Functions Configurable parameters
Monostable relay • 69PH identifier (see paragraph 4 “ID assignment”)
• Operating modes = “DEFAULT”
• Group 1 = 0
• Group 2 = 0
• Group 3 = 0
• Group 4 = 0
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Call-activated monostable relay • Operating modes = “Monost.Call Accept.”
• Enabling map = enable devices that send and receive the call (all enabled by default)
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Door lock command activated monos-
table relay
• Operating modes = “Monost. On SR”
• Enabling map = enable devices that send and receive the command (all enabled by default)
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Monostable relay activated by com-
mand F1
• Operating modes = “Monost. On F1”
• Enabling map = enable devices that send and receive the command (all enabled by default)
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Monostable relay activated by com-
mand F2
• Operating modes = “Monost. On F2”
• Enabling map = enable devices that send and receive the command (all enabled by default)
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Call attempt activated monostable relay • Operating modes = “Call Att.Enabl.Map”
• Enabling map = enable devices that send and receive the call (all enabled by default)
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Monostable relay activated by call at-
tempt to master unit
• Operating modes = “Call Att.to Group”
• Group 1 = ID indoor station
• Group 2 = ID indoor station
• Group 3 = ID indoor station
• Group 4 = ID indoor station
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Button-activated bistable relay • 69PH identifier (see paragraph 4 “ID assignment”)
• Operating modes = “Bistable”
• T1 activation delay time (def. 1s)
• T2 deactivation delay time (def. 1s)
• FLAG “State Not.” (YES = sends status with each switch, NO = does not send)
Bistable relay activated by accepted call. • Operating modes = “Bist.Accept.Call”
• Enabling map = enable devices that send and receive the command (all enabled by default)
• T1 activation delay time (def. 1s)
• T2 deactivation delay time (def. 1s)
• FLAG “Int.Call” (YES = Deactivates at end of call. NO = Deactivates on answering or, if external call, at end of electronic unit chime cycles)
Call repeater • Operating modes = “Default”
• Group 1 RL1 = Group 1 RL2 = ID indoor station
• Group 2 RL1 = Group 2 RL2 = ID indoor station
• Group 3 RL1 = Group 3 RL2 = ID indoor station
• Group 4 RL1 = Group 4 RL2 = ID indoor station
• “Chime cycles” = desired number of cycles
Generic call repeater • Operating modes = “Default”
• Group 1 RL1; Kind of call repeated for Group 1 RL1
• Group 2 RL1; Kind of call repeated for Group 2 RL1
• Group 3 RL1; Kind of call repeated for Group 3 RL1
• Group 4 RL1; Kind of call repeated for Group 4 RL1
• Group 1 RL2; Kind of call repeated for Group 1 RL2
• Group 2 RL2; Kind of call repeated for Group 2 RL2
• Group 3 RL2; Kind of call repeated for Group 3 RL2
• Group 4 RL2; Kind of call repeated for Group 4 RL2
• “Chime cycles” = desired number of cycles
N.B. For repetition of calls from 6120, the “landing group” flag of the called indoor station must be enabled.
Call repeater from 6120 • Operating modes = “Call Rep. 6120"
• Enabling map = enable devices that send and receive the call (all enabled by default)
• “Chime cycles” = desired number of cycles
Roller Shutter mode • Operating modes = “Roller Shutter Mode”
• T1 delay time (def. 1s)
• T2 activation time (def. 1s)
Call progression • Operating modes = “Call progression”
Table 6
7
EN
69PH