UlalaLAB WFS-205BW Bedienungsanleitung

1
WICON
WFS-205BW
[IIoT WiFi Gateway]
USER MANUAL
FCC ID: 2AO6A-WFS-205BW

2
RF Exposure “This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled envi-ronment. This equipment should be installed and operated with minimum
distance 20cm be-tween the radiator and your body. This transmitter must not be co-located or
operating in con-junction with any other antenna or transmitter.”

3
Contents
1. Summary ................................................................................................................................................................................4
1.1 System summary .....................................................................................................................................................4
1.2. Device specification ..............................................................................................................................................5
1.3 Sensor input specification ...................................................................................................................................5
1.4 Device order number- example ........................................................................................................................5
2. Product outline ....................................................................................................................................................................6
2.1 View ..............................................................................................................................................................................6
2.2 Size (unit : mm) .......................................................................................................................................................6
3. Device detail description .................................................................................................................................................7
3.1 Power port .................................................................................................................................................................7
3.1 LED ................................................................................................................................................................................7
3.3 Reset button .............................................................................................................................................................8
3.4 Sensor connector ....................................................................................................................................................8
4. Sensor wiring example .....................................................................................................................................................9
4.1 Thermocouple sensor wiring (only K-type) .................................................................................................9
4.2 Analog input wiring ( volt, current, resistance ) ........................................................................................9
4.3 Digital input wiring ............................................................................................................................................. 10
5. WICON Setting ................................................................................................................................................................. 12
5.1 Wicon manager download .............................................................................................................................. 12
5.2 Search device ......................................................................................................................................................... 12
5.3 Serial number ........................................................................................................................................................ 13
5.4 Device information .............................................................................................................................................. 13
5.5 View Wim-X ........................................................................................................................................................... 14

4
1. Summary
1.1 System summary
- This product is for Smart Factory. It collects analog and digital signals and sends
them to the cloud server. Users can analyze sensor data on cloud servers through WIM-
X(trend, alarm, report….). Thus, the improvement of the production quality can be
expected.
The device consists of three modules. (Bluetooth module-for setting, WiFi module-for
transmission, Sensor connection module-for sensor)
The device supports four types of analog input and three types of digital input
(Thermocouple, volt, current, resistance / NPN, PNP, dry contact).
Compared to other company devices, it is compact and easy to install (Settings can be
made using a smartphone). The magnet mounted cradle will make installation
comfortable. This is a good choice when you need to install a small number of sensors.

5
1.2. Device specification
Specification value Remark
Input Voltage USB power supply DC 5V / 1A
Power Consumption 10W Under Except Sensor
Operation temperature -30℃~ 75℃
Processor ARM Cortex-M3 / M4 BLE / Wifi
Clock 48Mhz / 80Mhz BLE / Wifi
RAM 28kByte / 256kByte BLE / Wifi
ROM 128Kbyte / 4Mbyte BLE / Wifi
Bluetooth BLE only 4.0
WiFi 802.11 b/g/n (20Mhz only)
Security WPA
WiFi Max Throughput 13Mbps Application level
WiFi RX Sensitivity –95.7 dBm / –74.0 dBm 1 DSSS / 54 OFDM
Antenna gain Chip antenna 1.9dBi
1.3 Sensor input specification
1.4 Device order number- example
- You should check the order number when ordering the product.
> WFS-205DS-KKKK -> thermocouple (total 4ch)
> WFS-205DS-VXXX -> analog volt input (total 1ch)
> WFS-205DS-VCDX -> analog volt,currnet input, digital input (total 3ch)
Input Type Measurement
Range Remark Order
Number
Analog
Thermocouple
K-type 0~1000℃ +-2℃ Accuracy Range 0~250℃
(within Reference Junction 25~100℃) “K”
Volt 0~10 V 16it Resolution
“V”
Current 0~20 mA 16it Resolution
“C”
Resistance 50~10kΩ Not support 3-wire RTD, But if you want to use it,
short the calibration line and use it. “O”
Digital DC 12~24V 3kv isolation
NPN, PNP, Dry contact “D”
Unused
“X”

6
2. Product outline
2.1 View
- To protect the product, you must use the cradle when using the product.
2.2 Size (unit : mm)
Sensor wiring connector
(Plug type)
WFS-205BW(BLE)
for setting
WFS-205DS
(Sensor Connectino Module)
Cradle that can be
attached to metal
Power connector
(USB Micro 5pin)
WFS-205BW(WiFi)
for communication
77.2
121.
2
50

7
3. Device detail description
3.1 Power port
- Connect the 5V 1A power supply with the enclosed cable.
3.1 LED
- Display device status
Table 1 WFS-205BW(WiFi) RED LED status
LED status Device status Remark
Fast blink AP connection attempt 250msec
Light on AP connection completed
Slow Blink AP connection Fail 1sec
Very Slow Blink Server connection Fail 10sec
- LED status afer power on (Normal setting status)
①WFS-205BW (BLE, WiFi) RED LED on
②WFS-205BW (WiFi) RED LED fast blink ( 250msec )
③WFS-205BW (WiFi) RED LED light on
④WFS-205BW (WiFi) BLUE ELD blink ( every 1sec )
Blinking “BLUE” when sampling
Light on “RED” when power on
See table below
Blinking “BLUE” when communicating

8
3.3 Reset button
- Reset or initialization.( Each click should be within 0.5 seconds.)
> 1 click is device reset.
> 2 click is device hibernation.
> 3 click is device device initialization.
3.4 Sensor connector
- No.1 and No.2 are default. But There are differences between sensor types.
Table 2 Connector pin map
NO TH-K AI-V AI-C AI-O DI-D
1
Thermocouple + Volt (0~10V) Current (0~20mA) Register + DC + (12~24V)
2
Thermocouple - GND GND GND DC -
3
GND GND GND GND GND
4
Reserved Reserved Reserved Reserved Reserved
5
+24V +24V +24V +24V +24V
6
+5V +5V +5V +5V +5V
①
②
③
④
⑤
⑥

9
4. Sensor wiring example
4.1 Thermocouple sensor wiring (only K-type)
- Default port number is 1,2 (No.1 + No.2 –)
- If not connected, the temperature is 1000℃
- You wind the sensor cable 2~3 times to the ferrite core for data reliability and
electromagnetic shielding.
Figure 1 Thermocouple wiring
4.2 Analog input wiring ( volt, current, resistance )
- Default port number is 1,2
- Power supply No.3(GND), No.5(+24V), No.6(+5V)
- You wind the sensor cable 2~3 times to the ferrite core for data reliability and electromagnetic
shielding.
> Example. Voltage output Sensor ( MM2001 Humidity Red:+5V, Black:GND, Yellow:Signal )
Figure 2 Voltage output sensor Example

10
> Example. Current output Sensor ( Calex PC151HT Red:+24V, Black:Signal )
Figure 3 Current output sensor example
> Example. Resistance output Sensor ( PT100 ), Not support 3-wire RTD,
but if you want to use it, short the calibration line and use it.
Figure 4 Resistance output sensor
4.3 Digital input wiring
- Depends on type (NPN, PNP)
- You wind the sensor cable 2~3 times to the ferrite core for data reliability and electromagnetic
shielding.
> Example. NPN Proximity sensor (Brown : +24, Blue : GND, Black : Signal)
Figure 5 NPN-sensor, Need for wiring(1-5)
Inhaltsverzeichnis
Beliebte Tor Handbücher anderer Marken

LST
LST M500RFE-AS Bedienungsanleitung

Kinnex
Kinnex Media Gateway Bedienungsanleitung

2N Telekomunikace
2N Telekomunikace 2N StarGate Bedienungsanleitung

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Bedienungsanleitung

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Bedienungsanleitung

Telsey
Telsey CPVA 500 - SIP Bedienungsanleitung