Vertilux VTi 6-800-MB-25B01 Betriebsanleitung

vertilux.comvertilux.com
Applies to Item Numbers:
ENGLISH
VTi®RE-LION MOTORS
Wire-free
Rechargeable
Battery Powered
6-800-MB-25B01 1Nm | Bidirectional
6-800-MB-25U01 1Nm | Unidirectional
6-800-MB-25B02 2Nm | Bidirectional
6-800-MB-25U02 2Nm | Unidirectional
6-800-MB-35B03 3Nm | Bidirectional
6-800-MB-35U03 3Nm | Unidirectional
6-800-MB-35B06 6Nm | Bidirectional
6-800-MB-35U06 6Nm | Unidirectional
ENGLISH
ESPAÑOL | PAG. 12
PROGRAMMING MANUAL
MANUAL DE PROGRAMACIÓN

01
vertilux.com
Important instructions and information
VTi Re-lion Motors. Reliable,
Powerfull and Quiet
Bidirectional communication allows getting information about the shade
position*.
3 Adjustable Speed control**.
Smooth and soft start and stop function.
Roller and jog mode operation.
Intermediate or favorite position.
Compatible with leading brands of Home automation systems and voice
command assistants.
*Available in bidirectional models.
Ensure that the motor is compatible with the associated brackets or
accessories. Incorrect installation can lead to serious injury and will void
manufacturer’s liability and warranty.
Do not expose to water, moisture, humid or extreme temperatures.
Do not lift the motor by grabbing the wire or antenna. Do not cut the
antenna.
This motor has a 12V built-in rechargeable Li-ion battery pack with
integrated charge management. Max input voltage: 5V/2A.
Please charge it before using for the first time, make sure it is fully
charged before first use.
Please do not use motor when charging.
When the battery voltage is low, LED will flicker 8 times to give a low
voltage alarm when motor starts. When the battery is fully charged, LED
on the motor head will remain solid blue.
1.
2.
3.
4.
5.
6.
7.

Product Information
© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023.
02 vertilux.com
Motor Head
Function Achieved
Motor runs to its limit or stop
if it is running
Motor limits must be already set
and the sleep mode inactive
Short press None
Sleep mode active
Sleep mode inactive
Reverse Direction
Reset
H Button Operation Motor Reaction Notes
Hold for 3s-
release-hold for 3s
Hold for 3s
Hold for 10s
Jogs x2 & LED
blink(orange) x1-
jogs x2 & LED
blink(orange) x2
RF control will be inactive
Motor will response to RF
control
Motor runs in the opposite
direction
Hold for 16s LED blink (orange)
x4-jogs x4
LED blink (orange)
x4-jogs x3
LED blink (orange)
x4-jogs x1
Reset the motor to factory
settings
QUICK ACCESS TO H BUTTON FUNCTIONS
Models:
6-800-MB-25B01 1Nm | Bidirectional
6-800-MB-25U01 1Nm | Unidirectional
6-800-MB-25B02 2Nm | Bidirectional
6-800-MB-25U02 2Nm | Unidirectional
Models:
6-800-MB-35B03 3Nm | Bidirectional
6-800-MB-35U03 3Nm | Unidirectional
6-800-MB-35B06 6Nm | Bidirectional
6-800-MB-35U06 6Nm | Unidirectional
RF
Antenna
USB-C
LED
Indicator
H Button
LED
Indicator
USB-C
RF
Antenna
H Button
Remote Control Options
6-800-AT-ESBT6
ESCALATE
6CH Timer Display
6-800-AT-ESB16
ESCALATE
16CH Display
3V
(CR2450)
+
CR2450
CR2450
LITHIUMBATTERY
3V
+
T
Button P
Button
6-800-AT-CHB02
CHIC 2CH LED
6-800-AT-CHB06
CHIC 6CH LED
FAV
Button
Display
Bidirctionls/Unidirctionls. Ths modls r st for bidirctionl communiction by fctory
dfult. Rfr to th function ''Stting bidirctionl/unidirctionl mod on th rmot'' to chng th
communiction mod nd mk th rmot only comptibl with unidirctionl motors.
In addition to the individual channels, it is also
possible in these remotes to program up to 6
channel groups, which enable multiple
channels to operate simultaneously. When you
are in a channel group the icon is shown on
the display.
Motor Battery
Level
Bidirectional Mode On
Lock Mode On
Channel
Groups
Remote Battery
Level
Motor Battery
Level
Bidirectional
Mode On
Channel
Groups
Remote Battery
Level
Lock Mode On

© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023. 03
vertilux.com
6-800-AT-POU02
POINT 2CH LED
6-800-AT-POU06
POINT 6CH LED
6-800-AT-POU16
POINT 16CH
+
+
+
+
AAA x2
FAV
Button
T
Button P
Button
Unidirctionls. Ths modls r only comptibl with
unidirctionl motors.
Pairing the Motor with the Remote
*Make sure you are not in a group channel.
You are in a group channel when all the leds are light on or the display show the number 0 for models without display. For
models with display you are in a group channel when the icon is shown on the display.
Setting Bidirectional/Unidirectional mode on the remote
The following procedure activate or deactivate the bidirectional function on the
remote. When the bidirectional mode is activated, the icon will be shown on the
display and the remote can’t be paired with unidirectional motors. Please note the
remote can be compatible with bidirectional or unidirecional motors but not with both
at the same time. Unidirectional and bidirectional motors can not be paired with the
same remote.
Please check if you have a bidirectional or unidirectional motor and set the remote
accordingly.
Only the following models can be compatible with bidirectional or unidirectional motors.
6-800-AT-CHB02, 6-800-AT-CHB06, 6-800-AT-ESBT6, 6-800-AT-ESB16
Stop Stop
Remove the
battery
Reinstall the
battery
PRESS & HOLD RELEASE
Jog x1 Jog x2
Motor Paired
Button
H button
Remove the battery from the remote
Press and hold the STOP button
Reinstall the battery
Release the stop button
1.
2.
3.
4.
Select the desired channel on the remote and press the H button on the motor
head until the motor jogs*.
Press P button on the remote. The motor will jog twice.
(Repeat the same procedure to unpair the motor from the channel selected)

© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023.
04 vertilux.com
Upper Limit Set
Up or Down Desired
Upper Limit
Up & Fav x2s Jog x2
Setting the Upper Limit
Reversing the direction of rotation (if needed)
Direction reversed
Up or Down x6 Jog x1
Lower Limit Set
Up or Down Desired
Lower Limit
Down & Fav x2s Jog x2
Setting the Lower Limit
By default, the motors are set to be installed on the right side. If required, please reverse
their direction.
1.
2.
1.
2.
1.
Adjusting Upper or Lower Limits
Up or Down
New Limit Set
Jog x2
Jog x1 New Limit
Position
Current Limit
Position
Up or Down & Fav
Up or Down & Fav x2s
1.
2.
3.
4.
Move the shade to the previously set upper or lower limit position by using
the remote control.
Press the UP and FAV buttons at the same time (to modify the upper limit)
or DOWN and FAV buttons at the same time (to modify the lower limit) until
the shade jogs once.
Move the shade to the new upper or lower limit position.
Press UP (for the upper limit) or DOWN (for the lower limit) and FAV
buttons at the same time for about 2s until the shade jogs twice.

© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023. 05
vertilux.com
Deleting all Limits
Jog x1 Jog x1 Jog x1Stop
Limits
Deleted
Button Button
1.
2.
3.
Deleting the Favorite Position
Favorite Position Deleted
Fav & Stop x2s
Shade is at
Favorite Position
Jog x1
Favorite position can only be set if the lower and upper limits were previously set. Press the
Favorite Button to move the shade up to the favorite position once it is set.
Fav
Setting the Favorite Position
Desired Favorite
Position Fav & Stop x2s Jog x2
Favorite Position Set
1.
2.
Adjusting the Motor Speed
Press the P button on the back of the remote until the shade jogs once.
Press the STOP button until the shade jogs once.
1.
2.
Increasing the Motor Speed
Within 3 seconds of Step 2, press the UP button. The shade will jog and the motor
will increase its speed. If the shade does not jog, the maximum speed is already set.
3a.
There are 3 speeds to choose from: Slow, Medium, and Fast. The higher the speed, the louder the motor. The default motor
speed is the medium speed.
Decreasing the Motor Speed
Within 3 seconds of Step 2, press the DOWN button. The shade will jog and the motor
will decrease its speed. If the shade does not jog, the lowest speed was already set.
3b.
Speed Increased
Down
Up
Jog x1 Jog x1Stop Speed Decreased
Button

© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023.
06 vertilux.com
Setting ON/OFF Jog or Roller mode
Repeat the same steps to deactivate the jog mode. When the jog mode have been set, the up or down
button must be pressed for 3s to make the motor move continually to its limits.
Jog x1 Jog x1Stop Jog x1Stop
Jog mode
ON/OFF
Button
1.
2.
Sleep Mode ON
Setting ON/OFF ”Sleep” Mode
Jog x1
x3s x3s Jog x1
Motor is now in “Sleep” Mode
Setting the motor in smart connection mode
Download the VTi HomeMate+ app on AppStore or Google Play and follow the steps in the app until it
ask you to set the motor in smart connection mode. Then, follow the procedure below. Refer to VTi
RE-LION SmartHub PLUS user manual for more details.
H
Button Smart Connection
mode is ON
Jog x1 Jog x1
Hold x6s
Vti HomeMate+
H button H button
1.
2.
1.

© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023. 07
vertilux.com
Sleep Mode OFF
Press and hold the H button on the motor head for 3 seconds until the motor jogs once, then
release it.
Jog x1
x3s
Motor is now “Awake”
When a group of motors are paired on a single channel, set the Sleep Mode ON to all motors except
the one that you would like to program or adjust the setting. Wake up all the motors once you finish
programming the motor that remained ‘’awake’’.
Adding or deleting to a different Remote or Channel using
an already programmed Remote or Channel.
Jog x1Jog x1 Jog x1
Stop
Remote/
Channel A Remote/
Channel A
Remote/
Channel B
Remote or
Channel B is now
Added/Deleted
Button Button
H button
Unpairing a Motor (s) from all Remotes
Jog x1Jog x1 Jog x1
Motor(s) Unpaired
from all Remotes
Button Button
1.
2.
3.
Down

© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023.
08 vertilux.com
Turn ON/OFF Motor Charging Led
The led on the motor head will blink 3 times every 8 seconds when the battery is low. Once
the charger is connected, the LED will blink 6 times during the charging time. The LED turns
solid blue when the battery is fully charged. Turning OFF the charging LED is recommended
when motors are powered by solar panels.
Resetting the Motor to Factory Settings
Press and Hold the H button on the motor head for 16 seconds until the motor jogs four
times, then release it. All the motor settings will be deleted.
Factory
Settings
Jog x1 Jog x1 Jog x1 Jog x1
H button
Resetting the remote to factory settings
Press and hold the T and FAV buttons at the same for about 10 seconds. ( will be
shown if you have a remote with display).
PRESS x 10s
Reset
&
T
Button FAV
Button
1.
2.
3.
Models with Led Channel Indicator
Led no.6 will turn solid orange when you press any button.
Models with Display
The battery icon will be shown on the display when you press any button.
Remote Low Battery Notification
The remote shows a notification when its battery is below 2.7V DC
Moving the Shade to a Percentage Opening
The following functions are only available for Bidirectional Motors and Remotes
with Display. Applies to models: 6-800-AT-ESB16 & 6-800-AT-ESBT6
100% Shade completely close. 0% Shade completely open.

Hiding the Unused Channels
Only the desired quantity channels will be visible. Repeat the same procedure to set a new quantity
of active channels.
Make sure you are not in a channel group before the step no.1.
Adding Channels to Groups
Checking Channels added into the Groups
Disable Setting Functions (Lock mode)
A lock icon is displayed on the screen when the lock mode has been set. Under this mode,
dual-button operation is not allowed and the motor configuration can not be modified. This function
should be set once the motor programming is completed to avoid any unwanted configuration change.
Repeat the same procedure to unlock the setting function.
Hiding the Unused Groups
Only the desired quantity of groups will be visible. Repeat the same procedure to set a new
quantity of active groups.
© 2023. Vertilux, Ltd. All Rights Reser ved. Last revised: July 2023. 09
vertilux.com
Dieses Handbuch passt für folgende Modelle
7
Inhaltsverzeichnis
Sprachen:
Andere Vertilux Motor Handbücher