Gas Pasta Cooker
INSTALLATION & OPERATION MANUAL
RCP4

Trueheat RCP IO Manual—August 2018 Page 2 of 18
CONGRATULATIONS!
Thank you for choosing Trueheat.
This product has been specifically designed by Comcater to meet a wide range of applications
and represents the best quality and highest value equipment.
Please read the Instruction Manual carefully to ensure the safe and reliable operation and
performance of your equipment.
Should you require service, you will be supported by Comcater’s trained and qualified service
network.
COMCATER AUSTRALIA
www.comcater.com.au
National Head Office
156 Swann Drive, Derrimut, VIC 3030
Phone: 03 8369 4600
Fax: 03 8369 4699
Email: sales@comcater.com.au
Technical Services Group
Phone: 1800 810 161
Fax: 03 8369 4696
Email:
Equipment Servicing (24/7)
service@comcater.com.au
Equipment Spare Parts
spares@comcater.com.au
Technical Support
techsupport@comcater.com.au
Comcater QR Codes
Comcater Website Log a Service Call Online Spare Parts Store
Reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorised in writing by Comcater. Comcater reserves the
right to change design and specifications without prior notice. © Copyright Comcater Pty Ltd, August 2017.

Trueheat RCP IO Manual—August 2018 Page 3 of 18
TABLE OF CONTENTS
INTRODUCTION
Warranty...........................................................................................................................4
Date Plate Location ..........................................................................................................4
WARNINGS................................................................................................................................ 5
GENERAL INFORMATION .........................................................................................................6
SPECIFICATIONS
Dimensions, Weight & Installation Drawings.................................................................... 7
Accessories & Optional Accessories ............................................................................... 7
Gas Configuration ........................................................................................................... 8
INSTALLATION
Gas Connection .............................................................................................................. 11
Installation Clearances ................................................................................................... 11
Levelling .......................................................................................................................... 11
CONVERSION INSTRUCTIONS ................................................................................................12
COMMISSIONING / BURNER ADJUSTMENT
Leak Test ....................................................................................................................... 12
Test Point Pressure ........................................................................................................ 12
Pilot Adjustment ............................................................................................................. 12
Target Adjustment .......................................................................................................... 12
OPERATION
First Time Use ................................................................................................................13
Daily Operation ...............................................................................................................13
MAINTENANCE
Daily Cleaning ................................................................................................................14
Recommended Service Plan .......................................................................................... 15
TROUBLESHOOTING
Burner will not light .........................................................................................................16
Pilot not lighting ..............................................................................................................16

Trueheat RCP IO Manual—August 2018 Page 4 of 18
INTRODUCTION
GENERAL
The Trueheat RC Series is designed for commercial catering purposes only and incorporates a
wide range of design features. It is designed to deliver high-end performance to fulfill the busy
demands within a commercial kitchen. It is available in various appliances and configurations
including:
Ranges with open burners, griddles with oven or as Counter-Top unit.
Broilers, salamanders, pasta cookers and deep fryers.
This versatility will satisfy a wide range of customer needs.
WARRANTY
12 months replacement of parts including labour, for goods found to be faulty due to defective
materials, manufacture and/or workmanship. This warranty is void if installation, operation and/or
maintenance of the equipment are not in accordance with manufacturer’s instructions and
recommendations.
Unauthorised modifications to the equipment will void the warranty and product certification.
All warranty work will be undertaken in normal working hours from Monday – Friday 8:00am to
4:00pm
Warranty does not extend to:
Damages caused in shipment
Damage as a result of incorrect installation
Damage as a result of incorrect operation
Damages caused by Unauthorised service and use of non-original parts
Gas supply issues to the equipment
Calibration of thermostats after 90 days
Failure resulting from improper maintenance
Failure as a result of tampering with, removal of, or changing any pre-set control or
safety device
After hours Service - Penalty rates apply for afterhours service.
Conditions as defined in Comcater terms and condition of sale, a copy of Comcater’s terms and
conditions of sale can be found at www.comcater.com.au/terms
For all warranty work, authorized service, genuine and authorized spare parts, please contact
Comcater Service 1800 810 161.
Please ensure you quote the Model and Serial Number of the unit.
The Model and Serial Number of the unit is recorded on the sales invoice, and also shown on
the top right side of the front control panel. The data plate is located behind the front control
panel.

Trueheat RCP IO Manual—August 2018 Page 5 of 18
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY OR DEATH. THE
INSTRUCTION MANUAL MUST BE READ CAREFULLY BEFORE
INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
TO BE INSTALLED ONLY BY AN AUTHORISED PERSON IN
ACCORDANCE WITH AS/NZS 5601.1, LOCAL AUTHORITY, GAS,
ELECTRICITY, ANY APPLICABLE STATUTORY REGULATIONS AND
MANUFACTURER REQUIREMENTS.
THIS EQUIPMENT IS DESIGNED FOR COMMERCIAL CATERING
PURPOSES AND WILL GENERATE SIGNIFICANT HEAT. HOT
SURFACES WILL CAUSE BURNS. A HAZARD AND RISK
ASSESSMENT MUST BE UNDERTAKEN BY OWNERS AND ALL
OPERATORS MADE AWARE OF THESE.
DO NOT STORE OR USE FLAMMABLE LIQUIDS NEAR THIS
APPLIANCE.
DO NOT SPRAY AEROSOLS NEAR THIS APPLIANCE WHILE IT IS IN
OPERATION.
INSTALLATION CLEARANCES AS SPECIFIED MUST BE OBSERVED.
IF YOU SMELL GAS, TURN THE UNIT OFF AND THE MAIN GAS
SUPPLY VALVE TO THE UNIT. CONTACT YOUR GAS SUPPLIER OR
AN AUTHORISED PERSON.
BEFORE TURNING ON THE MAIN GAS SUPPLY, CHECK THE UNIT TO
BE CERTAIN THAT ALL THE VALVES ARE IN THE “OFF” POSITION.
WARNINGS

Trueheat RCP IO Manual—August 2018 Page 6 of 18
GENERAL INFORMATION
INSPECTION
Please inspect the unit on receipt. If the unit is damaged, contact the carrier immediately and le a
damage claim with them. Save all packing materials when ling a claim. Freight damage claims are the
responsibility of the purchaser and are not covered under warranty.
OPERATOR MANUAL
This manual contains important informaon for your safety and the installaon, operaon,
maintenance and service of this equipment. Please read the manual carefully and ensure all
operators of the equipment are aware of the contents and safety requirements. You must also
assess all hazards and risks associated with the operaon of the equipment in your environment and
advise all operators of these.
INSTALLATION
This equipment must be installed by an authorized person in accordance with AS/NZS 5601.1, local
authority, gas, electricity, any applicable statutory regulaons and manufacturer requirements.
GAS CONNECTION
The appliance must be connected by an authorized person to the gas type specied on the unit. The
gas type is shown adjacent to the rear gas connecon point and on the data plate. Connect to and
use only the correct type of gas.
GAS PRESSURE
The authorized person installing this equipment must ensure that the gas operang pressure is the same as
shown on the rang plate and that there is sucient gas volume for the appliance to operator correctly.
COMMISSIONING
The authorized person installing this equipment must commission the equipment in accordance with AS/NZS
5601.1 - gas leakage, operaonal checking, adjustments and instrucng the owner on use of the equipment
are prescribed requirements.

Trueheat RCP IO Manual—August 2018 Page 7 of 18
SPECIFICATIONS
DIMENSIONS, & INSTALLATION DRAWINGS, OPTIONAL ACESSORIES
The following tables and drawings provide all dimension, weight and optional accessories.
IMAGE PART NO. DESCRIPTION *QTY
S45069 Additional Basket Set with Wireframe 1
B21273 Medium Basket 280L X 145W X 180H 1
S35041 Noodle Basket Set with Stainless Steel Frame 1
8100357 Front Castors Swivel with brake 2
8100378 Rear Castors Fixed without brake 2
COM-WF0116 1500mm SS braided water hose 3/4” female & 1/2” female 1
432018-900HK 900mm 3/4” flexible gas hose with quick connect fittings & restraint
1
432018-1200HK 1200mm 3/4” flexible gas hose with quick connect fittings & restraint
DIMENSIONS
Width (mm) 400
Depth (mm) 803
Height (mm) 1135
OPTIONAL ACCESSORIES
*QTY = Quanty required per unit.

Trueheat RCP IO Manual—August 2018 Page 8 of 18
SPECIFICATIONS (cont’d)
GAS CONFIGURATION
NOTES:
1. When checking gas pressure, ensure that all other equipment on the same line is
turned “ON”.
2. Values shown are those measured at the manifold pressure test point.
TO BE COMPLETED BY AN AUTHORISED PERSON.
ONLY CONNECT THE APPLIANCE TO THE GAS TYPE IT HAS
BEEN CONFIGURED FOR. THE GAS TYPE IS SPECIFIED ON
THE DATA PLATE AND AT THE REAR OF THE APPLIANCE.
NATURAL GAS PROPANE GAS
Minimum Gas Inlet Pressure 1.13 kPa 2.75 kPa
Test Point Pressure 1.00 kPa 2.50 kPa
Descripon NATURAL GAS PROPANE GAS
Minimum Inlet Pressure 1.13 kPa 2.75 kPa
Test Point Pressure 1.00 kPa 2.50 kPa
Gas Consumpon 40 MJ/h 40MJ/h
Main Injector 3.00 mm 1.8 mm
Pilot Orice (marking) Adjustable Orifice (35) Adjustable Orifice (35)
Pilot Adjustment 3/4 turn out from fully in Fully in
Low Flame Adjustment 3 turns out from fully in 3 turns out from fully in

Trueheat RCP IO Manual—August 2018 Page 9 of 18
INSTALLATION
Note: Installation is the responsibility of the owner.
WATER INLET CONNECTION
1/2” BSP Male
GAS INLET CONNECTION
1/2” BSP Female.
GAS CONNECTION POINT
The gas connection point is located lower
at the rear of the appliance.
GAS CONNECTION
The appliance must be connected by an authorised person to the gas type specified on
the unit. The gas type is shown adjacent to the rear gas connection point and on the data
plate. Only connect to and use the specified gas type that the appliance has been set for.
Do not remove or modify any of the gas piping within the appliance. The gas connection
must be made at the connection point provided.
Removal or modification of the gas piping within the appliance will void the gas
certification & manufacturer’s warranty. This may also affect the customer’s insurance
policy.
The authorised person installing this equipment must comply with AS/NZS 5601.1
requirements. Prescribed requirements include, commission the equipment, gas
leakage testing, operational checking and adjustments.
All units are tested and adjusted at the factory; however, burners and pilots must be checked at the
installed location and adjusted if necessary.
THIS EQUIPMENT MUST BE INSTALLED BY AN AUTHORIZED
PERSON IN ACCORDANCE WITH AS/NZS 5601.1, LOCAL
AUTHORITY, GAS, ELECTRICITY, ANY APPLICABLE STATUTORY
REGULATIONS AND MANUFACTURER REQUIREMENTS.

Trueheat RCP IO Manual—August 2018 Page 10 of 18
INSTALLATION CLEARANCES
The MINIMUM clearance from combustible surfaces is 150 mm rear
and 150mm on either side. Where castors are used on installations where
combustions are adjacent, ensure that a stand off isolated behind the appliance to
ensure that the customer can reposition the closer than 150mm.
See diagram below.
NOTE:
1. Ensure adequate clearance is provided for service & maintenance.
2. Ensure that the gas regulator is accessible for adjustment
LEVELLING
To adjust the legs to level the unit to the floor and/or to slightly adjust the height of the unit,
raise the front of the unit and adjust the legs (ensure safe work practices). Similarly, raise the
back and adjust the legs.
Castors are non-adjustable and should only be used when are floors level.
DO NOT LAY THE UNIT ON ITS BACK. ENSURE THE UNIT IS LEVELLED.
Inhaltsverzeichnis
Beliebte Nudelmaschine Handbücher anderer Marken

Emeril Lagasse
Emeril Lagasse Pasta & Beyond Bedienungsanleitung

Imperia
Imperia PASTA PRESTO NSP Handbuch

DAY
DAY 74048 Bedienungsanleitung

Marcato
Marcato Ampia Wellness Technisches Datenblatt

Philips
Philips HR2354/12 Bedienungsanleitung

Electrolux
Electrolux Electric Pasta Cookers 700XP Bedienungsanleitung

Keating Of Chicago
Keating Of Chicago Custom Pasta Gas System 0107 Bedienungsanleitung

Viante
Viante CUC-26PM Bedienungsanleitung

Emeril Lagasse
Emeril Lagasse Pasta & Beyond PM-01 Bedienungsanleitung

Omcan
Omcan PM-IT-0080 Bedienungsanleitung

KitchenAid
KitchenAid KSMPEXTA Bedienungsanleitung

Weston
Weston 01-0201 Bedienungsanleitung