This conversion kit shall be installed by
a qualified service agency in accordance
with the manufacturer’s instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fire, explosion
or production of carbon monoxide
may result causing property damage,
personal injury or loss of life. The
qualified service agency is responsible
for the proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specified in the
manufacturer’s instructions supplied with
the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
700MNGK / 700MPGK Gas Conversion Kit
Use with Valor G3.5 700M Heater Models ONLY
INSTALLATION MANUAL
G3.5 Series
4008354-03
©2021, Miles Industries Ltd.
Kit Contents
• 1 Pilot injector
• 1 Main burner injector elbow
• 1 Air shutter
• 1 Pilot shield
• 1 Minimum rate bypass screw
• 1 Set of conversion labels
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) flat blade screwdriver, to set
pressure
• Small flat blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove bypass screw
• Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
• Manometer, to set pressure
Specifications
*bThis appliance is certified for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Model 700MN 700MP
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 26,000 26,000
Input Minimum (Btu/h) 13,000 11,000
Manifold Pressure (in w.c.) 3.5” 10”
Minimum Supply Pressure (in w.c.) 5” 11”
Maximum Supply Pressure (in w.c.) 10” 14”
Main Burner Injector Marking 750 260
Pilot Injector Marking 51 30
Min. Rate By-Pass Screw 175 105