MULTIROOM TEMPERATURE CONTROLLER SYSTEMMULTIROOM TEMPERATURE CONTROLLER SYSTEMMULTIROOM TEMPERATURE CONTROLLER SYSTEM
Up to 32 sensors per controller
Up to 7 zones
Up to 31 program instructions can be saved per sensor or zone
Program types :
day programs
working day programs
weekend programs
week programs
Power supply: 12VDC ... 18VDC/50mA
VMB1TC
VMB1TC
VMB1TC
VMB1TSVMB1TSVMB1TS
VMB1TCW
VMB1TCW
VMB1TCW
VMB1TSWVMB1TSWVMB1TSW

There are several manuals available for
this temperature control system:
1. Getting started manual, This guide can be
found in the sensor package, and provides
an overview of the system. Read this first!
2. This manual, use it together with the getting
started manual for standard system set-up.
3. An extended manual is available for down-
load. Use this manual for special features
and to study examples.
4. A controller menu overview sheet is also
available for download, used as reference.
IMPORTANT: VMB1TS(W) and VMB1TC(W) modules
have the unique feature of user firmware update!
Due to the large amount of applications, check our
web site for manual updates and firmware updates.
Updates can add or improve functionality, not de-
scribed in these manuals.
Your current firmware version can be checked using
the Velbuslink PC software.

In this manual:
1. How to connect the temperature controller p.4
2. How to connect the temperature sensor p.5
3. Setting the address for sensor and controller p.6
4. Assign a relay channel to a temperature sensor function p.7
5. Set the menu language on the controller p.8
6. Setting the clock for the controller p.9
7. How to set up the sensor with the controller p.10
8. Operating the temperature controller p.12
9. Programming the temperature controller p.16
10. Screen & LED indicators p.21
11. Controller menu overview p.22

4
1. Temperature controller 'VMB1TC' connection
Connection Battery backup
To avoid losing the clock when a power failure occurs, a
backup battery (3V Lithium CR2032) can be installed in the
battery holder at the back of the module.
To avoid premature depletion of the battery, only install it
when permanent power is supplied to the Velbus system.
ENGLISH
9
Place the TERM jumper if the module is
connected at the start or end of a cable on the
Velbus.
Remove the jumper in all other cases. Place a jumper on the
end module of the longest cable only, NOT on each end point.
E.g. a normal two-story house will have 3 terminators: 1 up-
stairs end point, 1 downstairs end point and 1 in the fuse box.
9

5
2. Temperature sensor 'VMB1TS' connection and button+indicators overview
ENGLISH
BUS TWISTED PAIR (0.5mm²)
14
15
8
9
1
2
3
4
5
6 7
10 11 12 13
LED indication Settings
1Cooling mode 8Address setting*
2Comfort mode 9Terminator
3Day mode
4Night mode Wiring
5Heating or air-conditioning on 14 power supply 12 to 18Vdc
15 Velbus
Sensor
6Temperature sensor
Controls
7Mode pushbutton
7+11 Assign high temperature alarm*
7+12 Assign low temperature alarm*
7+13 Assign circulation pump*
10 Assign airco (COOL)*
11 Assign day setup for Central heating (DAY)*
12 Assign extra fan for boost heat (BOOST)*
13 Assign heater (HEAT)*
* only available for the VMB1TS module

6
ENGLISH
3. Address selection
In order to identify each module in your system it is necessary to set an unique address for each module.
This address will also be used by the PC software to scan all the addresses and to identify the modules.
0
1
Example of a valid address: “0 1”
1. Press and HOLD the ‘Menu’ button to open the extended menu.
2. Scroll through the extended menu using
↑
or
↓
buttons until the ‘’Configuration”
menu appears, select using the
→
button.
3. Scroll through the Configuration menu using
↑
or
↓
buttons until the ‘’Address”
menu appears
4. Select the Address menu using the
→
button.
5. Enter a unique address (‘01’...‘FE’) using the
↑
or
↓
button.
6. Confirm the address using the
→
button.
7. Exit the menu using the
button.
VMB1TC : ADDRESS SETTING USING THE MENU
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
3 421
6 7
5
Each module on the Velbus system must have its own unique
address, write down the address for later use!
VMB1TSW / VMB1TCW
VMB1TS : ADDRESS SETTING USING THE 2 ADDR ROTARY SWITCHES.
CAUTION: Addresses 81,91,A1, B1, C1, D1, E1, F1 & FF can NOT be used. Examples of valid
addresses: 01, 02, 03…. 0A, 0B…, 1A, 1B…
A total of 248 valid addresses can be selected for this module.
Adress setting trough Velbuslink©

7
ENGLISH
4. Assign a relay channel to a temperature sensor function (can also be performed using PC, advised)
On the sensor module:
Set the sensor module in anti-freeze mode by pressing the push button on the front panel repeatedly until all LED’s are off.
On the relay module:
ModeTime1
ADDR
First remember the address of the
module to reinstate it later on. Set the
Address rotary switches to 'C1', 'C2',
'C3, or 'C4', depending on the chosen
channel. The 'MODE' LED of that
channel will flash to indicate learning
mode.
Set the MODE and TIME1 rotary switches of the
chosen channel to
'0' (instant control)
Only available for VMB1TS
Select one of the below functions: (ask someone to help if needed)
To assign a room heater or room water valve to a relay contact (>> this will mostly be used)
Press button 13 on the sensor until relay engages
To assign the air-conditioning system (fan or compressor control) to a relay contact:
Press button 10 on the sensor until relay engages.
To assign the central heating system day/night setting to a relay contact:
Press button 11on the sensor until relay engages.
To assign an extra fan for quick heating or cooling (boost) to a relay contact:
Press button 12 on the sensor until relay engages
To assign the central heating system main pump to a relay contact
Press button 7+ button 13 on the sensor until relay engages
To assign a low temperature alarm to a relay contact
Press button 7+ button 12 on the sensor until relay engages
To assign a high temperature alarm to a relay contact
Press button 7+ button 11 on the sensor until relay engages
7
10 11 12 13
Do not forget to set the address of the
relay module back to its original value.
Repeat the procedure for other sen-
sors or other functions.

8
ENGLISH
5. Set the menu language on the controller
1. When applying power to the controller for the
first time, only the time is shown on the display.
2. Press and HOLD the ‘Menu’ button to open the
extended menu. Scroll to “Configuration” menu
using the ↑or ↓buttons. Confirm using the →
button.
3. Enter the language menu using the →button.
4. Choose the desired language using the ↑or ↓
buttons.
5. Confirm the language selection using the →button.
6. Exit the menu using the button.
1
2
3
4
5
6
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
See display & menu overview on page 21 & 22

9
6. Setting the clock
ENGLISH
It is important to set the correct time for the internal clock.
Setting the time on this module will synchronise all clocks in your Velbus system.
1
3
4
2 5
When applying power to the controller for the first time,
only the time is shown on the display.
1. Open the “short” menu by pressing the ‘Menu’ button.
2. Scroll to "clock set" menu using ↑or ↓buttons.
3. Select the set clock menu using the →button. The day-
indication flashes.
Set the day using ↑or ↓buttons.
Confirm using the →button. The hour-indication flashes.
Set the hour using ↑or ↓buttons.
Confirm using the →button. The minutes-indication flashes
Set the minutes using ↑or ↓buttons.
4. Confirm using the →button to start the clock from the set
time.
5. Exit the menu using the button.
See display & menu overview on page 21 & 22
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑

10
7. Sensors setup
ENGLISH
Before the controller can work with the temperature sensors it must first scan the network for all connected sensors.
If temperature sensors are installed or removed afterwards, the search process must be repeated to update the list of
sensors to the new situation. NOTE: Make sure "all rooms" or "zone" is not selected.
1. Press and HOLD the ‘Menu’ button to open the extended menu.
Scroll through the extended menu using ↑or ↓buttons until the
‘Configuration’ menu appears. Select the configuration menu
using the →button.
2. Scroll through the Configuration menu using ↑or ↓buttons until
the ‘Scan sensors’ item appears.
3. Confirm the scan sensors menu using the →button.
The search for sensors on the network is now in progress.
4. Once the search process is completed, the first of the connected
temperature sensors is shown on the display.
Searching for temperature sensors
1
2
3
4
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Andere Velleman Temperaturregler Handbücher
Beliebte Temperaturregler Handbücher anderer Marken

Swegon
Swegon LUNAd MB Bedienungsanleitung

Lucky Reptile
Lucky Reptile Thermo Control II Bedienungsanleitung

SENSORMETRIX
SENSORMETRIX Argon 100 Bedienungsanleitung

Fuji Electric
Fuji Electric PXE4 Bedienungsanleitung

Yuyao gongyi
Yuyao gongyi XMT-808 series Bedienungsanleitung

Selec
Selec TC544C Bedienungsanleitung