6
Specifications
Approval & Codes
This appliance is certified to ANSI Z21.88/CSA 2.33
American National Standard / CSA Standard for Vented
Gas Fireplace Heaters for use in Canada and USA, and
to CGA 2.17-91 High Altitude Standard in Canada. This
appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fireplace efficiencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas
and Propane Installation Code CAN/CGA-B149.1. Only
qualified licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Ratings
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certified without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confirm.
For installations at elevations above 4,500 feet (1,370 m)
in Canada, please consult provincial and/or local
authorities having jurisdiction.
Model 2200KN 2200KP
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 36,000 36,000
Input Minimum (Btu/h) 19,000 21,000
Manifold Pressure (in w.c.) 3.7” 9.0”
Minimum Supply Pressure (in w.c.) 5” 11”
Maximum Supply Pressure (in w.c.) 10” 14”
Main Burner Injector Marking DMS#32 DMS#49
Pilot Injector Marking 51 30
Min. Rate By-Pass Screw 220 160
Supply Gas
Heater engines 2200KN is used with natural gas.
Heater engines 2200KP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section.
The supply connection
is 1/2” NPT male and
located on the on the
rear left side of the
firebox.
A shut-offvalve (supplied) is required on the supply line
to isolate the unit during service. See Set-up Gas Supply
section for details.
Conversion Kits
The 2200K is supplied as natural gas or propane gas
and is field convertible between fuels. See instructions
packaged with the conversion kits for further
information.
Electrical
The 2200K is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power to
operate the interior lighting, the optional WiFi module
or the optional 1270RBK Remote Blower Kit.
This appliance is designed and approved as a
supplemental heater and provides the potential for
most energy conservation when used while attended.
The use of an alternate primary heat source is
advisable.
X
WARNING
Please note that the HeatShift Kit MUST be
installed on this appliance!