voltage Directive: electrical equipment destined to be used within given voltage limits)
89/336/EEC
(Electromagnetic Compatibility Directive - on the approximation of the laws of the
Member States relating to electromagnetic compatibility)
and, besides, it declares that the following harmonized standards have been
applied:
EN 60950:1992- 08; EN 60950 EC:1992-10; EN 60950/A1:1993;
EN60950/A2:1993- 08; EN 60950/A3:1995- 10; EN 60950/A3 EC:1996- 01;
EN 60950/A4:1997- 03; EN 60950/A11:1997- 10; EN55022:1998;
EN61000- 3- 2:1995; EN61000- 3- 3:1995; EN61000- 3- 2/A1:1998;
EN61000- 3- 2/A2:1998; EN50130- 4:1995; EN50130- 4/A1:1998
Date: 07/01/2004
Surname and name: Matteo Cavalcante
Signature...........................................................
4
TF21/44R/T
INSTALLATION AND USE INSTRUCTIONS
1- DECLARATION OF "CE" CONFORMITY
VER.1.0
REV.07.04

2.1- GENERAL INSTRUCTIONS
BEFORE INSTALLING AND USING THE DEVICE, IT IS COMPULSORY THAT THE
INSTALLER AND THE USER CAREFULLY READ AND UNDERSTAND THIS MANUAL IN
ALL ITS PARTS.
THIS MANUAL IS INTEGRAL PART OF THE DEVICE AND MUST COMPULSORILY BE
PRESERVED FOR FUTURE REFERENCE.
THE MANUFACTURER HAS NO LIABILITY FOR ANY EVENTUALDAMAGE TO PERSONS,
ANIMALS AND THINGS DUE TO THE INOBSERVANCE OF THE STANDARDS DESCRIBED
IN THIS MANUAL.
2.2- INSTALLER AND USER
THE DEVICE INSTALLATION CAN BE PERFORMED EXCLUSIVELY BYCOMPETENT AND
QUALIFIED TECHNICAL PERSONNEL SATISFYING THE PROFESSIONAL AND
TECHNICAL REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRYOF
INSTALLATION.
THIS DEVICE CAN BE USED EXCLUSIVELY BY A USER ACTING IN CONFORMITY WITH
THE INSTRUCTIONS CONTAINED IN THIS MANUAL.
2.3- WARRANTY
THE DEVICE WARRANTY EXPIRES, IF ITS USE DOES NOT COMPLY WITH THE
INSTRUCTIONS AND PRESCRIPTIONS DESCRIBED IN THIS MANUAL, AS WELL AS IF
NON-ORIGINAL COMPONENTS, ACCESSORIES, SPARE PARTS, AND CONTROL
SYSTEMS ARE USED (SEE LAST PAGE).
2.4- TECHNICAL ASSISTANCE
For the technical assistance apply to your Dealer or to the Manufacturer.
2.5- RESERVED RIGHTS
The reserved rights on this manual "Installation and use instructions" remain property of
the Manufacturer.
Each information herein contained (text, drawings, diagrams, etc.) is reserved.
None part of this manual can be reproduced and disclosed (totally or partially) by any
reproduction means (photocopies, microfilms or other) without written authorization of
the Manufacturer.
5
TF21/44R/T
INSTALLATION AND USE INSTRUCTIONS
GENERAL REMARKS -2
VER.1.0
REV.07.04

3.1- RATING PLATE AND "CE" MARKING
The CE marking certifies the compliance of the machine with the essential safety and
health requirements foreseen by the product European Directives.
The rating plate is an adhesive plate in polyester, silk-screen printed in black, having the
following size: L=36 mm - H=50 mm.
It is applied externally on the device. The plate (Fig.1) bears in readable and indelible
way the following data:
• logo and address of the manufacturer
• type and model
•
• output voltage (A)
• absorbed electric power P (W)
• symbol of double insulation
• CE marking
• serial number
• year of construction
Power supply voltage and frequency (V-Hz)
6
TF21/44R/T
INSTALLATION AND USE INSTRUCTIONS
3- TECHNICAL DESCRIPTION
VER.1.0
REV.07.04

7
3.2- DENOMINATION OF THE COMPONENTSAND DIMENSIONS
Fig.2 Dimensions in mm
TF21/44R/T
160
120
75
INSTALLATION AND USE INSTRUCTIONS
TECHNICAL DESCRIPTION -3
230V - 50Hz MAINS WIND
SENSOR
RPR RAIN
SENSOR
SUN
SENSOR
CONTROLS OF ALL
MOTORS CONNECTED
FEEDING AND
CONTROL UNIT
CONTROLS OF
SINGLE OUTPUTS
24Vdc/230Vac MOTORS
(see Table 1)
INFRARED RAY
REMOTE CONTROL
433 Mhz RADIO
CONTROL
VER.1.0
REV.07.04

3.3- TECHNICAL DATA
Tab.1 contains the technical data characterising the device.
8
Tab.1
230 V - 50 Hz
230 Vac
TF21/RT TF24/RT TF41/RT TF44/RT
0,36 A 1,5 A
15 W 45 W
Yes
- 5 ºC + 50 ºC
160 x 120 x 75 mm
1,3 kg
24 Vdc
1,3 A 5,2 A
300 W 1200 W
TF21/44R/T
3.4- DESTINATION OF USE
THE DEVICE HAS BEEN DESIGNED AND MANUFACTURED ONLY TO FEED AND
CONTROL "ORIGINAL TOPP" MOTORS: WINDOW AUTOMATION ACTUATORS - MOD.
C20 - ACK4 - SL60 - C30 - C40.
INSTALLATION AND USE INSTRUCTIONS
3- TECHNICAL DESCRIPTION
Power supply voltage
Output voltageVdc - Vac
Max. output current
Absorbed power
Service
Prearrangement connection
to external devices
Double electric insulationyes
Operating temperature
Dimensions
Connectable C20 actuators
Connectable ACK4 actuators
Connectable SL60 actuators
Connectable C30 actuators
Connectable C40 actuators
Gross weight
Wind, rain, brightness sensors
and manual control
According to the motors connected
VER.1.0
REV.07.04
N.2
N.4
N.4
N.8
N.16
N.16
N.4
N.1
N.1
N.1
/ /
/
/ N.4 N.16
N.5 N.20N.1/

9
TF21/44R/T
3.5- USE LIMITS
3.6- PACKAGE
The device has been designed and manufactured exclusively for the destination of use
given in par.3.4, therefore, any other type of use is strictly forbidden in order to assure
in any moment the safety of the installer and of the user, as well as the efficiency of the
device itself.
IT IS STRICTLY FORBIDDEN TO USE THE DEVICE FOR IMPROPER USES, DIFFERING
FROM THE ONE FORESEEN BY THE MANUFACTURER (SEE PAR.3.4).
IT IS STRICTLY FORBIDDEN TO INSTALL THE DEVICE ON THE EXTERNAL SIDE OF THE
ROOM SUBJECT TO ATMOSPHERIC AGENTS (RAIN, SNOW, ETC.).
THE USE OF THE DEVICE IN ENVIRONMENTS WITH POTENTIALLY EXPLOSIVE
ATMOSPHERE IS STRICTLY FORBIDDEN.
IT IS COMPULSORY TO KEEP THE PACKAGE AND THE DEVICE OUT OF REACH OF
CHILDREN.
Each standard package of the product (cardboard box) contains:
• No. 1 Feeding and control unit for 24VDC/230VAC motors;
• No. 3 Fairleads (ø 6) for connection cables;
• No. 1 Package with dowels and fastening screws;
• No. 1 433 MHZ Radio control (only for mod. TF21R, TF24R, TF41R and TF44R);
• No. 1 Infrared remote control (only for mod. TF21T, TF24T, TF41T and TF44T);
• No. 1 Installation and use instructions.
MAKE SURE THAT THE ABOVE DESCRIBED COMPONENTS ARE CONTAINED IN THE
PACKAGE, AS WELL AS THAT THE DEVICE HAS NOT BEEN DAMAGED DURING
TRANSPORT.
SHOULD ANY ANOMALY BE DETECTED, IT IS FORBIDDEN TO INSTALL THE DEVICE,
AND IT IS COMPULSORY TO REQUIRE TECHNICALASSISTANCE FROM YOUR DEALER
OR THE MANUFACTURER.
THE PACKAGING (PAPER, PLASTIC, ETC.) HAS TO BE DISPOSED ACCORDING TO THE
LAWS IN FORCE.
EX
INSTALLATION AND USE INSTRUCTIONS
TECHNICAL DESCRIPTION -3
VER.1.0
REV.07.04

4.1-
4.2-
PROTECTIONS AGAINST ELECTRIC HAZARD
The device is protected against electric hazard due to direct and indirect contacts.
The protection measures against direct contacts aim at protecting people against
hazards due to contact with active parts, usually live parts; while the protection
measures against indirect contacts aim at protecting people against hazards due to
conducing part, which are usually insulated, but could become live in case of failure
(insulation failure).
The adopted protection measures are the following:
1) Insulation of live parts by means of a plastic material body;
2) Enclosure with suitable protection degree;
3) Protection of passive type given by the use of components with double insulation,
also called components of class II or with equivalent insulation (it is forbidden to
perform the connection to the earthing plant of the devices equipped with double
insulation).
RESIDUAL RISKS
The device does not have residual risks. The installer and the user are herewith
informed that after the actuators have been installed on the window, the automatic
enabling of the same can accidentally generate the following residual risk:
Residual risk:
Hazard of squashing or dragging of body parts inserted between the movable and the
fix part of the window frame.
Exposure frequency:
Accidental and when the installer or the user decides to perform a wrong voluntary
action.
Severity of the damage:
Light lesions (usually reversible).
Adopted measures:
1) Manual control (remote control, radio control or push-button): It is compulsory to
verify that near the window there are not persons, animals or things whose safety
may be accidentally jeopardized. During actuator operation, it is compulsory to be in
a safe control position assuring visual control on the window movement.
2) Automatic control (sensors): It is compulsory to place on the window suitable safety
signals and/or to install a suitable acoustic/light signaller nearby.
10
TF21/44R/T
INSTALLATION AND USE INSTRUCTIONS
4- SAFETY
VER.1.0
REV.07.04
Dieses Handbuch passt für folgende Modelle
11
Inhaltsverzeichnis
Andere TOPP Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung