WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 03 / 29
1 Safety instructions
Please read the safety instructions, provided in a separate manual, carefully. Make sure that the
environmental, mounting, and installation prerequisites are met. This manual should be kept at a safe place
and in reach of the device.
1.1 Symbols
!
The exclamation mark warns about possible
damage of the device itself, to connected devices,
and to the user.
The information symbol gives general hints and
informs about handling and procedures for use of
the device.
1.2 General safety instructions
2 General device description
e:cue SYMPL Nodes are a system of interfaces for e:cue SYMPHOLIGHT only. They provide various
connection types like DMX512, DALI, digital inputs and outputs etc. SYMPL Nodes always operate in online
mode, as a device interface for SYMPHOLIGHT. All interactions are initiated and controlled by
SYMPHOLIGHT. Connections between servers, Cores and Nodes are always made with e:net via Ethernet.
The SYMPL pixel Node is a LED pixel controller, converting e:net to control a wide range of supported serial
addressable LED pixels like digital LED strips, dots and boards with multi controllable pixel. Control a wide
range of supported asynchronous and synchronous like SPI LED pixels and congure content with e:cue’s
SYMPHOLIGHT. It comes with 2 x Pixel outputs over screw terminal plugs. Choose the output protocol
separately for each of the two outputs. The Node makes it possible to run up to 2 x 2048 channels (= 4096 in
total, = 1364 RGB pixels) over Ethernet. Connection to the server runs via Ethernet interface with 100 Mbit/s.
The Node is powered by an external power supply, Power-over-Ethernet, or a via pass back power from the
connected xture. It is easily mounted on standard 35 mm DIN rails, or with a key hole in the housing base on
walls or on any stable vertical surface. Cover distances of up to 300 m* between the Node to the xture with
the optional Pixel Range Extender (page 13).
— Connect cables and data only when the device is powered
down.
— When using a power supply unit, the device must be
supplied by a separate power supply that is certied
according to the local regulations (e.g. SELV, Class 2).
— The Ethernet port of the SYMPL Node is not designed for
inter-building connections with power and lighting
transients. Use only intra-building networks to connect
the SYMPL Nodes and Cores.
— If safety instructions are missing, please contact Traxon
e:cue to receive a new copy.
To operate the SYMPL pixel Node a SYMPHOLIGHT version
5.1 or higher is mandatory. Earlier versions do not support
the SYMPL pixel Node.
SYMPL pixel Node — Information for Use | Safety instructions
content