Uniwide XtremeServer 2544 Bedienungsanleitung


Part I. User’s Guide
1. Introduction.............................................................................................2
1.1 System Feature................................................................................................................................3
1.1.1 Front View..........................................................................................................................3
1.1.2 Front Panel Controls and Indicators......................................................................................3
1.1.3 Rear View...........................................................................................................................4
1.1.4 Inner View..........................................................................................................................5
1.1.5 Power LED Indication ..........................................................................................................5
1.2 System Specifications.......................................................................................................................6
1.3 Mainboard Layout ............................................................................................................................9
1.3.1 Block Diagram.....................................................................................................................9
1.3.2 Mainboard Layout..............................................................................................................10
2. Important Safety ...................................................................................11
2.1 Intended Application Uses ..............................................................................................................11
2.2 Checking the Power Cord................................................................................................................11
2.3 Multiple Power Sources...................................................................................................................12
2.4 Earth-Grounded Socket Outlets.......................................................................................................12
2.5 Before Removing the Access Covers................................................................................................12
2.6 Fans..............................................................................................................................................12
2.7 Electrostatic Discharge (ESD)..........................................................................................................13
2.8 Cooling and Airflow........................................................................................................................13
2.9 Battery..........................................................................................................................................13
3. System Installation................................................................................14
3.1 Preparing for Setup........................................................................................................................14
3.1.1 Unpacking ........................................................................................................................14
3.1.2 Packing List.......................................................................................................................15
3.1.3 Environmental Specifications..............................................................................................16
3.1.4 Install Rail for Mounting the System on the Rack.................................................................17
3.1.5 Install System at the Rack Cabinet .....................................................................................19
3.2 Installing User Serviceable Component............................................................................................20
3.2.1 CPU..................................................................................................................................20
3.2.2 Memory............................................................................................................................21
3.2.3 Hard Disk Drives ...............................................................................................................24
3.2.4 PCI Add-on Cards..............................................................................................................25
3.2.5 Power Module Hot Plugging ...............................................................................................26
4. BIOS and Jumper Setting ......................................................................27
4.1 BIOS .............................................................................................................................................27
4.1.1 Starting BIOS Setup ..........................................................................................................27
4.1.2 Updating BIOS Setup........................................................................................................28
4.1.3 Using Setup ......................................................................................................................29
4.1.4 Main Menu........................................................................................................................30
4.1.5 Advanced Menu.................................................................................................................30
4.1.6 PCI PnP Menu...................................................................................................................40
4.1.7 Boot Menu........................................................................................................................42
4.1.8 Security Menu...................................................................................................................43
4.1.9 Chipset Configuration Menu...............................................................................................45

4.1.10 Power Menu....................................................................................................................49
4.1.11 Exit Menu........................................................................................................................50
4.2 Jumper Setting ..............................................................................................................................51
4.2.1 PCI-X Speed Setting(J22, J26)............................................................................................52
4.2.2 VGA Enable / Disable(J18).................................................................................................53
4.2.3 Clear CMOS Header...........................................................................................................53
4.2.4 CPU Board Detection Enable / Disable(J2)...........................................................................54
4.2.5 External SAS Port Enable/Disable(JP2)................................................................................54
4.2.6 Geographical ID Setting.....................................................................................................54
4.2.7 SAS Cable Connection........................................................................................................56
4.2.8 Jumper Setting on the SAS BP............................................................................................56
5. Software & Utilities .............................................................................57
5.1 LSILogic SAS RAID.........................................................................................................................57
5.1.1 Introduction to Integrated RAID.........................................................................................57
5.1.2 Integrated Mirroring Overview ...........................................................................................58
5.1.3 Creating Integrated Mirroring Volumes ...............................................................................64
5.1.4 Integrated Striping Overview .............................................................................................71
5.1.5 Creating Integrated Striping Volumes .................................................................................74
5.2 ServerDome Overview....................................................................................................................79
Part II. Technical Guide
1. Removing & Installing System Components..........................................80
1.1 Installing the CD-ROM Drive ...........................................................................................................80
1.2 Installing the Floppy Disk Drive.......................................................................................................81
1.3 Installing the Hard Disk Drive .........................................................................................................83
1.4 Removing the Power Supply Unit ....................................................................................................84
1.5 Replacing the Cooling Fan Unit........................................................................................................85
1.6 Replacing the Interface Unit ...........................................................................................................86
1.6.1 Backplane Unit..................................................................................................................86
1.6.2 SAS Cable.........................................................................................................................87
1.7 Installing the Motherboard..............................................................................................................88
1.8 Installing the CPU Board.................................................................................................................89
1.9 Installing the CPU Heatsink.............................................................................................................91
1.10 Installing the Front Bezel..............................................................................................................92
Appendix....................................................................................................93
A. BIOS Post Code .................................................................................................................................93

1
Preface
The information in this User's Guide has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no
commitment to update or to keep current the information in this Guide, or to notify any person or organization of
the updates.
NOTE: For any up-to-date version of this document, please see our web site at www.uniwide.com.
UNIWIDE Technologies, Inc. reserves the right to make changes to the product described in this manual at any
time and without notice. This product, including software, if any, and documentation may not, in whole or in part,
be copied, photocopied, reproduced, translated or reduced to any medium or machine without written consent.
Copyright Notice
The material in this document is the intellectual property of UNIWIDE Technologies, Inc.
We take every care in the preparation of this document, but no guarantee is given as to the correctness of its
contents. Our products are under continual improvement and we reserve the right to make changes without
notice.
Technical Support
If a problem arises with your system and no solution can be obtained from the user's manual, please contact your
place of purchase or local distributor. Alternatively, please try the following help resources for further guidance.
Visit the UNIWIDE website for FAQ, technical guide, BIOS updates, driver updates, and other information:
http://www.uniwide.com/
Revision History
Revision RevisionHistory Date
V1.0 First release December 2006

2
1. Introduction
The key objective for XtremeServer is to overcome the major challenges faced by developers, and system
integrators alike, in deploying ideal server solutions to the market. Although many, key challenges are identified
as reliability, performance, value, scalability and manageability. XtremeServer offers the best in class for each of
these challenges by employing the latest technology designed by a specialized sever team.
The XtremeServer 2544 2U Rackmount Server is a high-performance system powered by dual AMD®OpteronTM
Processors, nVIDIA®nForce Professional 2200 & 2050, AMD 8132 PCI-X Tunnel chipset, ADM1026 Hardware
Monitoring Chip.
In addition, 8 DIMM sockets are supported per CPU. This first-in-industry feature increases the performance/value
mix by reducing the cost of system memory by up to 100% over competition.
In line with extreme processing and data buffering capability, XtremeServer is equipped with both PCI-Express
and PCI-X slots and SAS with RAID 0, 1 support. For those preferring SAS devices, 4-slot SAS with RAID is
available. Data transfer is optimized with on-board dual PCI-Express Gigabit Ethernet ports.
Server management feature is unrivaled by utilizing its dedicated BMC with IPMI 2.0 based ServerDome.
A remote management suite handles all aspects of deployment, management and monitoring of XtremeServer at
an individual or aggregate level. Last but not least, XtremeServer is cable-less and tool-less integration.
This well thoughtout packaging keeps all variations of XtremeServer ultra cool and easy to maintain, thus,
optimizing on reliability and TCO.

3
d. Hard Disk Drive
e. Front Bezel
f. Mounting Bracket
a. Slim CD-ROM Drive
b. Front Panel Controls and
Indicators
c. FDD Ejector button
1.1 System Feature
1.1.1 Front View
1.1.2 Front Panel Controls and Indicators
Front Side LEDs
LED Color State Description
Blue On System is turned on
System Power Off Off Power is off
Green Blink Network is linked and accessed
LAN1/LAN2 Activity Green Off No LAN access
White On Identification is active by management software
or ID LED button
System ID Off Off Identification is not active
Off Off Running/normal operation
System Fault Red On Critical or non-recoverable condition
Green On HDD exists and is powered
HDD Status Off Off No HDD
Green Blink Disk is accessed
Red Blink Disk has problem or on Rebuilding
HDD Activity/Fail
Off Off No disk activity
a. USB 2,0 Ports
b. Power LED
c. LAN Activity LED
d. System ID LED
e. System Fault LED
f. System ID Switch
g. Reset Switch
h. Power ON/OFF Switch

4
1.1.3 Rear View
LAN Port Function
The LAN port uses a CAT 6 LAN cable for connecting the motherboard to a local area network
by means of a network hub. The port has 2 indicator LEDs.
LED Color State Description
Green Blink LAN is linked and accessed
Link and Activity Off Off LAN is not linked
Orange On 1000M mode connected
Green On 100M mode connected
Speed
Off Off 10M mode connected
Link and Activity LED Speed LED
h. KVM over IP
i. IEEE 1394 Port
j. GbE LAN Port(IPMI)
k. GbE LAN Port
l. External SAS Port
m. AC Power Inlet
a. PCI Slots
b. System Geographical ID Switch
c. VGA Port
d. Serial Port
e. PS/2 Port(Keyboard & Mouse)
f. USB 2.0 Ports

5
1.1.4 Inner View
1.1.5 Power LED Indication
AC : Green –Normal / Yellow - Fail
DC : Green –Normal / Yellow –Fail
FAN : Green –Normal / Yellow - Fail
NOTICE
You can check the power status LED after the front bezel is removed.
a. Power Supply
b. Silm FDD
c. Silm CD-ROM
d. Center Fan
e. AC protection cover
f. Memory DIMM Slots
g. CPU/Memory Air Duct
h. PCI-Express Add-on Card(Option)
i. PCI-Express Add-on Cards
j. PCI-X Add-on Cards
k. AC inlet

6
1.2 System Specifications
Processor
Four socket F (1207pin) AMD OpteronTM Processors
Supports up to 4P/8C Dual-Core AMD OpteronTM 8000 Series processors
Integrated 128bit DDR-2 memory controller
Chipset
NVIDIA® nForceTM Professional 2200
AMD-8132TM PCI-X 2.0 Tunnel
NVIDIA® nForceTM Professional 2050
Winbond Super I/O chip
Analog Devices®hardware monitoring chip
Memory
128-bit dual channel memory bus
Eight DIMMs per CPU, up to 128GB memory capacity
Registered ECC DDR2 400/533/667 SDRAM DIMM
SAS Controller
LSILogic LSI1068X 8-ch SAS controller
4-CH shared with External SAS port
LSILogic Integrated RAID & ZCR support
IDE Controller
Integrated nForceTM Professional 2200
One port for CD-ROM Drive
2.5" HDD (Optional)
Drive Bays
Supports four hot-swap SATA HDD or
Supports four hot-swap 3.0 SAS HDD
Supports Slim CD-ROM and Slim FDD Drive

7
Expansion Slots (Only Support Low Profile Card)
Two x16 PCI-Express slot supporting full-length add-on card
One x4 PCI-Express slot supporting half-length add-on card
Two 64bit 133/100/66MHz PCI-X slot supporting half-length add-on card
One 64bit 133/100/66MHz PCI-X slot supporting full-length add-on card for ZCR
Integrated I/O
Rear I/O
One VGA port
One serial port
One PS/2 keyboard & mouse port
Two USB 2.0 ports
Two RJ45 GbE ports
One IEEE-1394a (Firewire) port
One external SAS connector
Front LED Panel
Two USB 2.0 ports
LEDs: Power / GbE LAN1 / GbE LAN2 / ID / System Fault
Switches: System ID / Reset / Power
System Management
FAN connectors
For CPU / System - Two step speed control
Port 80h 7 segment display
BMC
Supports IPMI 2.0 specification
Auto fan speed control
Voltage and fan speed monitoring
LAN Controller
Two Broadcom®BCM5721 PCI-Express gigabit Ethernet controllers
Support PXE function
Video Controller
XGI Volari Z9 /16MB
Inhaltsverzeichnis
Andere Uniwide Server Handbücher
Beliebte Server Handbücher anderer Marken

iRobo
iRobo IPC2U Bedienungsanleitung

Nortel
Nortel 1000 Con?guration guide Bedienungsanleitung

Asus
Asus AP7500 Bedienungs- und Wartungshandbuch

Avid Technology
Avid Technology AirSpeed 5000 Bedienungsanleitung

HP
HP Integrity rx2600 Installationsanleitung

Milestone
Milestone Husky IVO 350T Bedienungsanleitung