Trueheat RCB Infrared Gas Broiler—September 2017 Page 1 of 16
INSTALLATION & OPERATION MANUAL
RCB
INFRARED GAS
BROILER

Trueheat RCB Infrared Gas Broiler—September 2017 Page 2 of 16
CONGRATULATIONS!
Thank you for choosing Trueheat.
This product has been specifically designed by Comcater to meet a wide range of applications
and represents the best quality and highest value equipment.
Please read the instruction manual carefully to ensure the safe and reliable operation and
performance of your equipment.
Should you require service, you will be supported by Comcater’s trained and qualified service
network.
COMCATER AUSTRALIA
www.comcater.com.au
National Head Office
156 Swann Drive, Derrimut, VIC 3030
Phone: 03 8369 4600
Fax: 03 8369 4699
Email: sales@comcater.com.au
Technical Services Group
Phone: 1800 810 161
Fax: 03 8369 4696
Email:
Equipment Servicing (24/7)
service@comcater.com.au
Equipment Spare Parts
spares@comcater.com.au
Technical Support
techsupport@comcater.com.au
Comcater QR Codes
Comcater Website Log a Service Call Online Spare Parts Store
Reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorised in writing by Comcater. Comcater reserves the
right to change design and specifications without prior notice. © Copyright Comcater Pty Ltd, August 2017.

Trueheat RCB Infrared Gas Broiler—September 2017 Page 3 of 16
TABLE OF CONTENTS
INTRODUCTION
Warranty...........................................................................................................................4
Date Plate Location ..........................................................................................................4
WARNINGS................................................................................................................................ 5
GENERAL INFORMATION .........................................................................................................6
SPECIFICATIONS
Dimensions, Weight & Installation Drawings.................................................................... 7
Accessories & Optional Accessories ............................................................................... 7
Gas Configuration ........................................................................................................... 8
INSTALLATION
Gas Connection .............................................................................................................. 11
Installation Clearances ................................................................................................... 11
Levelling .......................................................................................................................... 11
CONVERSION INSTRUCTIONS ................................................................................................12
COMMISSIONING / BURNER ADJUSTMENT
Leak Test ....................................................................................................................... 12
Test Point Pressure ........................................................................................................ 12
Pilot Adjustment ............................................................................................................. 12
Target Adjustment .......................................................................................................... 12
OPERATION
First Time Use ................................................................................................................13
Daily Operation ...............................................................................................................13
MAINTENANCE
Daily Cleaning ................................................................................................................14
Recommended Service Plan .......................................................................................... 15
TROUBLESHOOTING
Burner will not light .........................................................................................................16
Broiler isn’t getting hot ....................................................................................................16

Trueheat RCB Infrared Gas Broiler—September 2017 Page 4 of 16
INTRODUCTION
GENERAL
This Trueheat RC Series is designed for commercial catering purposes only and is designed to
deliver high end performance to fulfill the busy demands within a commercial kitchen. incorporates
a wide range of design features. It is available in various appliances and configurations including:
Ranges with open burners, griddles and oven and as a top only unit.
Barbecues, salamanders, pasta cookers and deep fryers.
This versatility will satisfy a wide range of customer needs.
WARRANTY
12 months replacement of parts including labour, for goods found to be faulty due to defective
materials, manufacture and/or workmanship. This warranty is void if installation, operation and/or
maintenance of the equipment are not in accordance with manufacturer’s instructions and
recommendations.
Unauthorised modifications to the equipment will void the warranty and product certification.
All warranty work will be undertaken in normal working hours from Monday – Friday 8:00am to
4:00pm
Warranty does not extend to:
Damages caused in shipment
Damage as a result of incorrect installation
Damage as a result of incorrect operation
Damages caused by Unauthorised service and use of non-original parts
Gas supply issues to the equipment
Calibration of thermostats after 90 days
Failure resulting from improper maintenance
Failure as a result of tampering with, removal of, or changing any pre-set control or
safety device
After hours Service - Penalty rates apply for afterhours service.
Conditions as defined in Comcater terms and condition of sale, a copy of Comcater’s terms and
conditions of sale can be found at www.comcater.com.au/terms
For all warranty work, authorized service, genuine and authorized spare parts, please contact
Comcater Service 1800 810 161.
Please ensure you quote the Model and Serial Number of the unit.
The Model and Serial Number of the unit is recorded on the sales invoice, and also shown on
the top right side of the front control panel. The data plate is located behind the front control
panel.
NOTE: Data Plate is located behind the control panel

Trueheat RCB Infrared Gas Broiler—September 2017 Page 5 of 16
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY OR DEATH. THE
INSTRUCTION MANUAL MUST BE READ CAREFULLY BEFORE
INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
TO BE INSTALLED ONLY BY AN AUTHORISED PERSON IN
ACCORDANCE WITH AS 5601, LOCAL AUTHORITY, GAS,
ELECTRICITY, ANY APPLICABLE STATUTORY REGULATIONS AND
MANUFACTURER REQUIREMENTS.
THIS EQUIPMENT IS DESIGNED FOR COMMERCIAL CATERING
PURPOSES AND WILL GENERATE SIGNIFICANT HEAT. HOT
SURFACES WILL CAUSE BURNS. A HAZARD AND RISK
ASSESSMENT MUST BE UNDERTAKEN BY OWNERS AND ALL
OPERATORS MADE AWARE OF THESE.
DO NOT STORE OR USE FLAMMABLE LIQUIDS NEAR THIS
APPLIANCE.
DO NOT SPRAY AEROSOLS NEAR THIS APPLIANCE WHILE IT IS IN
OPERATION.
INSTALLATION CLEARANCES AS SPECIFIED MUST BE OBSERVED.
IF YOU SMELL GAS, TURN THE UNIT OFF AND THE MAIN GAS
SUPPLY VALVE TO THE UNIT. CONTACT YOUR GAS SUPPLIER OR
AN AUTHORISED PERSON.
BEFORE TURNING ON THE MAIN GAS SUPPLY, CHECK THE UNIT TO
BE CERTAIN THAT ALL THE VALVES ARE IN THE “OFF” POSITION.
WARNINGS

Trueheat RCB Infrared Gas Broiler—September 2017 Page 6 of 16
GENERAL INFORMATION
INSPECTION
Please inspect the unit on receipt. If the unit is damaged, contact the carrier immediately
and file a damage claim with them. Save all packing materials when filing a claim. Freight
damage claims are the responsibility of the purchaser and are not covered under warranty.
OPERATOR MANUAL
This manual contains important information for your safety and the installation,
operation, maintenance and service of this equipment. Please read the manual carefully
and ensure all operators of the equipment are aware of the contents and safety
requirements. You must also assess all hazards and risks associated with the operation
of the equipment in your environment and advise all operators of these.
INSTALLATION
This equipment must be installed by an authorized person in accordance with AS 5601,
local authority, gas, electricity, any applicable statutory regulations and manufacturer
requirements.
GAS CONNECTION
The appliance must be connected by an authorized person to the gas type specified on
the unit. The gas type is shown adjacent to the rear gas connection point and on the data
plate. Connect to and use only the correct type of gas.
GAS PRESSURE
The authorized person installing this equipment must ensure that the gas operating pressure is
the same as shown on the rating plate and that there is sufficient gas volume for the appliance to
operator correctly.
COMMISSIONING
The authorized person installing this equipment must commission the equipment in accordance
with AS 5601 - gas leakage, operational checking, adjustments and instructing the owner on use
of the equipment are prescribed requirements.

Trueheat RCB Infrared Gas Broiler—September 2017 Page 7 of 16
SPECIFICATIONS
DIMENSIONS, WEIGHT & INSTALLATION DRAWINGS, OPTIONAL ACESSORIES
The following tables and drawings provide all dimension, weight and optional accessories.
DESCRIPTION RCB4 RCB6 RCB9
Weight (kg) 56 92 132
Width (mm) 400 600 900
Depth (mm) 803 803 803
Height (mm) 445 445 445
Height on stand
(mm) 1135 1135 1135
IMAGE PART NO. DESCRIPTION Qty
RCSTD4 400mm Stand complete with shelf, Suits RCB4 Counter-Top models 1
RCSTD6 600mm Stand complete with shelf, Suits RCB6 Counter-Top models 1
RCSTD9 900mm Stand complete with shelf, Suits RCB9 Counter-Top models 1
THSP-B05002 Adjustable legs for RCT Counter-Top mounting only 4
432018-900HK 900mm 3/4” flexible gas hose with quick connect fittings & restraint
1
432018-1200HK 1200mm 3/4” flexible gas hose with quick connect fittings & restraint
RCB4 RCB6 RCB9 RCB9 Shown

Trueheat RCB Infrared Gas Broiler—September 2017 Page 8 of 16
SPECIFICATIONS (cont’d)
GAS CONFIGURATION
Note: When checking gas pressure, ensure that all other equipment on the same
line is turned “ON”.
NOMINAL GAS CONSUMPTION
TO BE COMPLETED BY AN AUTHORISED PERSON.
ONLY CONNECT THE APPLIANCE TO THE GAS TYPE IT HAS
BEEN CONFIGURED FOR. THE GAS TYPE IS SPECIFIED ON
THE DATA PLATE AND AT THE REAR OF THE APPLIANCE.
DESCRIPTION NATURAL GAS PROPANE GAS
Minimum Gas Inlet Pressure 1.13 kPa 2.75 kPa
Test Point Pressure 1.00 kPa 2.50 kPa
Main Injector 1.89 mm 1.13 mm
Pilot Orifice Size 21 Size 14
Low Flame Adjustment 3 turns out from fully in 3 turns out from fully in
Commissioning
Procedure
- Regulator Adjustment
Set the gas pressure at
the main gas valve
while the burner is
running.
Set the gas pressure
at the main gas valve
while the burner is
running.
MODELS NATURAL GAS PROPANE GAS
RCB4 33 MJ/h 30 MJ/h
RCB6 66 MJ/h 60 MJ/h
RCB9 99 MJ/h 90 MJ/h

Trueheat RCB Infrared Gas Broiler—September 2017 Page 9 of 16
INSTALLATION
Note: Installation is the responsibility of the owner.
GAS INLET CONNECTION
3/4” BSP Female.
GAS CONNECTION POINT
The gas connection point is located at the
bottom rear of the Broiler as shown in the
diagram on the right.
GAS CONNECTION
The appliance must be connected by an authorised person to the gas type specified on
the unit. The gas type is shown adjacent to the rear gas connection point and on the data
plate. Only connect to and use the specified gas type that the Broiler has been set for.
Do not remove or modify any of the gas piping within the Broiler. The gas connection must
be made at the connection point provided.
Removal or modification of the gas piping within the Broiler will void the gas certification &
manufacturer’s warranty. This may also affect the customer’s insurance policy.
The authorised person installing this equipment must comply with AS 5601
requirements. Prescribed requirements include, commission the equipment, gas
leakage testing, operational checking and adjustments.
All units are tested and adjusted at the factory; however, burners and pilots must be checked at the
installed location and adjusted if necessary.
THIS EQUIPMENT MUST BE INSTALLED BY AN AUTHORIZED
PERSON IN ACCORDANCE WITH AS 5601, LOCAL AUTHORITY,
GAS, ELECTRICITY, ANY APPLICABLE STATUTORY
REGULATIONS AND MANUFACTURER REQUIREMENTS.

Trueheat RCB Infrared Gas Broiler—September 2017 Page 10 of 16
INSTALLATION ON STAND
The Broiler can be installed on a stand. The Broiler is positively
located on the stand by inserting four bolts from the underside of the
stand into nutserts in the Broiler.
WARNING: Ensure the Broiler is fastened to the stand.
Adjustable feet are included on the leg stands and
allow the unit to be levelled to the floor in the installed
location. Stands with Castors are also available
option.
INSTALLATION ON COUNTER TOP
The Broiler can be installed on a non-combustible
counter top or refrigerated cabinet with optional
100mm adjustable counter top legs. It is
recommended that the appliance is secured to the
counter to prevent unintended movement
INSTALLATION CLEARANCES
The MINIMUM clearance from combustible surfaces is
150 mm rear and 250mm on either side. See diagram
below.
Adequate clearance must also be provided for service.
LEVELLING
To adjust the legs to level the unit to the floor and/or to slightly adjust the height of the unit,
raise the front of the unit and adjust the legs (ensure safe work practices). Similarly, raise the
back and adjust the legs.
DO NOT LAY THE UNIT ON ITS BACK. ENSURE THE UNIT IS LEVELLED.