Approval & Codes
This appliance is certified to ANSI Z21.88/CSA 2.33
American National Standard / CSA Standard for
Vented Gas Fireplace Heaters for use in Canada and
USA, and to CGA 2.17-M91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fireplace efficiencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas
and Propane Installation Code CAN/CGA-B149.1. Only
qualified licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Ratings
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certified without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confirm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Model 650JN 650JP
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 24,000 24,000
Input Minimum (Btu/h) 6,500 13,000
Manifold Pressure (in w.c.) 3.95” 10”
Minimum Supply Pressure (in w.c.) 5” 11”
Maximum Supply Pressure (in w.c.) 10” 14”
Main Burner Injector Marking 82-650 92-260
Pilot Injector Marking 35 27
Min. Rate By-Pass Screw 125 125
Supply Gas
Heater engine 650JN is
used with natural gas.
Heater engine 650JP is
used with propane gas.
The supply pressure must
be between the limits
shown in the Ratings
section.
The supply connection is 3/8” NPT. The opening of the
gas supply line is at the left side of the appliance.
Venting Options
Co-axial direct vent installations (solid piping)
A list of all approved venting accessories can be
found in section Approved Venting Components pages
42–43 in this manual.
Note: An 817VAK Vent Adapter is required in all cases.
Co-linear direct vent installations (flexible
piping)
Converts the appliance outlet collars to accept two
3-inch diameter flex liners for installation into existing
solid-fuel burning fireplaces and chimneys. requires
a co-linear adapter at the appliance and either a co-
linear terminal or co=linear-to-co-axial adapter and
terminal at the top of teh chimney. A list of approved
venting accessories can be found in section Approved
Venting Components pages 42–43 in this manual.
Gas Conversion
The 650J fireplace is offered with natural gas or
propane gas. It can be converted from one gas to the
other. See installation manual supplied with the gas
conversion kit for more information.
Outdoor Conversion Kit
The 650J model is supplied standard for indoor
applications and may be adapted for installation in
specific “outcoor” applications protected from weather
as defined in the GV60CKO Outdoor Conversion Kit
manual.
Specifications