FFrreeeessttaannddiinnggBBoottttoommMMoouunntt//FFrreenncchhDDoooorrBBoottttoommMMoouunntt
DDEESSCCRRIIPPTTIIOONNVVCC//DDDDBBFF//VVCC//DDDDFFFF
Overall Width 35 5/8” (90.5 cm)
Addition of side panels: 35 7/8” (91.1 cm)
Overall Height from Bottom 70 1/8” (178.1 cm)
Addition of tops/grilles: 71 7/8” (182.6 cm)
Overall Depth from Rear To front of door: 26 3/4” (67.9 cm)
Cutout Width 36” (91.4 cm)
Cutout Height 70 1/2” (179.0 cm)
Addition of tops/grilles 72” (182.9 cm)
Cutout Depth 24” (61.0 cm)
Electrical Requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong
plug attached to product.
Maximum Amp Usage 7.9 amps
Inlet Water Requirements 1/4” copper tubing inlet waterline; minimum 35 psi; maximum 100 psi
Overall Interior Capacities Bottom Mount French Door Bottom Mount
•Refrigerator 14.4 cu. ft. (407 liters) 14.1 cu. ft. (399 liters)
•Freezer 5.5 cu. ft. (156 liters) 5.5 cu. ft. (156 liters)
•Total Capacity 19.9 cu. ft. (563 liters) 19.6 cu. ft. (555 liters)
Approximate Shipping Weight 327 lbs. (148.7 kg)
DANGER
RRiisskkooffCChhiillddEEnnttrraappmmeenntt
BBEEFFOORREEYYOOUUTTHHRROOWWAAWWAAYYYYOOUURROOLLDD
RREEFFRRIIGGEERRAATTOORROORRFFRREEEEZZEERR::
•Take off the doors.
•Leave the shelves in place so that children
may not easily climb inside.
IIMMPPOORRTTAANNTT::Child entrapment and
suffocation are not problems of the past.
Junked or abandoned refrigerators are still
dangerous... even if they will sit for “just a few
days.”
IIttiisstthheeccuussttoommeerr’’ssrreessppoonnssiibbiilliittyyttoo::
•contact a qualified electrical installer.
•assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes
and ordinances. (115 volt, 60-Hz, 15 amp, fused, electrical supply is required. It is required that a separate circuit
serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong
grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-
type wall receptacle. If a 2-prong receptacle is encountered, the customer must contact a qualified electrical installer
to have it replaced with a properly grounded 3-prong receptacle. Do not use an extension cord or adapter plug.)
EELLEECCTTRRIICCAALLSSHHOOCCKKHHAAZZAARRDD
PPlluuggiinnttooaaggrroouunnddeedd33--pprroonnggoouuttlleett..
DDOONNOOTTrreemmoovveeggrroouunnddpplluugg..
DDOONNOOTTuusseeaannaaddaapptteerr..
DDOONNOOTTuusseeaanneexxtteennssiioonnccoorrdd..
FFaaiilluurreettooffoolllloowwtthheesseeiinnssttrruuccttiioonnss
ccoouullddrreessuullttiinnffiirreeoorreelleeccttrriiccaallsshhoocckk..
WARNING
Power cord with 3-prong
grounding plug
Grounding-type wall
receptacle
**WWhheenniinnssttaalllliinnggiinnttooaaccuuttoouutt,,tthheeeeddggeeoofftthheeddoooorrmmuussttbbee2277//88””((77..33ccmm))ffrroommtthheeaaddjjaacceennttccoouunntteerrttooppccaabbiinneett..