Truth Hardware Sentry II WLS Bedienungsanleitung

Danger: To help prevent severe personal injury or death:
oRead and understand instructions completely before beginning
installation.
oWhen connecting the Sentry 2 system to accessories, read the
installation instructions supplied with each accessory before
beginning installation.
oSave ALL instructions.
oInstaller – please be sure to give ALL instructions to the
homeowner once installation is complete.
oWiring must be installed by a qualified electrician according to local
and National Electrical Codes (N.E.C.)
oDisconnect main power before beginning installation! Verify that
power is OFF at the main breaker or fuse panel by testing with a
voltage meter that you know is working correctly.
oConnect power only after motor connections and settings are
verified.
oThis equipment does not provide a method to shut off power, and
should be connected to a dedicated breaker or fused power circuit
capable of providing 50 watts of power per control.
oThe Sentry 2 system must not be used on windows intended to
meet egress codes.
oThe Sentry 2 system is intended for indoor use only, with screens in
place.
oThe screen interlock MUST be correctly mounted and is a required
part of the installation on windows/skylights less than 8 ft from the
floor. It is intended to help prevent injury that could result from
reaching into the window or skylight opening during operation.
oDo not allow children to operate the wall push buttons or remote
control transmitter(s).
LANGUAGES
ENGLISH PAGE 1
FRANÇAIS PAGE 39
Made in USA
An FKI Industries Company
700 West Bridge Street
Owatonna, MN 55060
1-800-324-4487
www.truth.com
Form 90063 R1
Window or Li
g
ht Skyli
g
ht
Motorization System
Installation Instructions
Sentry II WLS®
ESPAÑOL PAGINA 20

2
Battery Backup
Battery backup should be used to supply emergency power for
those areas subject to frequent power outages or when operation
of the power window system must be maintained for a period of
time should a power outage occur.
Truth recommends the use of a UPS (uninterruptable power
supply) as a battery backup. They are widely available through a
variety of retail and commercial outlets and are primarily used to
supply emergency backup for computer equipment.
To determine the proper VA rating for a UPS, take 50 watts and multiply by
the number of windows/skylights to be backed up by a given UPS.
Below is a list of the manufacturers who produce uninterruptable
power supplies which we have approved as compatible with
our power window systems.
Best Power Technology Inc.
P.O. Box 280
Necedah, WI 54646
(800) 356-5794
(608) 565-7200
www.bestpower.com
American Power Conversion
132 Fairgrounds Road
West Kingston, RI 02892
(800) 788-2208
(401) 789-5735
www.apcc.com
Tripp Lite
1111 West 35th Street
Chicago, IL 60609
(773) 869-1111
www.tripplite.com
Minuteman (brand)
1455 LeMay Drive
Carrollton, TX 75007
(800) 238-7272
(972) 446-7363
www.minuteman-ups.com
Powerware
Forum III
8609 Six Forks Road
Raleigh, NC 27615
(800) 554-3448
(919) 872-3020
www.powerware.com

3
1a. Windows
The window must operate correctly and smoothly. Lubrication or cleaning of
hardware may be required. This motor system will not operate correctly if the window/skylights
manual hardware is not functioning properly.
Note the direction of rotation for crank to open the window as either Clockwise or Counter
Clockwise (when facing the window operator)
Circle the direction to OPEN: COUNTER-CLOCKWISE CLOCKWISE
1b. Skylights
The skylight lid must weight less than 80 lbs. (40 lbs. at the chain).
A hand crank should be used to verify the skylight operates smoothly.
Lubrication, cleaning or re-alignment of hardware may be required.
Must weigh less
than 40lb (18 kg)

4
2. Install Adapter
Install the spline adapter (B) onto operator shaft and tighten set screw with wrench (A).
3a. Mount Motor to Window
Install motor by slipping it over the spline adapter (B) as shown. Secure motor with bracket (C).
A number of mounting positions are provided by the bracket, use the one which provides the best
alignment with the window frame. Be sure to use both the isolation grommet (D) and the push-on
fastener (E). Due to the high torque of the motor, two screws should be used when mounting the
bracket (C) to wood or plastic window frames.
A
B

5
3b. Mount Motor to Skylight
Install motor by slipping it over the spline adapter (B) as shown. Secure motor with bracket (C)
using the appropriate screw. Be sure to use both the isolation grommet (D) and the push-on
fastener (E).
4. Align & Tighten Collar
Align motor to window or skylight and tighten set screw in black
plastic alignment collar (F) with wench (A). Do Not Over Tighten
B
A

6
5. Install Screen Interlock!
Install screen interlock (G) as shown using pan head screw (H)
supplied.
WARNING: The screen interlock must be correctly installed on windows or skylights less than 8 ft
from the floor. It is intended to prevent personal injury and/or window damage during operation.
On vents above 8 ft a jumper wire (included) is installed into the Grey terminals of block 10.
6. Secure Wires & Install Cover
Connect motor wires per wire diagram and secure with tape. Install the motor cover using the
6X3/8 PH screw (K) found under cover button (J).
*WARNING: Use of a longer screw will damage motor.
K*

7
7a. Prepare Wall Opening (with finished wall)
Locate the desired mounting location for the wall control unit. Verify the location of interior wall
studs before selecting the mounting orientation of control box. Using the template provided, mark
and cut the prescribed hole for the selected orientation.
7b. Prepare Wall Mount (with open wall)
Locate the desired mounting location for the wall control unit. Mount control box onto the selected
wall stud with screws (not included) at the desired height. Using the template provided, mark and
cut the prescribed hole in wall board for the intended application.
8. Route and Install wires
Route low voltage wires from motor location (including any accessory wires, such as rain sensor,
power blind, etc..) into control switch opening. Route appropriate high voltage wire and select an
inlet on control box which works with the selected orientation. Remove knock-out and install strain
relief provided. Pull 110vac wiring into control box through strain relief.
WARNING: Power supplied to high voltage (110 vac) wiring should be disconnected at Main
Breaker Panel or through other means. This motor control will need approx. 50 watts of power.
NOTE: Installation must meet local and national electrical codes.
Refer to Wire Diagram for wire size and type.
Use template to mark
cutout location and
cut as required.
Break off
tabs (4)
Strain
Relief

8
9. Install Control box (with finished wall)
Using Template on back of this instruction booklet, mark and cut wall opening. (Cutout size is 3
7/8 inches Wide X 4 1/8 inches High) Note that a portion of the wall box is hidden inside the wall
cavity, and that the box and wall plate can be mounted in any direction required.
When the box is installed after the wall is finished (enclosed) the mounting wings should be
broken off and discarded. The wall clamps engage the wall automatically as the screws are
tightened.
Insert control box into wall opening. Secure box to wall by tightening clamp screws. Route wire
groups appropriately: Low voltage wires from window/skylight through the notch found on the
control side of box.
Clamp
screws
Cut off
mounting
wings
Wall box
installed.
High
Voltage
Wires Low
voltage
wires

9
10. Connect Wires Per Wire Diagram
Connect low voltage wires to the control panel as outlined in wire diagram.
See Connection Blocks 1 thru 5.
11. Set Function Dip Switches
The Function Settings on Dip Switch (See S2 on wire diagram) need to be configured for each
motor application.
1
2
34
5
6
on
off
1 – Must stay set to “on”
2 – Motor Application:
Window = “off”
Skylight=“on”
3 – Drive motor direction to open from Step 1a
CW = “off” OR CCW = “on”
4 – Motorized Blinds:
No Blind present = “off”
Blind connected = “on”
5 & 6 – Motorized Locks
No Locks = 5 & 6 both “off”
One Lock = 6 “on” & 5 “off”
Two Locks = 6 “off” & 5 “on”
Note: Dip switch settings should be made with Power disconnected.

Grey
Green
Grey
Grey
Grey
Green
Green
Green
White
White
White
Grey
Grey
Red
Black
Blue
Blue
Blue
12
10
7
5
4
Motor
Lock 1
Lock 2 Red
Black
Red
Black
Screen
Interlock
Red
Black
Black
Black
Jumper
supplied
in kit
See Step 5
+
-Blind motor
Security System
Close Command Status
+
-+
-
S2
S1
1
2
34
5
6
on
off
Smoke Vent Control
J1
Open Command
Rain Sensor
White
White S2
1
2
34
5
6
on
off
1 - Must stay set to "on"
2 - Motor Application:
Window application = "off"
Skylight application = "on"
3- Drive motor direction to Open:
CW ="off" Or CCW = "on"
4- Motorized Blind:
No Blind present = "off"
Blind connected = "on"
5&6 - Motorized lock s :
No locks = 5 & 6 both "off"
One lock = 6 "on" & 5 "off"
Two locks = 6 "off" & 5 "on"
Function Settings for Dip Switches:
Wire Size
(Class 2)
Total distance
from Control to
farthest motor
18 AWG
14 AWG
12 AWG
50 ft (15m) Max.
100 ft (30m) Max.
150 ft (60m) Max.
Solid Core Wire Recommended.
Refer to Class 2 codes
Earth Ground for accessories
Main Wiring Diagram
Inhaltsverzeichnis
Beliebte Fernbedienung Handbücher anderer Marken

Panasonic
Panasonic EUR7622KB0 Bedienungsanleitung

Bang & Olufsen
Bang & Olufsen Beo4 Bedienungsanleitung

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Bedienungsanleitung

Multiplex
Multiplex PROFI TX 9 Bedienungsanleitung

One Remote
One Remote RMB4 Bedienungsanleitung

FUTABA
FUTABA 9ZAP - PART2 Bedienungsanleitung











