Triplett HSDL300 Bedienungsanleitung

User Manual
HSDL300
Heat Stress/ WBGT Datalogger

2
Introduction
Thank you for purchasing the Triplett HSDL300
Heat Index WBGT Datalogger. The HSDL300
meter measures air temperature, globe
temperature, and humidity to give heat stress
for using in control of physical activity in hot
environment to limit the danger of
heat-related injuries
WBGT (wet-bulb globe temperature) was
developed as a monitoring basis at US military
training camps and became widespread for the
use in workplaces and sports situations.
The applications of the heat index can be in
construction, iron and steel foundries, bricks-
firing plants, glass facilities, boiler rooms,
mining sites, army training, marathon, beach
activities and so on.
Features:
Direct measurement of the radiation
Effect with a brass black ball.
Adjustable WBGT alarm threshold
Audible beeper for heat stress
monitoring
Sensor protecting mechanism
Backlight indicator function (Green,
yellow, red, flashing red )
PC connect for auto logging
Controls and Indicators
LCD display

3
Icons and Symbols
WBGT Wet Bulb Globe Temperature
TG Black Globe Temperature
TA Air Temperature
RH/% Relative Humidity
OC/OF
Celsius/Fahrenheit
IN Indoor (no sun)
OUT Outdoor (full sun)
APO Auto Power Off
REC Recording
MAX Maximum
MIN Minimum
FULL Memory Full
Low battery indicator
Alarm indicator
Hold Function

4
Function Buttons
-Press power key to turn
on/off the meter. When
meter is powered on, APO
displayed on LCD.
-Press + key to turn
on the meter in non-APO
mode. NO APO on LCD.
-You will see the firmware
version on the LCD for 1
second while power on.
-In normal mode, press
TA/TG key to switch the
displayed temperature from
TA to TG or TG to TA.
-In normal mode, press
MAX/MIN key to switch the
displayed parameter to
max/min and then return to
normal. The value is counted
from power on. If you want
to reset the value, power off
the meter. (Note: Max/Min
value will be show on LCD for
60 seconds then return to
normal mode automatically.
-In setup mode, press this
key to exit from setup and
return to normal mode.

5
-In normal mode, long press
SET key to enter setting
mode.
-In setup mode, Key is
used for setting / save.
-In logging standby status,
press this key to start or stop.
-In normal mode, press IN/
OUT key to switch the WBGT
mode as Indoor or Outdoor.
-In setup mode, press this
key to increase the value.
-Press HOLD key to freeze
current reading. appears
on LCD. Press again to
release.
-In Setup Mode, press this
key to decrease the value.
-While press HOLD to freeze
the reading, it also activate
the back light. The back light
color was change with WBGT
value. See below.
Press key again to
release and turn off the
back light.
Above 32.2OC: Flashing Red
31~32.2OC: Red
29.4~31OC: Yellow
26.7~29.4OC:
Green
Below 26.7OC: No backlight
-Long press till icon
flashing on display to
indicate the logging function
is in standby status.

6
Operation
1.
POWER ON/OFF
Press to turn on and turn off the
meter. All indicators are shown on
the LCD when power on, and then
enter measuring mode. You will
see the firmware version on the
LCD for 1 second while power on.
2.
MEASUREMENT
Slide down the protecting sheath
of sensor before measurements.
Display mode
The meter measures TA (Air Temp),
TG (Globe Temp), RH (Relative
Humidity), and calculates WBGT
will be shows on the LCD. (Fig. A)
.
IN/OUT switch
To measure WBGT without or with
direct sun exposure under IN/OUT
modes, hold down for more
than 1 second to switch.
Pull up to
protect sensor
Design patent
pending

7
3.
ALARM / UNIT SETTING
P1.0 WBGT alarm setting
P1.1 alarm buzzar ON/OFF
In normal mode, long press
key to enter setup mode. (See
below Fig.)When alarm is
programmed as ON, appears
on LCD. When the WBGT value
reaches the alarm threshold, the
icon and WBGT value will flash
with continuous beeper sound per
second. However, user can short
press key to pause the
buzzer, the buzzer then sound
every 1 min afterward. But, LCD
icon will flash until the WBGT
value return to normal.
Even if buzzer alarm is OFF,
WBGT value flash while reaches
the alarm threshold.
P1.2 alarm threshold
The default is setting as 31OC.
The adjustment range is
20OC~50OC. Press or key
to adjust and press key to
confirm. Note : 0.5 OC per step
When in normal mode, press
key can cease the buzzer
but bell icon remain flashing
until the measured WBGT is
returned to normal.

8
P2.0 Unit setting
P2.1 temperature unit OC /OF
switch
Press up/down key to switch
between OC and O F and then
press key to confirm.
4.
DATALOGGING
Before each recording, connect
with computer to setup (see page
8). While ready, long press
till flashing on display. During
flashing, press to start.
To stop logging, long press
till flashing and then press
to stop.
5.
BATTERY REPLACEMENT
appears on the LCD when battery
voltage gets low. Please replace
battery by opening the compartment
on the rear of the meter.
6.
AUTO POWER OFF
The meter turns off automatically
after 15 minutes non operation.
To override the
function, hold down
and for 2
seconds to turn on
the meter. The LCD
will display “n”
and then enter
measuring mode.
7.
TRIPOD MOUNTING
The meter can fit on a tripod for long
time monitoring. A built-in thread is on
the bottom side of the meter.

9
Datalogger Setup
There is no need to install USB driver or
software before operating logging
function. Setup logger every time before
you want to start logging function.
Connect to computer to setup
Connect the logger with any windows
computer. Computer will recognize
logger as a CD-ROM and pop up new
screen for configuration. If not, you may
go to file management to click a
recognized CR-ROM called “Logger “
Double click “Logger configuration tool”
to setup the logger. The logger
configuration screen offers 8 languages
to help you setup easily. The
programmable parameters are sampling
rate, start delay time and Logger ID.
-The programmable sampling rate is
from 1 min to 2 hours
-The start delay time is from 0 min to 12
hours
Note:By choosing 5 mins, it means the
first record will be taken into logger’s
memory 5 mins after you pressing the
start key of logger.
-Logger ID is a 4 digit number you can
use to give each logger a unique
property code, such as 0928.
After setting, click Save to synchronize
the setting and your PC time zone to
datalogger.
Close the setup screen
Disconnect logger and leave it to the
place where you want to monitor the
WBGT. Remember to push down the
transparent protection shield.
Step1:
Step3:
Step2:

12
H
H
ic
H
Press keys to start logging
Long press key for more than 1
second to activate the logger into
standby status. You will see icon
flashing on display.
During icon is flashing, pressing
key to start the logging. You will see
REC icon flashes on display.
If the logger is programmed as start
delay 5 mins, after pressing key,
the REC icon will consistent display
and then turn into flashing after 5 mins
It will take 15 ~20 mins to make the
WBGT logger to reach equilibrium with
testing environment
Press keys to stop logging
To stop recording before memory is full,
long press key till H
on flash on
display and then press key during
the icon is still flashing to stop the
recording. REC icon will disappear from
display
There are 12000 records memory space,
while memory is full, FULL icon will
appear on display.
Connect to computer to read out
The procedure is same like connecting
to setup. Pressing download button on
setup screen and choose where to save
the logged file to. The read out csv report
can be opened by windows excel.
The saved report contains Configuration
Time, Start Time, Start delay, Sampling
rate, ID no. and Total records number.
Each record contains Date and time,
IN or OUT, TA, RH(%), TG and WBGT
Step2:
Step1:
Inhaltsverzeichnis
Andere Triplett Datenlogger Handbücher

Triplett
Triplett SLDL20 Bedienungsanleitung

Triplett
Triplett EMDL700 Bedienungsanleitung

Triplett
Triplett RHDL60 Bedienungsanleitung

Triplett
Triplett ACDL100 Bedienungsanleitung

Triplett
Triplett RHDL50 Bedienungsanleitung

Triplett
Triplett ACDL200 Bedienungsanleitung

Triplett
Triplett GSM220 Bedienungsanleitung

Triplett
Triplett ADL20 Bedienungsanleitung