Watchdata WD-C7808 Bedienungsanleitung

WD-C7808
Facial Recognition Thermometer
User Manual v 1.3

Content
1. Product Application Mode ........................................................................................................1
1.1 Stranger Temperature Measurement –Standalone Version...............................................1
1.2 Fixed Personnel Temperature Measurement –Standalone Version ...................................1
1.3 Online Temperature Measurement.....................................................................................1
2. Operating Instructions ..............................................................................................................2
2.1 Power On.............................................................................................................................2
2.2 Main Interface.....................................................................................................................2
2.3 Terminal-related Settings ....................................................................................................3
2.3.1 Enter System Management Interface.......................................................................3
2.3.2 Server Address Setting .............................................................................................5
2.3.3 Device Name Setting ................................................................................................5
2.3.4 Temperature Compensate Setting............................................................................6
2.3.5 List of People ............................................................................................................7
2.3.6 Historical Record Review ..........................................................................................8
2.3.7 Open/Close navigation bar.......................................................................................8
2.3.8 Networking Settings .................................................................................................9
3. Data Import/Export with USB Device......................................................................................10
3.1 Data Import .......................................................................................................................10
3.1.1 Import file Preparation...........................................................................................10
3.1.2 Saving Format of Imported File..............................................................................11
3.1.3 Data Import Operation...........................................................................................14
3.2 Data Export........................................................................................................................15
3.2.1 Insert a USB Flash Disk ...........................................................................................15
3.2.2 Export Historical Temperature Measurement Data ...............................................16
4. Terminal Mounting Methods - Desktop ..................................................................................18

1
1.Product Application Mode
1.1 Stranger Temperature Measurement –Standalone Version
Once power on, WD-C7808 Facial Recognition Thermometer (referred to as terminal) will
automatically enters into stranger temperature measurement application mode. When someone
walks into the detection zone, the terminal will automatically capture the human face, the
temperature will be displayed on the screen and broadcasted by audio. When the temperature is
above 37.3℃, there will be automatic light and audio alarm.
Applicable scenarios include public places with low flow of people, such as tax bureaus, industrial
and commercial bureaus and other government service halls, parks, banks, library, exhibition hall,
etc.
1.2 Fixed Personnel Temperature Measurement –Standalone
Version
In this application mode, the whitelist of personnel should be loaded into terminal in advance.
The terminal takes photos while measuring the temperature. The photos are compared with
those in the whitelist to determine whether they match, along with the audio broadcast. When
the temperature is above 37.3℃, there will be automatic light and audio alarm.
Whitelist import and history record export are supported by USB interface.
1.3 Online Temperature Measurement
Online temperature measurement application mode requires terminal goes online. When working
at this application mode, the terminal will not only export comparison record of whitelist, but also
do real-time uploading of stranger recognition records to server.
Online temperature measurement application mode requires a separate private deployment of the
management platform developed by Watchdata.

2
2.Operating Instructions
2.1 Power On
Insert charger in charging port at back side of terminal, the temperature measurement software
will be started automatically. It takes about 10 seconds for the boot process, please wait
patiently.
After power on of terminal, calibration with ambient temperature is required. It is recommended
to wait 10 minutes after power on before use terminal for temperature measurement.
2.2 Main Interface
After power on of terminal, the main interface is the facial recognition and temperature
measurement interface. There are 3 ICONS in the lower left corner of the display area, with the
following descriptions with their representations and functions.

3
Sound control - click this icon the volume control bar will pop up, which can be used to adjust
system volume.
Server connection status –if the dot in the icon is red, it indicates that server is not connected;
otherwise, if the dot in the icon is green, it indicates that server is connected.
Organization code modification - click to modify organization code, organization code equals to
company brand.
2.3 Terminal-related Settings
For fixed personnel temperature measurement mode and online temperature measurement
mode, terminal carries out the personnel list import and identify record export.
2.3.1 Enter System Management Interface
In the main interface of terminal, click the button in the upper right corner of the main interface
for 5 times in a row. There shows a window to enter password.

4
Enter password "6116" (default password) in the input box, click "OK" button, it should enter the
system management interface, which is displayed as below.
Click the icon in the upper right corner to quickly enter the android settings interface for related
operations.

5
2.3.2 Server Address Setting
After entering system management interface, select the "communication settings" as shown in the
following figure.
URL address - management platform address, the default is Watchdata management platform
address: 101.201.181.195:12080
Reg Code - the organization code is used to identify the company to which the device belongs. The
default value is wd-test.
Device serial number - device serial number cannot be changed by the user.
Note: the Reg Code here is consistent with the Organization code modification in the main interface.
2.3.3 Device Name Setting
After entering system management interface, select the "basic parameter settings" as shown in the
following figure.

6
Device name - user-defined device name, if user need to have multiple devices connect to the
server, device name is used for distinction.
Device gate - the default value is "Entrance", it can be set according to the actual installation
environment as Entrance, Exit or Entrance /Exit.
Installation address - equipment installation address defined by user.
2.3.4 Temperature Compensate Setting
Terminal has function of temperature compensation by certain manual calibration using a more
accurate temperature measuring device, such as a mercury thermometer.
After entering system management interface, select the "temperature settings" as shown in the
following figure.

7
Calibrate the temperature value by sliding up and down with finger for temperature compensation.
2.3.5 List of People
After entering system management interface, select the "List of people" to view the list of people
in the terminal, including white list, guest and blacklist.

8
2.3.6 Historical Record Review
After entering system management interface, select the "History" to view the history recognition
data in the terminal, which is shown as follows.
The history comparison record is displayed on the interface. Double-click to view the details of the
record.
Note: only the identification records of people on the whitelist are recorded. The identification
records of strangers are not kept.
2.3.7 Open/Close navigation bar
After entering system management interface, select the “Basic parameter settings” interface, then
“Swipe up and down to display the navigation bar” to choose whether enable this function.
Inhaltsverzeichnis