Unova Intermec SmartPass AI1620 Bedienungsanleitung

P/N 411425
Field Installation Guide
AI1620 SmartPass
®

Information in this document is subject to change and does not represent a commitment on the part of
Amtech Systems Corporation.
© 1998-1999 Amtech Systems Corporation. (Amtech Systems Corporation is a wholly owned subsidiary
of Intermec Technologies Corporation.) All rights reserved. No portion of this publication may be
reproduced or transmitted in any form by any means without prior written permission of Amtech
Corporation.
Aspects of the wireless data and security equipment and systems marketed by Amtech Systems
Corporation and its affiliates are protected by patents and patents pending in the United States and other
countries.
Amtech, Dynamic Tag, Dynicom, Intellitag, PassKey, RideMaster, SmartPass, and TollTag are either
trademarks or registered trademarks of Amtech Systems Corporation.
All other trademarks listed are the property of their respective owners. Throughout this manual,
trademarked names may be used. Rather than put a trademark (™ or ®) symbol in every occurrence of a
trademarked name, we state that we are using the names only in an editorial fashion and to the benefit of
the trademark owner, with no intention of infringement. Printed in the U.S.A.
For further information, contact:
Amtech Systems Corporation
19111 Dallas Parkway, Suite 300
Dallas, Texas 75287-3106 USA
Phone: (972) 733-6600
Fax: (972) 733-6699
Amtech Response Center
19111 Dallas Parkway, Suite 300
Dallas, Texas 75287-3106 USA
Phone: (972) 733-6681
Fax: (972) 733-6695

WARNING TO USERS IN THE UNITED STATES
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY
INTERFERENCE STATEMENT
47 CFR §15.105(a)
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in a
commercialenvironment. This equipment generates, uses, and can radiate radio frequency (RF) energy and
may cause harmful interference to radio communications if not installed and used in accordance with the
instruction manual. Operating this equipment in a residential area is likely to cause harmful interference, in
which case, depending on the laws in effect, the users may be required to correct the interference at their
own expense.
NO UNAUTHORIZED MODIFICATIONS
47 CFR §15.21
CAUTION: This equipment may not be modified, altered, or changed in any way without permission from
Amtech Corporation. Unauthorized modification may void the equipment authorization from the FCC and
will void the Amtech warranty.
USE OF SHIELDED CABLES IS REQUIRED
47 CFR §15.27(a)
Shielded cables must be used with this equipment to comply with FCC regulations.
A license issued by the FCC is required to operate this RF identification device in the United States.
Contact Amtech Corporation for additional information concerning licensing requirements for specific
devices.
Amtech Corporation
USA



Contents
vii
Table of Contents
Installing SmartPass
Getting Started 1-3
Contents of Shipping Carton 1-3
Installation Accessory Kits 1-3
Materials Required 1-3
Electrical and Communications Requirements 1-4
Junction Box 1-4
Power and Communications Cable 1-5
Electrical Power 1-5
Installing SmartPass on a Round Pole 1-6
Mounting SmartPass to a Wall or Ceiling 1-9
Connecting and Testing Power 1-14
Connecting the AC Power Supply 1-14
Connecting the DC Power Supply 1-14
Testing Power Connections 1-15
Connecting Communications 1-15
Connecting SmartPass to the PC 1-15
Using an RS-232 Interface 1-16
Using an RS-422 Interface 1-17
Using a Wiegand Interface 1-18
Controlling RF Transmission 1-20
Vehicle Detector Control 1-21
Host Control 1-21
Continuous RF Transmission 1-21
Connecting Sense Input and Sense Output Circuits 1-21
Connecting Sense Input Circuits 1-21
Connecting Sense Output Circuits 1-22
Testing Procedures 1-24
Verifying PC-to-SmartPass Communications 1-25
Verifying Tag to SmartPass Communications 1-28
1

AI1620 SmartPass Field Installation Guide
viii
Configuring SmartPass Parameters 1-29
Factory Default Settings 1-30
Marking the Read Zone 1-31
Materials Required 1-32
Marking Procedures 1-32
Fine-Tuning and Verifying the Read Zone 1-33
Software Commands 1-35
Command Listings 1-36
Troubleshooting
Symptoms and Remedies 2-3
Technical Support 2-5
Find Something Wrong or Want to Suggest an
Improvement? 2-5
2

Contents
ix
List of Figures
Figure 1-1 Factory-Mounted Bracket 1-7
Figure 1-2 Pole Mount Bracket Assembly 1-7
Figure 1-3 SmartPass Mounted Using Pole Mount Bracket 1-8
Figure 1-4 Front and Top Views of SmartPass Position 1-9
Figure 1-5 Wall Mount Bracket Accessory 1-10
Figure 1-6 Wall Mount Bracket Attached to SmartPass 1-11
Figure 1-7 Factory Mount Bracket Attached to Wall Mount Bracket 1-12
Figure 1-8 Pole Mount Bracket Attached to Wall 1-12
Figure 1-9 Connecting SmartPass Assembly to Pole Mount Bracket 1-13
Figure 1-10 DB9 and DB25 Connector Pin Assignments for Signal to
Host 1-16
Figure 1-11 SmartPass RF Control Options 1-20
Figure 1-12 Sample Circuit Connections 1-22
Figure 1-13 Status Window 1-25
Figure 1-14 Find Reader Options 1-26
Figure 1-15 Communications Established Message 1-26
Figure 1-16 Reader Not Found Message 1-27
Figure 1-17 Successful Tag Read 1-28
Figure 1-18 Second Successful Tag Read 1-29
Figure 1-19 Sample Read Zone Marking Pattern 1-33
Figure 1-20 Range Value Dialog Box 1-34

AI1620 SmartPass Field Installation Guide
x
List of Tables
Table 1-1 Installation Accessory Kits 1-3
Table 1-2 Connector Cabling Accessory Kits 1-5
Table 1-3 Power Supply Current Requirements 1-5
Table 1-4 Cable length from Amtech-Supplied 110 V AC to 18 V AC
Transformer to AI1620 SmartPass 1-6
Table 1-5 AC Transformer Connections for Colored Pair Wire Cable 1-14
Table 1-6 Low Voltage DC Cable Connections for the Colored Pair
Wire Cable 1-14
Table 1-7 RS–232 Interface Signal Wiring for Colored Wire Pair
Cable 1-17
Table 1-8 RS–422 Interface Signal Wiring for Colored Wire Pair
Cable 1-18
Table 1-9 Wiegand Interface Signal Wiring for Colored Wire Pair
Cable 1-19
Table 1-10Sense Input/Output Cabling Assignments for Colored
Wire Pair Cable 1-23
Table 1-11SmartPass Default Configuration Settings 1-30
Table 1-12SmartPass Commands Listed by Command Name 1-36
Table 2-1 Symptoms and Remedies 2-3
Inhaltsverzeichnis
Beliebte Kartenleser Handbücher anderer Marken

Rosslare
Rosslare DR-6255 Bedienungsanleitung

Lindy
Lindy 51541 Bedienungsanleitung

Diapro T?bbi Ürünler
Diapro T?bbi Ürünler Across System Bedienungsanleitung

Johnson Controls
Johnson Controls Kantech tyco ioSmart Bedienungsanleitung

ACS
ACS ACR122L Bedienungsanleitung

Secukey
Secukey S2-MF Bedienungsanleitung