8GB TKF 104 - 1 E254en1_02.doc
Maintenance
Danger of injury
Always disconnect the compressed-air
tube from the machine before beginning
any work on the machine!
Cutting tool guide l u b r i c a t i o n
•after 50 meters have been cut
•after each tool change
Original grease: Lubricating grease " S1" tube
TRUMPF order no. 121486
See Fig. 14194 (next page)
Gear/gear head l u b r i c a t i o n
Gear grease must be refilled or changed after repairs
but no later, however, than after 300 hours of
operation.
Original grease: Lubricating grease "G1"
TRUMPF order no. 139440
Alternative greases: BLASER BLASOLUBE 308
BP Energrease HTB2
FUCHS Renoplex EP 1
MOBIL Mobiltemp SHC 32
Compressed-air motor l u b r i c a t i o n
Damage to property
Lubrication of the compressed-air motor
is very important. The motor will fail if it
is operated without lubrication even for a
short time.
There are two ways to check that the compressed-air
motor is properly lubricated:
1. For short operating times or varying operating
sites via the internal oil chamber.
See Fig. 11425
•You must ensure that the oil level in the oil
chamber is sufficient before each use.
Lubricating interval: approx. 1 operating hour
•Oil is refilled through the opening in the
sealing screw, screw-plug (313).
•Ensure that the oil level is not too high.
2. It is receommended that an oil mist
lubricating device (e.g. Atlas Copco DIM
25) be installed in the compressed-air line for
continuous operation.
Checking the oil supply of the motor
Hold a piece of paper in front of the exhaust opening
in the motor housing while the machine is running.
The oil supply is sufficient if oil stains form.
Recommended oils (compressed-air motor
lubrication):
•BP Energol RD 80 (-15 to +10° C),
•BP Energol RD-E80 (+10 to +30° C),
•Shell Tellus Oil 15 (-15 to +10° C),
•Torculla 33 (+10 to +30° C).
Motor bearing l u b r i c a t i o n
The ball bearing in the motor flange is to be lubricated
via the lubricating head using a grease gun.
See Fig. 11425
Lubricating interval: every 10 operating hours
Recommended
greases:
BP Energrease LS-EP 2
SHELL Alvania Grease EP 2
Fig. 11425
312 Lubricating head for motor bearing lubrication
313 Sealing screw of oil filler neck
314 O-ring (9.2 x 1.8) under the sealing screw
355 Filter
358 Quick-release coupling
M center machine axle
max.Maximum oil level when refilling oil (15 mm
under the filler neck when the center axle is
horizontal)
Note: If the oil level is too high, oil will spill out
of the motor housing exhaust opening
355
312 max. 15mm
313
314 M 358