Follow these instructions to clean the emitter point:
1. Turn off power and unplug ionizer.
2.
1.
Remove the output nozzle tip and ceramic insulator.
2. Moisten a swab in the IPA solution.
3. Swab or wipe the emitter point until it is free of
particles.
4. Make certain the emitter point is straight and undam-
aged.
5. Replace the output nozzle tip and insulator.
6. Make sure the emitter points are dry before powering the
ionizer again.
Emitter Point Replacement
The IN6430 uses tungsten alloy precision etched emit-
ter needles. Contact Transforming Technologies for infor-
mation about ordering replacement emitters. The part num-
ber for emitters is listed below:
Replacement part Part Number
IN6430 tungsten replacement emitters 22-6433
Because the IN6430 high voltage output is AC, emitter
erosion from the ionization process on the electrodes is
minimal. Unless physically broken or stressed, the IN6430
emitters should last the life of the ionizer.
Follow these instructions to remove the emitter points:
1. Turn off and disconnect the unit from the AC power.
2. Remove the output nozzle.
3. Unscrew the threaded emitter point using a needle nose
pliers.
4. Replace and tighten the new emitter using the same
tool. Do not over-tighten.
5