WarmFlow A Series Bedienungsanleitung

High Efficiency
Variable Speed
Air Source Heat Pumps
Models covered by this manual:
A-Series
Air Source AS01-R32 AS02-R32 AS03-R32
Incorporating: User Instructions
Installation Instructions
Service Instructions
Guarantee Terms & Conditions

INSTALLATION, COMMISSIONING & SERVICING
This appliance must be installed as described herein and the installation commissioned by
competent persons as instructed. The Installation/Commissioning Certificate supplied with the
product must be completed and returned to the manufacturer with proof of purchase (e.g. receipts
/ invoices).
This appliance must be serviced annually by competent persons, the Service Record completed
on each occasion and proof of servicing (e.g. receipts / invoices) retained.
The complete guarantee policy statement is included in Section 4.
FAILURE TO COMMISSION, REGISTER AND ANNUALLY SERVICE THIS
PRODUCT WILL INVALIDATE ALL GUARANTEES
TECHNICAL, SPARES & GUARANTEE CLAIMS
For technical advice about the installation, commissioning, servicing or use of this appliance,
please contact the Warmflow Customer Care Centre by post, phone, fax or email at the addresses
below. Please also refer to our website.
In the unlikely event that replacement components might be required within the guarantee period,
please notify the Customer Care Centre in writing, by post, fax or email, stating the nature of the
fault and the part number of the replacement components required.
Warmflow Customer Care Centre
Warmflow Engineering
Lissue Industrial Estate
Moira Road
Lisburn
BT28 2RF
Northern Ireland
Telephone
United Kingdom: 028 9262 1515
Republic of Ireland: 048 9262 1515
Facsimile
United Kingdom: 028 9262 0869
Republic of Ireland: 048 9262 0869
Email
Website
www.warmflow.co.uk

Page 1
CONTENTS
Contents ...................................................................................................................................................................... 1
1 USER INSTRUCTIONS ........................................................................................................................................ 3
1.1 Intended Use ................................................................................................................................................................. 3
1.2 Compliances ................................................................................................................................................................. 3
1.3 Basic Operation ............................................................................................................................................................. 3
1.4 Product Data ................................................................................................................................................................. 4
1.4.1 Starting Current ..................................................................................................................................... 6
1.5 Construction .................................................................................................................................................................. 7
1.6 Supplied Components ................................................................................................................................................... 7
1.7 Storage / Transport ....................................................................................................................................................... 8
2 USER INTERFACE .............................................................................................................................................. 9
2.1 Home Screen Icons ....................................................................................................................................................... 9
3 AIR SOURCE HEAT PUMP INSTALLATION ................................................................................................... 33
3.1 General ....................................................................................................................................................................... 33
3.2 Access ......................................................................................................................................................................... 35
3.3 Unpacking ................................................................................................................................................................... 35
3.4 Heating Circuit Connection .......................................................................................................................................... 36
3.4.1 Heating Medium .................................................................................................................................. 36
3.4.2 Heating Connections to the Heat Pump ............................................................................................. 36
3.4.3 Heating Circuit and Integrated Circulator............................................................................................ 36
3.4.4 Bypass / Open Zones ......................................................................................................................... 36
3.4.5 Freeze Protection ................................................................................................................................ 37
3.4.6 Heating Circuit Line Components ....................................................................................................... 37
3.5 Defrosting .................................................................................................................................................................... 39
3.6 Air Vent ....................................................................................................................................................................... 39
3.7 Buffer tank ................................................................................................................................................................... 39
3.8 Bypass Valve............................................................................................................................................................... 39
3.9 3-Port Motorised Valve ................................................................................................................................................ 40
3.10 Electrical Installation .................................................................................................................................................... 41
3.10.1 Incoming Supply ................................................................................................................................. 41
3.10.2 Digital Inputs ....................................................................................................................................... 41
3.10.3 Temperature Sensors ......................................................................................................................... 42
3.10.4 Digital Outputs .................................................................................................................................... 43
3.10.5 User Interface (Controller) .................................................................................................................. 44
3.10.6 DTU Module ........................................................................................................................................ 44
3.11 Parameter List ............................................................................................................................................................. 46
Commissioning ......................................................................................................................................................................... 51
3.11.1 Recorded Details ................................................................................................................................ 51
3.11.2 Testing Flow Rate ............................................................................................................................... 51
3.11.3 Weather Compensation Mode ............................................................................................................ 51
............................................................................................................................................................................ 52
3.11.4 DHW Cylinder Heat Up Test ............................................................................................................... 52
3.11.5 Sign Off ............................................................................................................................................... 53
3.12 System Hand Over ...................................................................................................................................................... 53
3.13 Servicing ..................................................................................................................................................................... 53

Page 2
3.13.1 Servicing Schedule ............................................................................................................................. 53
3.14 Alarms and Troubleshooting ....................................................................................................................................... 55
3.15 Alarms ......................................................................................................................................................................... 55
3.16 Troubleshooting........................................................................................................................................................... 61
4 YOUR GUARANTEES, TERMS & CONDITIONS ............................................................................................. 62
4.1 Period of Guarantee .................................................................................................................................................... 62
4.2 Warmflow’s Obligations ............................................................................................................................................... 62
4.3 Your Obligations .......................................................................................................................................................... 62
4.4 Exclusions of Guarantee ............................................................................................................................................. 63
4.4.1 Repairs ................................................................................................................................................ 63
4.4.2 Other property ..................................................................................................................................... 63
4.4.3 General ............................................................................................................................................... 63
5 End-of-Life Information .................................................................................................................................... 65
5.1 Safety Risks ................................................................................................................................................................ 65
5.2 Disassembly of the Product ......................................................................................................................................... 65
6 Appendix A: Tables for volume calculation. .................................................................................................. 67
7 Appendix B: Wiring Diagrams ......................................................................................................................... 68
8 APPLIANCE SERVICE RECORDS. .................................................................................................................. 73

Page 3
1 USER INSTRUCTIONS
1.1 Intended Use
The Warmflow Air Source Heat Pump units are intended for the production of hot water for space
heating and sanitary water. The units can be used to provide heating and domestic hot water
(DHW) via underfloor heating circuits, radiators and approved hot water cylinders. The units are
designed to extract heat from the air.
1.2 Compliances
The Warmflow AS01-R32, AS02-R32 and AS03-R32 air source heat pump units are
Microgeneration Certification Scheme (MCS) approved and hold both UKCA and CE markings.
They are approved on the Renewable Heat Incentive Eligibility list and can be found on both the
Product Characteristics Database (PCDB) as well as the Home-heating Appliance Register of
Performance (HARP) database. As such the units comply with the following directives and are
tested to the following standards:
MCS 007 Issue 3.0 - Product Certification Scheme Requirements: Heat Pumps.
2006/95/EC - Low Voltage Directive.
2004/108/EC - Electromagnetic Compatibility Directive.
97/23/EC - Pressure Equipment Directive.
EN14511 - Air conditioners, liquid chilling packages and heat pumps with electrically
driven compressors for space heating and cooling.
EN14825 - Air conditioners, liquid chilling packages and heat pumps, with electrically
driven compressors, for space heating and cooling. Testing and rating at part load
conditions and calculation of seasonal performance.
EN 60335-1 - Household and similar electrical appliances. Safety. General requirements.
EN 60335-2-40 - Household and similar electrical appliances. Safety. Particular
requirements for electrical heat pumps, air-conditioners and dehumidifiers.
EN 61000 - Electromagnetic compatibility (EMC). Limits.
EN 378 - Refrigerating systems and heat pumps. Safety and environmental
requirements.
ENV 12102 - Air conditioners, liquid chilling packages, heat pumps and dehumidifiers
with electrically driven compressors for space heating and cooling. Measurement of
airborne noise. Determination of the sound power level.
1.3 Basic Operation
Heat flows from an area of higher temperature to an area of lower temperature. In much the
same way that a water pump, pumps water from a low level to a higher level, a heat pump pumps
heat from a source at a low temperature to a source at a higher temperature. The benefit of this
is that natural sources such as the air and ground, which are at relatively low temperatures, can
be used to heat buildings at a higher temperature. In order to do this the heat pump uses a
relatively small amount of electrical energy. The proportion of electrical energy used to do this is
much smaller than the heat power delivered to the building. The ratio of the heat power delivered
to the electrical energy used determines the efficiency of the heat pump and is commonly known
as the coefficient of performance (COP).

Page 4
Heat is extracted from the air by blowing air through a finned radiator, known as the evaporator,
with a fan. The extracted energy from the air is transferred into the refrigerant which circulates
around the evaporator. The heat pump then converts this low grade heat to a high grade by
compressing the refrigerant using the compressor. The compression of the refrigerant increases
the pressure and the temperature. This high grade heat is then transferred to the heating system
via another heat exchanger known as the condenser. The heat can now be used to provide space
heating and DHW. The pressure of the refrigerant is then released through a throttling valve
known as the expansion valve which also causes the temperature to drop and allows the cycle to
start over again.
1.4 Product Data
Table 1 Product data
Product Data AS01-R32 AS02-R32 AS03-R32
Dimensions
(mm)
Width 1002 953 997
Depth 490 460 437
Height 805 915 1315
Weight (kg) 90 108 140
Electrical Supply 230V Single Phase
@50Hz
230V Single Phase
@50Hz
230V Single Phase
@50Hz
Maximum Current (Amps) 13 22 33
Nominal Sound Level (dBA)* 37 - 54 42 - 55 44 - 58
Performance
COP @ A7W35 4.58 4.35 4.67
COP @ A2W30 4.18 3.46 3.74
COP @ A7W27 6.10 5.76 5.37
COP @ A12W24 8.58 8.39 7.37
COP @ A-7W34 3.11 2.95 2.71
COP @ A7W55 2.68 2.67 2.51
COP @ A-10W55 1.90 1.69 1.94
Heat Output Range 2 - 8kW 5 - 12kW 7 - 20kW
ErP Efficiency Class
(35°C / 55°C)^ A+++ / A++ A++ / A++ A++ / A++
Operating Temp.
(◦C)
Ambient Air, min/max -25/43 -25/52 -25/52
Heating Flow, min/max 20/65 20/65 20/65
Flow Rates (l/m) Heating, min/max 10/20 16/30 28/60
Fluid Content (l) 1.0 1.53 2.51
Refrigerant
Type R32 R32 R32
Charge (kg) 1.30 1.70 2.00
Connections Heating Flow & Return 1” female BSP 1” female BSP 1 ¼” female BSP
*Nominal Sound Levels have been independently tested in accordance with EN 12102.
^ ErP ratings have been independently tested in accordance with EN 14825.

Page 5
Table 2 Product information
Model AS01-
R32
AS02-
R32
AS03-
R32
Air-to-water heat pump Yes
Water-to-water heat pump No
Brine-to-water heat pump No
Low-temperature heat pump No
Equipped with a supplementary heater No
Heat pump combination heater No
Symbol Value Unit
Rated heat output Prated 8 12 20 kW
Declared Capacity
of
heating for part load at indoor temp
.
20°C and outdoor temp
.,
T
j
(~ 55°C)
Tj = -7°C Pdh 3.8 7.1 9.0 kW
Tj = 2°C Pdh 2.4 4.5 5.5 kW
Tj = 7°C Pdh 2.2 4.7 7.3 kW
Tj = 12°C Pdh 2.9 5.2 7.7 kW
Tj = bivalent temperature Pdh 3.8 7.1 9.0 kW
Tj = operation limit temperature Pdh 4.4 6.3 9.3 kW
Bivalent temperature Tbiv -7 -7 -7 °C
Cycling interval capacity for heating Pcych - - - kW
Degradation coefficient Cdh - - -
Seasonal Space Heating Energy Efficiency ηs 125 126 126 %
Tj = -7°C COPd 2.12 2.20 2.23
Tj = 2°C COPd 3.01 2.98 2.90
Tj = 7°C COPd 4.04 4.34 4.54
Tj = 12°C COPd 6.70 6.42 6.39
Tj = bivalent temperature COPd 2.12 2.20 2.23
Tj = operation limit temperature COPd 1.90 1.69 1.94
Operation limit temperature TOL -10 -10 -10 °C
Cycling interval capacity for heating COPcyc
- - -
Heating water operating limit temperature WTOL 60 60 60 °C
Power consumption in modes other than active
Off mode POFF 0.013 0.060 0.020 kW
Thermostat-off mode PTO 0.013 0.060 0.020 kW
Standby mode PSB 0.013 0.060 0.020 kW
Crankcase heater mode PCK 0.043 0.069 0.106 kW
Other items
Capacity control Variable
Sound power level indoors LWA 50 51 55 dB
Annual energy consumption QHE 2739 5163 6504 kWh
Rated air flow rate - 4050 5620 8740 m3/h

Page 6
Table 3 Product Fiche
Supplier Warmflow
Warmflow Warmflow
Model AS01 AS02 AS03
Energy Efficiency Class A+++ A++ A++
Rated Heat Output (kW) 8 12 20
Seasonal Space Heating Energy Efficiency 179 158 159
Annual Energy Consumption, GCV (kWh) 1838 2750 5355
Sound Power Level, LWA (dB) 50 51 55
Rated Heat Output in Colder Climate (kW) 8 12 20
Seasonal Space Heating Energy Efficiency in Colder Climate 179 158 159
Annual Energy Consumption in Colder Climate, GCV (kWh) 2193 3159 6389
Rated Heat Output in Warmer Climate (kW) 8 12 20
Seasonal Space Heating Energy Efficiency in Warmer Climate 179 158 159
Annual Energy Consumption in Warmer Climate, GCV (kWh) 1189 1778 3463
1.4.1 Starting Current
The AS01-R32, AS02-R32 and AS03-R32 air source heat pump units are all inverter driven. This
means they ramp up slowly and therefore do not require a large starting current which is required
with fixed speed units. In the majority of situations the starting current will be less than 1Amp.
The starting current will also always be below the rated current of the unit. Below is the typical
starting profile showing the compressor frequency (left side scale) and current draw (right side
scale) from off to typical running speed.
Figure 1 Starting Current

Page 7
1.5 Construction
The Warmflow air source heat pumps are housed in a powder-coated galvanised metal casing
complete with enclosure box in which a cable entry terminal is mounted.
Figure 2 Typical Construction
Upon delivery, it is important that the unit is unpacked carefully and checked for any sign of
damage. If something is missing or damaged please report it to Warmflow immediately. The
units are secured to the shipping pallet using screws which must be removed.
NOTE: For coastal areas or other areas subjected to higher levels of corrosion, units can
be supplied with a Blygold coating applied to the evaporator to help protect it. Please
contact Warmflow for more details.
1.6 Supplied Components
Together with the unit, a number of additional components are supplied to aid installation. The
following items are supplied with each unit:
1no. Y-strainer complete with 700μm Filter Gauze
2no. 1” flexible hoses (1¼” to 1” adapter supplied with AS03)
2no. 1” Male to Female Brass Elbows
2no. 1” Isolating Ball Valves
1no. DHW Cylinder Temperature Sensor
4no. Anti-Vibration Mounts
1no. Touchscreen Controller complete with wiring and wall mount
Upon delivery, it is important to check that all components are included. If something is missing
or damaged please report it to Warmflow immediately.
Fan
Feet Supports
Front Grill
Top Lid
Wiring Entry
Points
Heating Flow
& Return
Connections

Page 8
1.7 Storage / Transport
The units come on a pallet (Dimensions of shipping sizes are shown below) and are secured to
the pallet using screws. If the units are to be stored prior to installation, they must be kept indoors
in storage conditions at a temperature of between 5°C and 60°C with a humidity level between
10%RH and 80%RH in order to provide a non-condensing environment. The units must not be
stacked in storage or during transport. During transport the units must be kept in an upright
position and should never be allowed to tilt more than 45° during loading or unloading.
Table 4 Shipping Details
Product Data AS01-R32 AS02-R32 AS03-R32
Shipping
Dimensions
(mm)
Width 1120 1090 1120
Depth 510 500 435
Height 825 920 1340
Shipping Weight (kg) 110 120 160
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Andere WarmFlow Wärmepumpe Handbücher
Beliebte Wärmepumpe Handbücher anderer Marken

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Bedienungsanleitung

Dimplex
Dimplex LI 16I-TUR Benutzerhandbuch

Carrier
Carrier WSHP Open v3 Kurzanleitung zur Einrichtung

TGM
TGM CTV14CN018A Bedienungsanleitung

Carrier
Carrier 38MGQ Series Bedienungsanleitung

Kokido
Kokido K2O K880BX/EU Fehlerbehebungshandbuch