2947560
AUX
IN
INPUTS
AUDIO CC PAGE
1234
+24V DC
K1 K2
NO
COM
NC
NC
COM
NO
AUX
OUTPUTS
ON
Network Connection
The VIP-801A-SA has one RJ-45 network
connector on the front panel. Use a standard
Ethernet patch cable to connect the
VIP-801A-SA to an Ethernet switch.
Signal Connections
The VIP-801A-SA has signal connectors on the
rear panel:
2 Audio outputs
2 Form C relays
1 Contact Closure Input (GPI)
Audio Out: Two audio output connections are
provided. The terminals labeled “Page” provide
a signal output compatible with Valcom
self-amplified speakers. Up to 40 Valcom
speakers can be connected to the Page output.
The terminals labeled “AUX” provide a signal
output compatible with most amplifiers and
should be used where a transformer-coupled
output is desired.
DIP Switch: The four-pole DIP switch controls
a supervision signal on the “Page” audio output
line. For systems where supervision is used,
setting DIP switches 1 & 2 to ON enables
supervision on the Page audio output
connections. Where supervision is not used, set
DIP switches 1 & 2 to OFF. Switches 3 & 4 are
not used.
Audio Input:
Not used with Syn-Apps.
Contact Closure:
The Contact Closure (CC) can be used as a
Syn-Apps General Purpose Input (GPI).
Relay Channels: Access to the form C relay is
provided via screw terminals (on a six pin screw
terminal block) labeled K1 and K2. The
common contact is the middle terminal with the
normally closed (N.C) contact on the left and the
normally open (N.O.) contact on the right. Relay
contacts are rated for 1A @ 24VDC.
Status Indicator Lights
The VIP-801A-SA has 3 status indication lights
on the front panel:
STATUS: Flashes during normal operation and
solid during system startup.
Green LED: (Link) Indicates Ethernet
connection when illuminated.
Yellow LED: (Activity) Indicator flashes to
indicate network activity.
Setup
The VIP-801A-SA will automatically acquire an
IP address (using DHCP) and connect to the
Syn-Apps server when connected to the network
and powered up. Information specific to your
application will need to be programmed into the
Syn-Apps server. Refer to the Syn-Apps
documentation for further information.
TECHNICAL ASSISTANCE
Assistance in troubleshooting is available from
the factory. Call (540) 563-2000 and press 1 for
Technical Support or via email at
support@valcom.com.
When requesting assistance, you should include
all available information. It is strongly suggested
that you go to the web site and review the
information at http://www.valcom.com/Syn-Apps.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating your
company name, address, phone number,
contact person and the nature of the problem.
Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
WARRANTY
Warranty information may be found on our
website at www.valcom.com/warranty.
Rear View