TYROLIT Hydrostress DME24MW Series Bedienungsanleitung

Operating Instructions
DME24MW / DME24UW
Index 003
Original operating Instructions
10995607 en / 03.03.2016
DME24MW
DME24UW

Page 2 DME24MW / DME24UW
TYROLIT Hydrostress AG
Witzbergstrasse 18
CH-8330 Pfäkon
Switzerland
Tel. 0041 (0) 44 952 18 18
Fax 0041 (0) 44 952 18 00
Congratulations!
With a Hydrostress unit from TYROLIT you have chosen a tried and tested piece of equipment
designed and built to the highest technical standards. Only genuine TYROLIT Hydrostress re
-
placement parts can guarantee quality and interchangeability. If maintenance work is neglect
-
ed or carried out inexpertly we will be unable to honour our warranty obligations. Any repair
work must be carried out by trained personnel only.
Our after-sales service is available to help ensure that your TYROLIT Hydrostress units remain in
perfect working order.
We hope that working with your TYROLIT unit will be a satisfying and fault-free experience.
TYROLIT Hydrostress
Copyright © TYROLIT Hydrostress

TYROLIT Hydrostress AG
Page 3
DME24MW / DME24UW
Table of contents
Page
1. Concerning these instructions .................................................... 4
2. Safety ........................................................................... 5
3. Product description .............................................................. 8
4. Design and Function.............................................................. 11
5. Assembly / Disassembly .......................................................... 13
6. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7. Servicing and Maintenance ....................................................... 17
8. EC Declaration of Conformity ..................................................... 18

TYROLIT Hydrostress AG
Page 4 DME24MW / DME24UW
Concerning these instructions
These instructions are just one part of the documentation which is supplied together with the
electric tool.
These instructions go together with the“Core Drills Safety Manual / System Description” to form
a complete set of documentation.
These instructions, together with the“Core Drills Safety Manual / System Description”, are a con-
stituent of the equipment. They describe how to use the equipment safely and properly in all
phases of operation.
• Read the instructions carefully before use, particularly the safety instructions.
• Keep the instructions for the entire service life of the equipment.
• Ensure that the instructions are available to the operator and the service engineers at all
times.
• Pass the instructions on to all subsequent owners or users of the equipment.
• Update instructions with all supplements received from the manufacturer.
Symbols in these instructions
DANGER
Warning of danger, where failure to comply could lead to death or serious injury.
WARNING
Warning of danger, where failure to comply could lead to injuries or damage to property.
WARNING
Warning - dangerous electrical voltage.
Before working in an area identied in this way, the installation or device must be fully discon-
nected from the power (voltage) and secured against being accidentally powered up again.
INFORMATION
Information for optimum use of equipment. Failure to take note of this information may mean
that the performance information shown in the technical data can no longer be guaranteed.
RECYCLING
Take waste for recycling.
DISPOSAL
The normal national and regional rules and guidelines must be observed during disposal.
1.
1.1

TYROLIT Hydrostress AG
Page 5
DME24MW / DME24UW
Safety
Core drilling systems may only be operated by authorised persons. Information about author-
ised persons can be found in the“Core Drills Safety Manual / System Description”.
Protective devices and signs on the equipment
Protective devices
Protective devices may only be removed if the equipment has been switched o, disconnected
from the mains and is at a standstill. Safety components in particular should only be removed
and retted by authorised personnel.
Before switching the equipment back on again, check that the safety elements are operating
correctly.
Signs on the equipment
Safety sign
1 Wear safety shoes 3 Wear a breathing mask 5 Read the instructions
2 Wear gloves 4 Wear a helmet, goggles and
hearing protection 6 Before working on the equipment
unplug mains
Name plate
Safety clothing
Anyone working with and on core drilling systems is strictly required to wear individual protec-
tive equipment.
Safety clothing
Safety clothing
Spare parts and modications
Only original spare parts from TYROLIT Hydrostress must be used. Otherwise damage may be
caused to the equipment or to other property and persons. No additions or modications must
be made to the equipment without written permission from TYROLIT Hydrostress.
2.
2.1
2.1.1
CH-8330 Pfäffi kon ZH
DME24UW
2300 W 13A
50-60 Hz 230 V 1~ RPM
Ømax.
2.1.2
2.2

TYROLIT Hydrostress AG
Page 6 DME24MW / DME24UW
Danger and working area
Danger zone at electrical tool
The marked area on the drawing denes the danger zone of the electrical and cutting tool.
The minimum clearance of 15 cm must be maintained during operation.
Danger zone at electrical tool
Danger zone at workplace
Information about the danger zone at the workplace can be found in the“Core Drills Safety
Manual / System Manual”.
Product-specic dangers
Personal protection device (PRDC, GFCI)
Only ever work if a serviceable current-operated personal protection device is present (PRCD,
GFCI).
Personal protection device
DANGER
Failure to comply will result in a risk of death or serious injuries
XKeep your electrical tool away from rain and moisture. Water penetrating an electrical tool
increases the risk of electric shocks.
Overhead drilling
XOverhead drilling is not permitted in wet conditions.
2.3
2.3.1
2.3.2
2.4
2.4.1
2.4.2

TYROLIT Hydrostress AG
Page 7
DME24MW / DME24UW
Residual risks
Risk of serious injuries from the residual risks described in the chapters that follow.
Diamond segments ying o
XDo not start drilling if any other persons are in the danger zone.
XEnsure that a safety distance is maintained.
XReplace the diamond drill bit is diamond segments start to break o.
Uncontrolled movements and vibration
XNever connect or disconnect cables during operation..
Catching and winding in
Items of clothing or long hair can be caught by the rotating cutting tool.
XDo not wear loose items of clothing at work.
XWear a hair net if you have long hair.
Damaging vapours and aerosols
Inhaling damaging vapours and/or aerosols can cause breathing problems.
Breathing in the water fog that is created is a health hazard.
XWear a breathing mask.
XProvide adequate ventilation in conned spaces.
Physical condition
XDo not work whilst under the inuence of alcohol, drugs or medication.
XDo not work when you are overtired.
Cutting tool quality
XDo not use damaged cutting tools.
XCheck cutting tool for damage before installation.
Risk of cutting tool restart in the event of an accident
XEnsure that the electrical equipment can be stopped quickly.
DANGER
Failure to comply with the safety instructions in the “Safety Manual / System Manual”may result
in serious injury or even death.
XPlease ensure that the“Core Drills Safety Manual / System Description”has been read and
understood in full.
2.5
2.5.1
2.5.2
2.5.3
2.5.4
2.5.5
2.5.6
2.5.8

TYROLIT Hydrostress AG
Page 8 DME24MW / DME24UW
Product description
Core drilling system
1 Electrical tool 3 Drill rig
2 Cutting tool 4 Fastening elements
Core drilling system
This electrical tool forms a core drilling system in conjunction with suitable TYROLIT
Hydrostress components.
Use for correct purpose
The DME 24MW und DME 24UW electrical tools are intended for stand-controlled
wet drilling into mineral subsurfaces using diamond drill bits no manual operation). During
operation a suitable drilling stand must be used and sucient anchoring to the subsurface pro-
vided using dowels, a vacuum plate or a quick clamping support..
Manipulation or modications to the equipment, the drilling stand or the accessories are not
permitted. Always use original TYROLIT Hydrostress accessories and suitable tools during use in
order to prevent injuries.
Scope of supply
• Drill motor
• WAF32 / WAF22 tool wrenches
• Water line adapter
3.
3.1
3.2
3.3

TYROLIT Hydrostress AG
Page 9
DME24MW / DME24UW
Technical data and main dimensions
Technical data
Drill motor DME24MW DME24UW
Nominal voltage 230 V 110 V 230 V 110 V
Frequency 50 Hz 60 Hz 50 Hz 60 Hz
Drill diameter range 40 - 250 mm
Nominal power 2.2 kW
Nominal current 10 A 20 A 10 A 20 A
On-load speed 370/590/990 rpm
Idle speed 710/1130/1900 rpm
Engine cooling Air
Tool tting (external) 1¼“ UNC
Tool tting (internal) G ½“
Operation drill rig-controlled
Application wet
Electronic overload protection Yes
Mechanical overload protection Yes
PRCD protective switch Yes
Power display Yes
Service indicator Yes
Drill stand holder ModullDrillTM Universal plate
Weight 7.6 kg 7.7 kg
Noise emission
Noise data according to ISO 3744
Parameter Value
Sound pressure level L pA 78.9 dB (A) *
Maximum sound pressure level L pCpeak 106.8 dB (A)
Sound power level LWA 98.9 dB (A) *
Conditions for the measurement:
* Without cutting tool Ø200 mm in operation
3.4
3.4.1

TYROLIT Hydrostress AG
Page 10 DME24MW / DME24UW
Measurements
Measurements in mm
Lubricants, uids
Lubricants, uids and sealants
Parameter Value
Gear oil ISO 100 (TYROLIT No. 10996358/350ml)
Name plate
The type designation and serial number are marked on the name plate of your electrical tool.
Name plate
3.4.2
3.7
3.8
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Andere TYROLIT Hydrostress Elektrowerkzeuge Handbücher

TYROLIT Hydrostress
TYROLIT Hydrostress HGE125 Bedienungsanleitung

TYROLIT Hydrostress
TYROLIT Hydrostress DME20PW Series Bedienungsanleitung

TYROLIT Hydrostress
TYROLIT Hydrostress / DME24UW Series Bedienungsanleitung

TYROLIT Hydrostress
TYROLIT Hydrostress HCE150 Bedienungsanleitung

TYROLIT Hydrostress
TYROLIT Hydrostress WSE1621 Bedienungsanleitung

TYROLIT Hydrostress
TYROLIT Hydrostress DME38UW Bedienungsanleitung

TYROLIT Hydrostress
TYROLIT Hydrostress DME19DPP Handbuch