Villa ADIME904-04 Bedienungsanleitung

STAINLESS STEEL
VETERINARY SCALE
USER GUIDE
ADIME904-04

Thank you
for your
purchase.
Viva Comfort maintains a
strong practice of ongoing
development of products and
commercial research.
We recognize that starting and maintaining a medical
practice is expensive. We’ll help make the process cost-
eective and elegant. Additionally, our team of specialists
will ensure everything you need works as eciently as
possible, so you can eectively treat your clients.

Table of Contents
2
3
4
12
12
13
Parts List
Button Functions
Operational Method
Malfunction
Specication
Warranty

2
Parts List
A. Base
B. Indicator
A
B

3
Button Functions
ON/OFF
UNIT
HOLD/
PRINT
TARE
Name
Turn on/off Null
Scroll down the menu
or parameters
Scroll up the menu or
parameters
Enter the menu or
conrm to change
parameter.
O
U
H
T
Switch the unit
Hold Function/
Output Printing
Tare
Function Menu Function Serial Port
Instruction
Code

4
Installing the Power Adapter:
Loading The Batteries:
Turn On:
Turn Off:
Weighing:
A. Insert the plug of the AC Adapter into the supply hub located
on the left of the display indicator.
B. Insert the AC Adapter into the AC socket.
A. Open the battery cover located on the right side of the display
indicator, load four AAA alkaline cells into the cell box.
a. Pay close attention to the polarities of the alkaline cells.
b. Close the battery cover once successfully installed.
A. First, make sure nothing is on the scale before powering it on.
B. Press the “On/Off” button; it will show all the characters and
then all the versions of numbers.
C. After the screen displays a “0”, you can begin to weigh
objects/animals.
A. Press the “On/Off” button once to turn off the scale.
A. To begin weighing, ensure your scale is on.
B. Press the “Tare” button once to make the indicator display a “0”.
C. Put the object/animal in the middle of the scale platform.
a. After the kg., lb., or pcs. character stops ashing, you can
begin to read the weight.
Operational Method:

5
Calibration - Single Point:
A. To calibrate, press the hold the “UNIT” button until the window
displays “------.“
B. Press the “UNIT” or “HOLD” button to switch functions and make
the window display “CAL.”
C. Press the “TARE” button to ensure you enter calibration mode.
D. Once you’ve entered calibration mode, the window will display
“Load” and “0.0 kg” alternately.
a. This means that the weight “0.0 kg” should be loaded on the
platform.
E. After making sure that there is nothing on the platform, press the
“TARE” button to conrm.
a. This way, the scale begins at a “0.0 kg” calibration.
b. In the process of “0.0 kg” calibration, the “0.0 kg” will icker
rapidly on the display window.
i. Do not touch, nudge, or press anything to the scales
platform at this point.
c. If the scale remains stable for over 2 seconds, the scale will
nish the “0.0 kg” calibration automatically and continue with
the next calibration.
d. If the “0.0 kg” continues to icker, it is waiting until there is a
stable weight.
F. Suppose that the next calibration point should be “xx.x kg” the
window will display “LOAD” and “xx.x kg” alternately, which
means that the weight “xx.x kg” should be loaded onto the
platform.

6
Calibration - Single Point:
G. If you have to change this weight, you can short-press the
“UNIT” button or the “HOLD” button to enter the modied
menu.
a. Press the “UNIT” button to change the ashing position and
then press the “HOLD” button to make the ashing position’s
number plus 1.
b. Press the “TARE” button to make sure the modication is
nished.
H. After making sure the weight on the platform is “xx.x kg”, press
the “TARE” button to conrm so that the scale begins the
“xx.x kg” calibration.
I. While calibrating, the “xx.x kg” will icker rapidly on the display
window.
a. Do not touch, nudge, or press anything to the scales
platform at this point.
b. If the scale remains stable for over 2 seconds, the scale
will nish the “0.0 kg” calibration automatically and continue
with the next calibration.
c. If the “0.0 kg” continues to icker, it is waiting until there is a
stable weight.
Changing The Unit:
A. Press the “UNIT” button to switch the weighing units between
kg., lb., pcs.

7
Hold Function:
Animal Weighing:
A. When the “HOLD” button is pressed the following occurs:
a. The CPU will send weight data into the USB or RS232
socket.
b. The weight will remain on the display for 120 seconds after
the item has been removed from the scale so that the weight
can be easily read.
B. Place an item on the scale platform.
a. Wait for the stable weights to be displayed.
b. Press the “HOLD” button and “ ” will display.
c. Remove the object from the platform; the weight reading
will remain on the display for 120 seconds.
d. To exit the hold, once the item is weighted and the hold
function has been enabled, press the “HOLD” button again.
i. This will cancel the “ ” hold indicator and return the
scale to the weight value.
A. When the machine is on, press and hold the “TARE” button
until it displays either “OFF” or “ON”.
a. This means open or close the function of animal weighing.
B. When the action symbol, located above the until symbol,
begins to ash, this will indicate the current model is animal
mode.
a. Once the weighing is locked, it will automatically remain at
the locked weight for about 10 seconds.

8
Counting Sample:
A. When trying to count, remove unrelated objects on the
platform, and then press the “TARE’ button to go back to zero.
B. Press the “UNIT” button to switch the unit to “PCS”, and the
window will display “ADD10”.
a. “ADD10” means that 10 objects that need to be weighed,
should be added to the platform.
b. The weight of each sample should be higher than the
scale’s minimum division value.
i. If not, the window will display wrong cute “no”.
c. If you want to change the sampling quantity, press the
“HOLD” button to change the quantity.
i. If you don’t need to sample again, please press the
“UNIT” button to cancel the sampling and then the scale will
adopt the last sampling value to count.
C. After you conrm the quantity of the objects on the platform.
And the date displayed on the LCD are the same, press the
“TARE” button to conrm.
a. Then proceed with the sample and count.
D. During the process of sampling and counting, the screen will
display the sampling data accompanied by rapid ickering.
a. Do not touch, nudge, or press anything to the scale’s
platform at this point.
b. If the weighing remains stable exceeding 2 seconds, the
sampling and counting will automatically nish.
i. The parameter will be saved automatically and the
scale will return the counting mode.
c. If not, the screen will keep ickering the data until the scale
stabilizes.