UseTECH FlowTimer+ Bedienungsanleitung

FlowTimer+ Connect
FlowTimer+ Interface for Smart Home
and other external systems
Operating Manual

Publisher
usetech GmbH
Tanzplatz 10
D- 55130 Mainz
Phone:
+49 6131 - 921325
Website:
www.use-tech.com
Document
number
FlowTimer+ Connect_Manual_EN_V3
Original Operating Manual
Date of issuance
04.03.2019
Printing date
04.03.2019
Copyright
usetech GmbH
This documentation including all its parts is protected by copyright.
Any use or modification outside the narrow limits of copyright law
without the consent of the company usetech GmbH is prohibited
and punishable by law.
This applies in particular to duplications, translations, microfilming
and storage in electronic systems as well as processing in these.

Table of contents
03/19 FlowTimer+ Connect 1
Table of contents
Table of contents.........................................................................1
1General information.............................................................2
1.1 Explanation of symbols .........................................................2
2Technical data......................................................................4
2.1 Electrical data........................................................................4
2.2 Environmental and climate conditions...................................4
2.3 Lifetime..................................................................................4
3Intended Use ........................................................................5
3.1 Non-approved use.................................................................6
4Basic safety instructions.....................................................7
5System description FlowTimer+ Connect ..........................8
5.1 Content of the FlowTimer+ Connect .....................................8
6Installation............................................................................9
6.1 Electrical connection .............................................................9
7Operation and Function.....................................................10
7.1 Operating conditions ...........................................................10
7.1.1 Normal operation...........................................................................10
7.1.2 Restarting the system....................................................................10
8Troubleshooting, Maintenance .........................................11
8.1 Maintenance........................................................................12
9Packaging, Transport, Storage .........................................13
10 Disposal..............................................................................14
11 EC Declaration of Conformity ...........................................15

General information
03/19 FlowTimer+ Connect 2
1 General information
The operating instructions describe the entire life cycle of the
system. Keep this manual in such a way that it is easily accessible
to any user and available to any new owner of the system.
NOTE
The operating instructions contain important
information on safety!
Non-observance of these instructions can lead to dangerous
situations.
The operating instructions must be read and understood.
1.1 Explanation of symbols
DANGER
Warns of imminent danger!
Failure to do so will result in death or serious injury.
WARNING
Warns of a potentially dangerous situation!
Failure to do so could result in serious injury or death.
CAUTION
Warns of a possible hazard!
Failure to do so may result in moderate or minor injury.
NOTE
Warns of material damage!
Failure to do so may result in damage to the system or
equipment.

General information
03/19 FlowTimer+ Connect 3
indicates important additional information, tips and
recommendations that are important for your safety and the
proper functioning of the system.
refers to information in this operating manual or other
documentation.
Action steps
The defined sequence of steps makes it easier for you to
use the system correctly and safely.
Outcome
Here you will find the result of a sequence of steps
described.

Technical data
03/19 FlowTimer+ Connect 4
2 Technical data
2.1 Electrical data
Input voltage: 100 - 240V~
Power consumption: < 0.25 W
Supply connection: Micro USB socket
2.2 Environmental and climate conditions
Ambient temperature: +5°C - 40°C
Protection class: IP20
Location: only suitable for indoor use
2.3 Lifetime
The function of FlowTimer+ Connect must be checked by a
qualified technician at the scheduled intervals (see also chapter
9.3).

Intended Use
03/19 FlowTimer+ Connect 5
3 Intended Use
Please observe the notes in this operating manual as well as the
operating conditions and permissible data in the data sheet so that
the system functions perfectly and remains operational for a long
time. In case of non-observance of these instructions as well as in
case of inadmissible interventions into the system, any liability on
our part is void, as is the warranty on the system and accessories!
FlowTimer+ Connect connects the FlowTimer+ I/O connector to an
external switched mains voltage.
If the supplied USB power supply is supplied with mains voltage,
the FlowTimer+ will lock up immediately.
An alarm reset can only be performed via the connected
FlowTimer+ or its supply voltage.
The precondition for this is also that the mains voltage for the
FlowTimer+ Connect has been switched off at least 1 minute
before.
Any other use or use going beyond this shall be deemed improper
use. The usetech GmbH is not liable for damages resulting from
this. The risk is borne solely by the user.

Intended Use
03/19 FlowTimer+ Connect 6
3.1 Non-approved use
Unapproved use in the sense of a foreseeable misuse shall be
deemed to be improper use:
The I/O connection cable of the FlowTimer+ Connect is only
suitable for connection to the FlowTimer+.
The FlowTimer+ Protect is not directly supported, but only
indirectly via a group alarm via FlowTimer+ and FlowTimer+
Hub.
No telephones, ISDN, other devices or adapters may be
connected.
The USB plug of the I/O connection cable may only be operated
with the supplied USB power supply. Other 5V voltage sources
(PC etc.) must be galvanically isolated for safety reasons!

Basic safety instructions
03/19 FlowTimer+ Connect 7
4 Basic safety instructions
WARNING
Electrical voltage can be life-threatening.
The installation of a stationary power supply must be
carried out by a qualified electrician.
The system must be commissioned and, if necessary,
adapted by a specialist. The local conditions must be
observed.

System description FlowTimer+ Connect
03/19 FlowTimer+ Connect 8
5 System description FlowTimer+ Connect
5.1 Content of the FlowTimer+ Connect
Fig. 5.1: Content of the FlowTimer+ Connect
1
USB power supply unit
2
Interface electronics in USB connector
3
USB-I/O connection cable
4
I/O connector plug
Andere Handbücher für FlowTimer+
3
Inhaltsverzeichnis
Beliebte Aufnahmegeräte Handbücher anderer Marken

Strymon
Strymon NIGHTSKY Bedienungsanleitung

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Bedienungsanleitung

Tews Technologies
Tews Technologies TPMC465 Bedienungsanleitung

Honeywell
Honeywell Excel 50 Bedienungsanleitung

SeaLevel
SeaLevel COMM+8.LPCI Bedienungsanleitung

Arturia
Arturia AUDIOFUSE STUDIO Bedienungsanleitung