BEFORE USE THE REFRIGERATOR, PLEASE READ AND FOLLOW
ALL SAFETY RULES AND OPERATING INSTRUCTIONS.
Have product questions? Need technical support? Please feel free to
contact us: Technical Support and E-Warranty Certificate
www.vevor.com/support
NEED HELP? CONTACT US!
This is the original instruction, please read all manual instructions
carefully before operating. VEVOR reserves a clear interpretation of our
user manual. The appearance of the product shall be subject to the
product you received. Please forgive us that we won't inform you again if
there are any technology or software updates on our product.
CHAINSAW
SHARPENER JIG KIT

- 2 -
Warning-To reduce the risk of injury, user must read
instructions manual carefully.
SPECIFICATIONS
Model
BC-145WS
BC-145WD
BCD-145WD
Voltage /
Frequency
AC115V 60Hz
AC115V 60Hz
AC115V 60Hz
Amperage
1.0A
1.0A
1.0A
Product
Type
Service Fridge
Service Fridge
Service Fridge
Freezer
Input Power
87W
87W
87W
Capacity
145L(UP:74L,
Down:71L)
138L(UP:16 bottles
Red Wine
,Down:68.5L)
138L(UP:69.5L,
Down:68.5L)
Refrigerant
R600a
37g
R600a
37g
R600a
45g
T° zone
Zone T°
1~10℃
34~50°F
UP 5~22℃
UP 41~72°F
DN 1~5℃
DN 34~41°F
UP 3~10℃
UP 37~50°F
DN -18~3℃
DN 0~37°F
(Width x
Depth x
Height)
23.5’ x 22’ x
32.2’~34.2’
595 x 560 x
820~870mm
23.5’ x 22’ x
32.2’~34.2’
595 x 560 x
820~870mm
23.5’ x 22’ x
32.2’~34.2’
595 x 560 x
820~870mm

- 3 -
IMPORTANT SAFETY RULES
Before the appliance is used, it must be properly positioned and installed as
described in this manual, so read the manual carefully. To reduce the risk of fire,
electrical shock or injury when using the appliance, follow basic precaution,
including the following:
·Read all instructions before using the refrigerator.
·Plug into a grounded 3-prong outlet, do not remove grounding prong, do not
use an adapter, and do not use an extension cord.
·Replace all panels before operating.
·It is recommended that a separate circuit, serving only your appliance be
provided. Use an outlet that cannot be turned off by a switch.
·Never clean appliance parts with flammable fluids. These fumes can create a
fire hazard or explosion. And do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any other appliance. The fumes can
create a fire hazard or explosion.
·Before proceeding with cleaning and maintenance operations, make sure the
power line of the unit is disconnected.
·Do not connect or disconnect the electric plug when your hands are wet.
·Unplug the appliance or disconnect power before cleaning or servicing. Failure
to do so can result in electrical shock or death.
·Do not attempt to repair or replace any part of your appliance unless it is
specifically recommended in this material. All other servicing should be referred
to a qualified technician.
·To prevent a child from being entrapped, Keep out of reach of children and not
in the vicinity of refrigerator.
·Before you throw away your old refrigerator, take off the door but leave the

- 4 -
shelves in place so that children may not easily climb inside.
·Never allow children to operate, play with, or crawl inside the appliance.
·To ensure proper ventilation for your appliance, the front of the unit must be
completely unobstructed. Choose a well-ventilated area with temperatures
above 60°F (16°C) and below 90°F (32°C). This unit must be installed in an
area protected from the element, such as wind, rain, water spray or drips.
·The appliance should not be located next to ovens, grills or other sources of
high heat.
·The appliance must be installed with all electrical, water and drain connections
in accordance with state and local codes. A standard electrical supply (115 V
AC only, 60 Hz), properly grounded in accordance with the National Electrical
Code and local codes and ordinances is required.
·Do not kink or pinch the power supply cord of appliance.
·It is important for the appliance to be levelled in order to work properly. You may
need to make several adjustments to level it.
·Do not use solvent-based cleaning agents of abrasives on the interior. These
cleaners may damage or discolour the interior.
·Do not use this appliance for other than its intended purpose.
For your safety observe the following recommendations.
·This appliance contains a small quantity of R600a refrigerant which is
environmentally friendly, but flammable. It does not damage the ozone layer,
nor does it increase the greenhouse effect.
·During transportation and installation, ensure that the tubing of the refrigerant
circuit is not damaged.
·when handling, moving and use of the refrigerator or freezer to avoid either
damaging the refrigerant tubing or increasing the risk of a leak.
·Avoid using or manipulating sharp objects near by the appliances.
·Leaking refrigerant can ignite and may damage the eyes.
·In the event any damage does occur, avoid exposure to open fires and any
device which creates a spark. Disconnect the appliance from the mains
FLAMMABLE REFRIGERANT

- 5 -
power.
·Thoroughly ventilate the room in which the appliance is located for several
minutes.
·Notify Customer Service for necessary action and advice.
·The room for installing the appliance must be at least 1 cubic metre per 8
grams of refrigerant. The refrigerant quantity contained in this appliance is
listed above in grams; it is also noted on the Rating Plate of the appliance.
PARTS AND FEATURES
BC-145WS & BCD-145WD

- 6 -
BC-145WD
PREPARATION AND INSTALLATION
Preparation
—Allow 24 hours before switching on the refrigerator. During this time we
recommend that you leave the door open to clear any residual odors.
—The location you have selected for your refrigerator should:
·Be unencumbered and well ventilated
·Be well away from any heat source and direct sunlight
·Not be too damp (laundry, pantry, bathroom etc.)
·Have a flat floor
·Have a standard and reliable electricity supply (standard socket to country
standards, linked to the ground), it is not recommended to use a multi-socket or
extension lead
·Have a surge protector fitted to the electrical outlet
·Away from the microwave oven. Certain microwave ovens do not have wave
interference shield. When placed within 1 meter vicinity of the wine cabinet,
they may affect the operation of the refrigerator.

- 7 -
·Avoid locating the unit in moist areas, like a garage.
—The unit should be placed where the ambient temperature is proper. If the
temperature is above or below this range, it will affect the performance of the unit.
Placing in cold or hot temperature conditions may cause cellar's temperatures
fluctuating, and it will not reach the ideal one.
Installation
—Read the instruction manual.
—Unpack and remove all of the protection and adhesive strips from the
packaging around and inside the refrigerator.
—The refrigerator must be positioned such that the plug is accessible. Release
the power cord. Move your refrigerator to its final location. The refrigerator should
be installed in a suitable place where the compressor will not be subject to
physical contact.
—Leveling your refrigerator: Units must be leveled before loading your drinks.
The unit is equipped with 4 adjustable feet to facilitate easy leveling. It’s
recommended that you tighten the back feet to the maximum and adjust the front
feet to level the unit.
Built-in Instructions
—“built-in” refrigerators and beverage centers are front venting but are not
designed to be fully integrated behind a joinery door.
—Please follow the installation diagram when installing a built-in unit. No less
than the minimum installation dimension or it will affect the venting of refrigerator.

- 8 -
—“built-in” units draw air from right of ventilation frame and expel through left of
ventilation frame under the front door.
—“built-in” refrigerators and beverage centers have a power switch located on
the control panel so power point location is not critical.
—The unit requires a standard 120 volt power point.
—The power cord is 1 m in length and is fixed on the right side at the back when
looking from front of refrigerator.
—As with most appliances of today, the refrigerator has sensitive electronic
components which are susceptible to damage through lightning and electricity
supply faults. It is therefore advised to use a power surge protector to avoid
problems of this nature.
—Air vent on door must be provided for any built-in wine unit when a wood door is
installed in front of the unit.
Electrical Connection
Improper use of the grounded plug can result in the risk of electrical shock. If the
power cord is damaged, have it replaced by an authorized service center.
This appliance should be properly grounded for your safety. The power cord of

- 9 -
this appliance is equipped with a three-prong plug which mates with standard
three prong wall outlets to minimize the possibility of electrical shock.
Do not under any circumstances cut or remove the third ground prong from the
power cord supplied. For personal safety, this appliance must be properly
grounded.
This appliance requires a standard 115/120 Volt AC ~/60Hz electrical ground outlet
with three-prong. Have the wall outlet and circuit checked by a qualified electrician
to make sure the outlet is properly grounded. When a standard 2-prong wall outlet
is encountered, it is your responsibility and obligation to have it replaced with a
properly grounded 3-prong wall outlet. The cord should be secured behind the
appliance and not left exposed or dangling to prevent accidental injury.
The appliance should always be plugged into its own individual electrical outlet
which has a voltage rating that matches the rating label on the appliance. This
provides the best performance and also prevent overloading house wiring circuits
that could cause a fire hazard from overheated. Never unplug the appliance by
pulling the power cord. Always grip the plug firmly and pull straight out from the
receptacle. Repair or replace immediately all power cords that have become
frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion
damage along its length or at either end. When moving the appliance, be careful
not to damage the power cord.
Extension Cord
Because of potential safety hazards under certain conditions, it is strongly
recommended that you do not use an extension cord with this appliance. However,
if you must use an extension cord it is absolutely necessary that it be a
UL/CUL-Listed, 3-wire grounding type appliance extension cord having a
grounding type plug and outlet and that the electrical rating of the cord be 115 volts
and at least 10 amperes.
OPERATING THE UNIT
Initial Use
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere VEVOR Gefrierschrank Handbücher