Valor 541 Masquerade Gebrauchsanweisung

© GDC Group Ltd. 2014
5133673/06
NSTALLER: Please leave this guide with the owner
Model 541
ROOM SEALED RAD ANT / CONVECTOR
GAS F RE
Fitted with one of the following fascia’s.
Dream, Masquerade or
Excelsior
(GC No. 32-032-65)
We trust that this guide gives
sufficient details to enable this
appliance to be installed,
operated and maintained
satisfactorily. However, if
further information is required,
our Valor Technical Helpline
will be pleased to help.
Telephone 0844 879 35 88
(National call rates apply in the
United Kingdom).
n the Republic of reland
Telephone 01 842 8222.
I STALLER A D OW ER GUIDE
DON’T FORGET
To register your guarantee!
Call 0800 597 8500

© GDC Group Ltd.
All rights reserved. No part of this publication may be reproduced in any material form
(including photocopying), stored in any medium by electronic means (including in any
retrieval system or database) or transmitted, in any form or by any means, whether
electronic, mechanical, recording or otherwise, without the prior written permission of
the copyright owner.
Applications for the copyright owner's permission to reproduce any part of this
publication should be made, giving details of the proposed use, to the following
address: The Marketing Communications Manager, GDC Group Ltd, Millbrook House,
Grange Dive, Hedge End, Southampton, SO30 2DF.
Warning: Any person who does any unauthorised act in relation to a copyright work
may be liable to criminal prosecution and civil claims for damages.
Valor, GDC Group Ltd, Millbrook House, Grange Dive,
Hedge End, Southampton, SO30 2DF.
www.valor.co.uk
Because our policy is one of constant development and improvement, details may vary
slightly from those given in this publication
Page 2
© GDC Group Ltd. 2014
THIS APPLIA CE IS FOR USE WITH ATURAL GAS (G20).
U DER O CIRCUMSTA CES IS THIS FIRE TO BE CO VERTED TO LPG.
A LPG KIT DOES OT EXIST FOR THIS GAS FIRE.
THIS APPLIA CE IS SUITABLE O LY FOR I STALLATIO I THE U ITED
KI GDOM (GB) A D THE REPUBLIC OF IRELA D (IE).

Page 3
Safety First.
Valor Fires fires are CE Approved and designed to meet the appropriate British
Standards and Safety Marks.
Quality and Excellence.
All Valor Fires fires are manufactured to the highest standards of quality and
excellence and are manufactured under a BS EN SO 9001 quality system accepted
by the British Standards nstitute.
The Highest Standards
Valor Fires is a member of SBG and HH C (Heating and Hot water ndustry Council)
that work to ensure high standards of safety, quality and performance.
Careful Installation
This gas fire must be installed by a competent GAS SAFE REG STER engineer
(GAS SAFE REG STER or CORG engineer outside of UK) in accordance with our
installer guide and should not be fitted directly on to a carpet.
© GDC Group Ltd. 2014

Page 4
© GDC Group Ltd. 2014
NSTALLER GU DE
FOR OWNER GU DE SEE PAGES 47 TO 59
NSTALLER GU DE

CO TE TS
Section Heading Page
I STALLER GUIDE 4 - 46
OW ER GUIDE 47 - 59
1. SAFETY 7
2. APPLIA CE DATA, EFFICIE CY A D Ox 8
2.1 General information. 8
2.2 Efficiency. 9
3. LIST OF AVAILABLE KITS 9
4. APPLIA CE A D RECESS DIME SIO S 10
5. GE ERAL I STALLATIO REQUIREME TS 12
5.1 Regulations, Standards and Law. 12
5.1.1 Considerations for timber framed buildings. 12
5.2 Ventilation requirements. 12
5.3 Fireguard requirements. 13
5.4 Room considerations. 13
5.5 Fireplace preparation. 13
5.6 The surround. 13
5.7 Hearth / plinth requirements. 14
5.8 Fireplace clearances. 15
5.9 nstallation options. 16
5.10 Terminal guard and terminal clearances. 16
6. U PACKI G A D PRELIMI ARY CHECKS 18
6.1 Unpacking. 18
6.2 Appliance disassembly. 19
6.3 Preliminary checks. 20
7. GAS SUPPLY CO ECTIO 21
8. WALL PREPARATIO 22
8.1 Select appliance position. 22
8.2 Constructing a recessed opening. 22
8.2.1 Fitting a lintel. 22
8.2.2 Preparing a wall cavity. 23
8.3 Combustible wall materials. 23
8.4 Cutting the flue hole for brick, stone etc. building. 24
8.5 Cutting the flue hole in timber frame buildings. 24
8.6 Prepare appliance fixing holes. 26
Page 5
© GDC Group Ltd. 2014
NSTALLER GU DE
Continued on next page

Section Heading Page
9. FLUE TERMI AL I STALLATIO 26
9.1 Cutting flue to size. 26
9.2 Fitting to wall. 28
9.3 Fitting the terminal guard. 29
10. GAS CO ECTIO 29
11. CERAMIC COALS I STALLATIO 30
12. CERAMIC PEBBLES I STALLATIO 32
13. WI DOW FITTI G 34
14. FULL OPERATI G CHECKS 34
14.1 Check for leaks. 34
14.2 Check control operation. 34
14.3 Checking inlet pressure. 35
15. FASCIA FITTI G 36
15.1 Fitting the Masquerade fascia 36
15.2 Fitting the Excelsior fascia. 37
15.3 Fitting the Dream fascia. 38
16. FI AL REVIEW 39
17. SERVICI G & PARTS REPLACEME T 40
17.1 To remove the fascia. 40
17.2 To remove or clean the window unit. 42
17.3 To remove the ceramic fuel effect and rear wall. 43
17.4 To replace the ceramic fuel effect. 43
17.5 To remove the complete burner module. 43
17.6 To remove the burner from the burner module. 44
17.7 To remove the injector. 44
17.8 To remove the pilot unit. 44
17.9 To remove the gas valve. 45
17.10 To remove the switch and wiring loom. 45
Page 6
© GDC Group Ltd. 2014
NSTALLER GU DE
CO TE TS (Continued)

1. SAFETY
Installer
Before continuing any further with the installation of this appliance please read the
following guide to manual handling:
-The approximate lifting weight (kg) of this appliances are as below:
Model Heat Engine Fascia / Fire front Combined Weight
Dream 12.3 13.1 25.4
Masquerade 12.3 12.1 24.4
Excelsior 12.3 12.6 24.9
-One person should be sufficient to liftthe fire. f for any reason this weight is
considered too heavy then obtain assistance.
-When lifting always keep your back straight. Bend your legs and not your back.
-Avoid twisting at the waist. t is better to reposition your feet.
-Avoid upper body/top heavy bending. Do not lean forward or sideways whilst
handling the fire.
-Always grip with the palm of the hand. Do not use the tips of fingers for support.
-Always keep the fire as close to the body as possible. This will minimise the
cantilever action.
-Use gloves to provide additional grip.
-Always use assistance if required.
This product uses a fuel effect, a burner compartment rear wall and gaskets
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to these materials may cause irritation to
eyes, skin and respiratory tract. Consequently, it is important to take care when
handling these articles to ensure that the release of dust is kept to a minimum.
To ensure that the release of fibres from these RCF articles is kept to a
minimum, during installation and servicing we recommend that you use a HEPA
filtered vacuum to remove any dust and soot accumulated in and around the
fire before and after working on the fire. When replacing these articles we
recommend that the replaced items are not broken up, but are sealed within a
heavy duty polythene bag, clearly labelled as RCF waste. RCF waste is classed
as a stable, non-reactive hazardous waste and may be disposed at a landfill
licensed to accept such waste. Protective clothing is not required when
handling these articles, but we recommend you follow the normal hygiene rules
of not smoking, eating or drinking in the work area and always wash your
hands before eating or drinking. This appliance does not contain any
component manufactured from asbestos or asbestos related products.
Page 7
© GDC Group Ltd. 2014
NSTALLER GU DE

2. APPLIA CE DATA A D EFFICIE CY.
2.1 General information.
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does not exist for this gas fire.
The appliance information label is located on a plate at the base of the fire. This can
be seen by removing the lower front casting / fire front.
Before continuing with the installation of this appliance please complete the
information on the last pages of the owner guide.
Page 8
© GDC Group Ltd. 2014
NSTALLER GU DE
Gas Natural
nlet pressure 20mbar
nput - Max. (Gross) 3.65kW (12,454 Btu/h)
nput - Min. (Gross) 1.5kW (5,118 Btu/h)
nlet pressure (Cold) 20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
Gas connection 8mm pipe
Main burner Simplex aerated
Burner injector Cat. 92 size 280
Pilot unit Left side of firebox. Combined pilot jet, thermocouple sensor
and electrode. S T ref. NGOP9706
gnition ntegral piezo on gas valve.
Aeration adjustment None required
Controls
Manual pilot and main burner off/on control (Right control).
Separate variable control (Left control) for main burner can be
operated by its control knob or from the high level rocker
switch. Fitted with flame supervision device and integral piezo
igniter
Batteries 4 x 1.5V AA
Walls Minimum 102mm (4in.) thick.
Maximum 660mm (26in.) thick.

2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS EN 613 and
the result is as below:
Model Efficiency % (Gross)
541 76
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
3. LIST OF AVAILABLE KITS
Description Part number
-Spacer kit (5 inch) 0595121
-Spacer kit (3 inch) 0595131
Page 9
© GDC Group Ltd. 2014
Gas Conversion factor from net to gross efficiency
Natural Gas 0.901
NSTALLER GU DE

4. APPLIA CE A D RECESS DIME SIO S
This appliance must not be recessed into a combustible wall.
Page 10
© GDC Group Ltd. 2014
NSTALLER GU DE
Figure 1. Appliance dimensions and clearances (Fire dimensions are subject to
manufacturing deviation). Fascia may differ from that shown.
Key Description
Model
Masquerade Excelsior Dream
A Appliance height (mm) 635 635 635
B Appliance width (mm) 518 518 518
C Appliance depth into room (mm) 135 135 135
D
Minimum mandatory clearance to
combustible surfaces projecting
beyond the front of appliance (mm).
102 102 102
E
Recommended clearance to non-
combustible surfaces for access
purposes (mm).
51 51 51
See Figure 4.
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere Valor Heizung Handbücher
Beliebte Heizung Handbücher anderer Marken

Empire Heating Systems
Empire Heating Systems WCC65 Bedienungsanleitung

Wetekom
Wetekom 92 86 43 Bedienungsanleitung

Desa
Desa SPC170-F Bedienungsanleitung

Watlow
Watlow Watrod Electric Tubular Heaters Bedienungsanleitung

Haverland
Haverland ECO-DRY GPS Series Stücklistenhandbuch

Stelpro
Stelpro ASILVC2060 Series Bedienungsanleitung